The Accuracy of Intraoperative O-arm Images for the Assessment of Pedicle Screw Postion

被引:67
|
作者
Santos, Edward R. G. [1 ]
Ledonio, Charles G. [1 ]
Castro, Carlos A. [1 ]
Truong, Walter H. [1 ]
Sembrano, Jonathan N. [1 ]
机构
[1] Univ Minnesota, Dept Orthopaed, Minneapolis, MN 55454 USA
关键词
intraoperative imaging; pedicle screws; screw revision; COMPUTED-TOMOGRAPHY; PLACEMENT; FIXATION; COMPLICATIONS; RELIABILITY; AGREEMENT;
D O I
10.1097/BRS.0b013e3182257cae
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Human cadaveric study. Objective. The objective of the study was to determine the accuracy of intraoperative O-arm images in determining pedicle screw position using open dissection as the gold standard. Summary of Background Data. Pedicle screws are widely used in the treatment of various spinal disorders. Postoperative computed tomographic scans are the imaging gold standard to detect pedicle screw malposition. However, a second procedure is necessary if such malpositioned screws have to be revised. The O-arm is an intraoperative scanner that allows revision of a screw without having to return the patient to the operating room for a separate procedure. No previous studies have looked at the accuracy of intraoperative O-arm images in determining pedicle screw position. Methods. This factorial validation study utilized 9 cadavers in a comparison of intraoperative O-arm images and the dissection gold standard. Four hundred sixteen screws were inserted using 3-dimensional image (O-arm) guidance from C2 to S1. The screw positions were randomized into 3 groups: "IN" (fully contained within the pedicle), "OUT-lateral," or "OUT-medial." After screw insertion, O-arm images were obtained and reviewed in a blinded fashion by 3 independent observers. Dissection identified the true position of the screws. Specificity, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using dissection results as the gold standard. The interobserver reliability was also determined. Results. The overall accuracy, specificity, sensitivity, PPV, and NPV of O-arm images for the thoracic and lumbar spine were 73%, 76%, 71%, 74%, and 72%, respectively. Accuracy of surgeon perception in the cervical spine was significantly less than in the thoracic and lumbosacral spine. There was substantial interobserver agreement between the 3 readers. Conclusion. Intraoperative O-arm images accurately detect significant pedicle screw violations in the thoracic and lumbosacral spine but are less accurate for the cervical spine.
引用
收藏
页码:E119 / E125
页数:7
相关论文
共 50 条
  • [31] Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique
    Mengran Jin
    Zhen Liu
    Xingyong Liu
    Huang Yan
    Xiao Han
    Yong Qiu
    Zezhang Zhu
    European Spine Journal, 2016, 25 : 1729 - 1737
  • [32] Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique
    Jin, Mengran
    Liu, Zhen
    Liu, Xingyong
    Yan, Huang
    Han, Xiao
    Qiu, Yong
    Zhu, Zezhang
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1729 - 1737
  • [33] No O-Arm? No Problem-Carrying On Odontoid Screw Fixation
    Gupta, Vijay Kumar
    Carvalho, Ajay Sebastian
    Shekhawat, Nagendra Singh
    Gupta, Ekata
    NEUROLOGY INDIA, 2024, 72 (03) : 673 - 674
  • [34] Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures
    Takeba J.
    Umakoshi K.
    Kikuchi S.
    Matsumoto H.
    Annen S.
    Moriyama N.
    Nakabayashi Y.
    Sato N.
    Aibiki M.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (3) : 431 - 438
  • [35] Learning curve across 2000 thoracolumbar pedicle screw placements using O-arm navigation: technical difficulties and their solutions
    Shailesh Hadgaonkar
    Alok Gupta
    Siddharth Aiyer
    Pramod Bhilare
    Parag Sancheti
    European Spine Journal, 2023, 32 : 3753 - 3763
  • [36] Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy
    Ling, Ji Min
    Dinesh, Shree Kumar
    Pang, Boon Chuan
    Chen, Min Wei
    Lim, Heng Lip
    Louange, Danny T.
    Yu, Chun Sing
    Wang, Chee Meng Ernest
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (03) : 493 - 498
  • [37] Learning curve across 2000 thoracolumbar pedicle screw placements using O-arm navigation: technical difficulties and their solutions
    Hadgaonkar, Shailesh
    Gupta, Alok
    Aiyer, Siddharth
    Bhilare, Pramod
    Sancheti, Parag
    EUROPEAN SPINE JOURNAL, 2023, 32 (11) : 3753 - 3763
  • [38] Surgical Technique and Accuracy of S2 Alar-Iliac Screw Insertion Using Intraoperative O-Arm Navigation: An Analysis of 120 Screws
    Tamaki, Ryo
    Wada, Keiji
    Okazaki, Ken
    WORLD NEUROSURGERY, 2020, 144 : E326 - E330
  • [39] Technical Accuracy of an O-Arm Registered Surgical Navigator
    Koivukangas, Tapani
    Katisko, Jani P. A.
    Koivukangas, John P.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2148 - 2151
  • [40] O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis
    Weili Feng
    Weihao Wang
    Shubiao Chen
    Kezhou Wu
    Hu Wang
    International Orthopaedics, 2020, 44 : 919 - 926