Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam

被引:3
|
作者
Zhang Lu-Lu [1 ]
Bai Le-Le [1 ]
Yang Yu-Lin [1 ]
Yang Yong-Biao [1 ]
Wang Yan-Hua [1 ,3 ,5 ]
Wen Xin [1 ,4 ]
He Jun [1 ,2 ,5 ]
Wang Jun-Min [1 ,2 ,5 ]
机构
[1] Shanxi Univ, Inst Optoelect, State Key Lab Quantum Opt & Quantum Opt Decices, Taiyuan 030006, Peoples R China
[2] Shanxi Univ, Sch Phys & Elect Engn, Dept Phys, Taiyuan 030006, Peoples R China
[3] Shanxi Univ, Sch Phys & Elect Engn, Dept Optoectron Engn, Taiyuan 030006, Peoples R China
[4] Tsinghua Univ, Dept Phys, Beijing 100084, Peoples R China
[5] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
optically pumped rubidium atomic magnetometer; linewidth of magnetic resonance signal; signal-to-noise ratio; repumping light; fluxgate magnetometer's calibration;
D O I
10.7498/aps.70.20210920
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of similar to 1.2 kHz, and the sensitivity is calibrated to be similar to 245.5 pT/Hz(1/2) only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be similar to 26.4 pT/Hz(1/2) which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.
引用
收藏
页数:11
相关论文
共 25 条
  • [1] BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
  • [2] Non destructive evaluation of advanced composite materials for aerospace application using HTS SQUIDs
    Bonavolonta, C.
    Valentino, A.
    Peluso, G.
    Barone, A.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 772 - 775
  • [3] Moving magnetoencephalography towards real-world applications with a wearable system
    Boto, Elena
    Holmes, Niall
    Leggett, James
    Roberts, Gillian
    Shah, Vishal
    Meyer, Sofie S.
    Munoz, Leonardo Duque
    Mullinger, Karen J.
    Tierney, Tim M.
    Bestmann, Sven
    Barnes, Gareth R.
    Bowtell, Richard
    Brookes, Matthew J.
    [J]. NATURE, 2018, 555 (7698) : 657 - +
  • [4] Budker D., 2013, OPTICAL MAGNETOMETRY
  • [5] Optical magnetometry
    Budker, Dmitry
    Romalis, Michael
    [J]. NATURE PHYSICS, 2007, 3 (04) : 227 - 234
  • [6] Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
    Dang, H. B.
    Maloof, A. C.
    Romalis, M. V.
    [J]. APPLIED PHYSICS LETTERS, 2010, 97 (15)
  • [7] Three-dimensional atomic magnetometry
    Dong, H. F.
    Fang, J. C.
    Zhou, B. Q.
    Tang, X. B.
    Qin, J.
    [J]. EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2012, 57 (02):
  • [8] Study on sensitivity-related parameters of distributed feedback laser-pumped cesium atomic magnetometer
    Gu Yuan
    Shi Rong-Ye
    Wang Yan-Hui
    [J]. ACTA PHYSICA SINICA, 2014, 63 (11)
  • [9] Keaveney J, 2013, THESIS DURHAM U DURH
  • [10] Magnetoencephalography With Optically Pumped 4He Magnetometers at Ambient Temperature
    Labyt, Etienne
    Corsi, Marie-Constance
    Fourcault, William
    Laloy, Augustin Palacios
    Bertrand, Francois
    Lenouvel, Francois
    Cauffet, Gilles
    Le Prado, Matthieu
    Berger, Francois
    Morales, Sophie
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (01) : 90 - 98