Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study

被引:8
|
作者
Klongbunjit, Disayut [1 ]
Aunmeungtong, Weerapan [1 ]
Khongkhunthian, Pathawee [1 ]
机构
[1] Chiang Mai Univ, Ctr Excellence Dent Implantol, Fac Dent, Chiang Mai 50200, Thailand
关键词
Bending moment; Removal torque; Cyclic loading; Abutment; DENTAL IMPLANT; COMPLICATION RATES; FRACTURE LOAD; FATIGUE; CROWNS; SURVIVAL; CONNECTION; RESISTANCE; TESTS;
D O I
10.1186/s40729-021-00378-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The aim of this study was to compare removal torque values after mechanical cyclic loading and bending moment after the static compression testing of customized titanium abutment compared with prefabricated and hybrid abutments. Materials and methods The study was developed according to ISO 14801:2016. Sixty implants were divided into three groups equally: Straight titanium abutment group, Customized titanium abutment group, and Hybrid zirconia abutment group. Abutments were fabricated with zirconia restoration. Forty five implants underwent for cyclic loading. The removal torque values were measured after a fatigue test was conducted at 0 cycles (control), 50,000 cycles and 1,000,000 cycles. In the second experiment, 15 implants were divided into the same groups. Then, bending moments were investigated. Results The mean initial removal torque value was significantly higher than 50,000 cycles and 1,000,000 cycles (P < 0.001). The comparison of mean removal torque value between types of abutments was not significantly different (P > 0.05), and the bending moments of all abutments were not significantly different (P > 0.05). Conclusions From the boundary of this in-vitro study, it could be concluded that customized titanium abutment and hybrid abutment were not significantly different in terms of removal torque values after the fatigue test. The bending moment between types of abutment were not significantly different. Thus, it could be concluded that abutment type does not significantly influence abutment stability or fracture strength.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Implications of Wear at the Titanium-Zirconia Implant-Abutment Interface on the Health of Peri-implant Tissues
    Tawse-Smith, Andrew
    Ma, Sunyoung
    Duncan, Warwick J.
    Gray, Andrew
    Reid, Malcolm R.
    Rich, Alison M.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (03) : 599 - 609
  • [32] Removal Torque and Biofilm Accumulation at Two Dental Implant-Abutment Joints After Fatigue
    Pereira, Jorge
    Morsch, Carolina S.
    Henriques, Bruno
    Nascimento, Rubens M.
    Benfatti, Cesar A. M.
    Silva, Filipe S.
    Lopez-Lopez, Jose
    Souza, Julio C. M.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : 813 - 819
  • [33] Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
    Yi, Yuseung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (06): : 305 - 312
  • [34] Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation
    Truninger, Thomas C.
    Stawarczyk, Bogna
    Leutert, Christian R.
    Sailer, Thomas R.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (01) : 12 - 18
  • [35] Er:YAG laser removal of zirconia crowns on titanium abutment of dental implants: an in vitro study
    Pingping Cai
    Yingying Zhuo
    Jie Lin
    Zhiqiang Zheng
    BMC Oral Health, 22
  • [36] Er:YAG laser removal of zirconia crowns on titanium abutment of dental implants: an in vitro study
    Cai, Pingping
    Zhuo, Yingying
    Lin, Jie
    Zheng, Zhiqiang
    BMC ORAL HEALTH, 2022, 22 (01)
  • [37] Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants
    Mohammed, Hnd Hadi
    Lee, Jin-Han
    Bae, Ji-Myung
    Cho, Hye-Won
    JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (01): : 62 - 69
  • [38] Stability of Implant-Abutment Connection After Using the Rescue Kit: An In Vitro Study
    Sprenger, Achim
    Gutauskas, Kristupas
    Filippi, Andreas
    Rosentritt, Martin
    Kuehl, Sebastian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1274 - 1278
  • [39] Manual closing torque in five implant abutment systems: An in vitro comparative study
    Gross, M
    Kozak, D
    Laufer, BZ
    Weiss, EI
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (05): : 574 - 578
  • [40] Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study
    Ahmed, Syed Ershad
    Krishnan, Chitra Shankar
    Mohan, Jayashree
    Kalaignan, Parithimar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (02)