Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study

被引:8
|
作者
Klongbunjit, Disayut [1 ]
Aunmeungtong, Weerapan [1 ]
Khongkhunthian, Pathawee [1 ]
机构
[1] Chiang Mai Univ, Ctr Excellence Dent Implantol, Fac Dent, Chiang Mai 50200, Thailand
关键词
Bending moment; Removal torque; Cyclic loading; Abutment; DENTAL IMPLANT; COMPLICATION RATES; FRACTURE LOAD; FATIGUE; CROWNS; SURVIVAL; CONNECTION; RESISTANCE; TESTS;
D O I
10.1186/s40729-021-00378-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The aim of this study was to compare removal torque values after mechanical cyclic loading and bending moment after the static compression testing of customized titanium abutment compared with prefabricated and hybrid abutments. Materials and methods The study was developed according to ISO 14801:2016. Sixty implants were divided into three groups equally: Straight titanium abutment group, Customized titanium abutment group, and Hybrid zirconia abutment group. Abutments were fabricated with zirconia restoration. Forty five implants underwent for cyclic loading. The removal torque values were measured after a fatigue test was conducted at 0 cycles (control), 50,000 cycles and 1,000,000 cycles. In the second experiment, 15 implants were divided into the same groups. Then, bending moments were investigated. Results The mean initial removal torque value was significantly higher than 50,000 cycles and 1,000,000 cycles (P < 0.001). The comparison of mean removal torque value between types of abutments was not significantly different (P > 0.05), and the bending moments of all abutments were not significantly different (P > 0.05). Conclusions From the boundary of this in-vitro study, it could be concluded that customized titanium abutment and hybrid abutment were not significantly different in terms of removal torque values after the fatigue test. The bending moment between types of abutment were not significantly different. Thus, it could be concluded that abutment type does not significantly influence abutment stability or fracture strength.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Removal capability, implant-abutment connection damage and thermal effect using ultrasonic and drilling techniques for the extraction of fractured abutment screws: an in vitro study
    María Bufalá Pérez
    Álvaro Zubizarreta-Macho
    Javier Borrajo Sánchez
    Jorge Hernández Rodríguez
    Jorge Alonso Pérez-Barquero
    Elena Riad Deglow
    Sofía Hernández Montero
    BMC Oral Health, 22
  • [42] Removal capability, implant-abutment connection damage and thermal effect using ultrasonic and drilling techniques for the extraction of fractured abutment screws: an in vitro study
    Bufala Perez, Maria
    Zubizarreta-Macho, Alvaro
    Borrajo Sanchez, Javier
    Hernandez Rodriguez, Jorge
    Alonso Perez-Barquero, Jorge
    Riad Deglow, Elena
    Hernandez Montero, Sofia
    BMC ORAL HEALTH, 2022, 22 (01)
  • [43] Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study
    Sammour, Sara Reda
    El-Sheikh, Mohamed Maamoun
    El-Gendy, Attiah Aly
    DENTAL MATERIALS, 2019, 35 (11) : E265 - E271
  • [44] Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia
    Choi, Sunyoung
    Kang, Young Suk
    Yeo, In-Sung Luke
    PROSTHESIS, 2023, 5 (02): : 527 - 538
  • [45] Comparative evaluation of the wear resistance of two different implant abutment materials after cyclic loading - An in vitro study
    Ragupathi, Maniamuthu
    Mahadevan, Vallabh
    Azhagarasan, N. S.
    Ramakrishnan, Hariharan
    Jayakrishnakumar, S.
    CONTEMPORARY CLINICAL DENTISTRY, 2020, 11 (03) : 229 - 236
  • [46] Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading
    Oziunas, Rimantas
    Sakalauskiene, Jurgina
    Staisiunas, Laurynas
    Zekonis, Gediminas
    Zilinskas, Juozas
    Januzis, Gintaras
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (01): : 33 - 43
  • [47] Settling of Abutments into Implants and Changes in Removal Torque in Five Different Implant-Abutment Connections. Part 1: Cyclic Loading
    Kim, Ki-Seong
    Han, Jung-Suk
    Lim, Young-Jun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (05) : 1079 - 1084
  • [48] Misfit of Three Different Implant-Abutment Connections Before and After Cyclic Load Application: An In Vitro Study
    Gehrke, Sergio Alexandre
    Delgado-Ruiz, Rafael Arcesio
    Prados Frutos, Juan Carlos
    Prados-Privado, Maria
    Dedavid Berenice, Anina
    Granero Marin, Jose Manuel
    Calvo Guirado, Jose Luiz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 822 - 829
  • [49] Evaluation of implant abutment screw tightening protocols on reverse tightening values: An in vitro study
    Alnasser, Abdullah H.
    Wadhwani, Chandur P. K.
    Schoenbaum, Todd R.
    Kattadiyil, Mathew T.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 486 - 490
  • [50] Implant deformation and implant-abutment fracture resistance after standardized artificial aging: An in vitro study
    Zhai, Zhihao
    Tamaki, Nakano
    Chen, Yuming
    Shota, Watanabe
    Takashi, Matsuoka
    Shoichi, Ishigaki
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (01) : 107 - 117