Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam

被引:3
|
作者
Zhang Lu-Lu [1 ]
Bai Le-Le [1 ]
Yang Yu-Lin [1 ]
Yang Yong-Biao [1 ]
Wang Yan-Hua [1 ,3 ,5 ]
Wen Xin [1 ,4 ]
He Jun [1 ,2 ,5 ]
Wang Jun-Min [1 ,2 ,5 ]
机构
[1] Shanxi Univ, Inst Optoelect, State Key Lab Quantum Opt & Quantum Opt Decices, Taiyuan 030006, Peoples R China
[2] Shanxi Univ, Sch Phys & Elect Engn, Dept Phys, Taiyuan 030006, Peoples R China
[3] Shanxi Univ, Sch Phys & Elect Engn, Dept Optoectron Engn, Taiyuan 030006, Peoples R China
[4] Tsinghua Univ, Dept Phys, Beijing 100084, Peoples R China
[5] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
optically pumped rubidium atomic magnetometer; linewidth of magnetic resonance signal; signal-to-noise ratio; repumping light; fluxgate magnetometer's calibration;
D O I
10.7498/aps.70.20210920
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of similar to 1.2 kHz, and the sensitivity is calibrated to be similar to 245.5 pT/Hz(1/2) only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be similar to 26.4 pT/Hz(1/2) which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.
引用
收藏
页数:11
相关论文
共 25 条
  • [21] Research on an pump-probe rubidium magnetometer
    Wang Zhi-Guo
    Luo Hui
    Fan Zhen-Fang
    Xie Yuan-Ping
    [J]. ACTA PHYSICA SINICA, 2016, 65 (21)
  • [22] Single-Species Atomic Comagnetometer Based on 87Rb Atoms
    Wang, Zhiguo
    Peng, Xiang
    Zhang, Rui
    Luo, Hui
    Li, Jiajia
    Xiong, Zhiqiang
    Wang, Shanshan
    Guo, Hong
    [J]. PHYSICAL REVIEW LETTERS, 2020, 124 (19)
  • [23] Manipulation of spin polarization of rubidium atoms by optical pumping with both D1 and D2 beams
    Yang, Hongying
    Wang, Yanhua
    Zhao, Nan
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2020, 74 (11):
  • [24] Recording brain activities in unshielded Earth's field with optically pumped atomic magnetometers
    Zhang, Rui
    Xiao, Wei
    Ding, Yudong
    Feng, Yulong
    Peng, Xiang
    Shen, Liang
    Sun, Chenxi
    Wu, Teng
    Wu, Yulong
    Yang, Yucheng
    Zheng, Zhaoyu
    Zhang, Xiangzhi
    Chen, Jingbiao
    Guo, Hong
    [J]. SCIENCE ADVANCES, 2020, 6 (24)
  • [25] A vector atomic magnetometer based on the spin self-sustaining Larmor method
    Zhao, Q.
    Fan, B. L.
    Wang, S. G.
    Wang, L. J.
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2019, 481 : 257 - 261