The Accuracy of Intraoperative O-arm Images for the Assessment of Pedicle Screw Postion

被引:67
|
作者
Santos, Edward R. G. [1 ]
Ledonio, Charles G. [1 ]
Castro, Carlos A. [1 ]
Truong, Walter H. [1 ]
Sembrano, Jonathan N. [1 ]
机构
[1] Univ Minnesota, Dept Orthopaed, Minneapolis, MN 55454 USA
关键词
intraoperative imaging; pedicle screws; screw revision; COMPUTED-TOMOGRAPHY; PLACEMENT; FIXATION; COMPLICATIONS; RELIABILITY; AGREEMENT;
D O I
10.1097/BRS.0b013e3182257cae
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Human cadaveric study. Objective. The objective of the study was to determine the accuracy of intraoperative O-arm images in determining pedicle screw position using open dissection as the gold standard. Summary of Background Data. Pedicle screws are widely used in the treatment of various spinal disorders. Postoperative computed tomographic scans are the imaging gold standard to detect pedicle screw malposition. However, a second procedure is necessary if such malpositioned screws have to be revised. The O-arm is an intraoperative scanner that allows revision of a screw without having to return the patient to the operating room for a separate procedure. No previous studies have looked at the accuracy of intraoperative O-arm images in determining pedicle screw position. Methods. This factorial validation study utilized 9 cadavers in a comparison of intraoperative O-arm images and the dissection gold standard. Four hundred sixteen screws were inserted using 3-dimensional image (O-arm) guidance from C2 to S1. The screw positions were randomized into 3 groups: "IN" (fully contained within the pedicle), "OUT-lateral," or "OUT-medial." After screw insertion, O-arm images were obtained and reviewed in a blinded fashion by 3 independent observers. Dissection identified the true position of the screws. Specificity, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using dissection results as the gold standard. The interobserver reliability was also determined. Results. The overall accuracy, specificity, sensitivity, PPV, and NPV of O-arm images for the thoracic and lumbar spine were 73%, 76%, 71%, 74%, and 72%, respectively. Accuracy of surgeon perception in the cervical spine was significantly less than in the thoracic and lumbosacral spine. There was substantial interobserver agreement between the 3 readers. Conclusion. Intraoperative O-arm images accurately detect significant pedicle screw violations in the thoracic and lumbosacral spine but are less accurate for the cervical spine.
引用
收藏
页码:E119 / E125
页数:7
相关论文
共 50 条
  • [21] Surgical Results of Intraoperative C-arm Fluoroscopy Versus O-arm in Transarticular Screw Fixation for Atlantoaxial Instability
    Wada, Keiji
    Inoue, Tomohisa
    Hagiwara, Kenji
    Tamaki, Ryo
    Okazaki, Ken
    WORLD NEUROSURGERY, 2020, 139 : E686 - E690
  • [22] Intraoperative O-arm Use for Physeal Bar Excision
    Richard, Brian
    Abbas, Mohammed
    Odeneye, Oluwatobi
    Turker, Tolga
    TECHNIQUES IN ORTHOPAEDICS, 2024, 39 (04) : 111 - 118
  • [23] Transpedicular Screw Placement Accuracy Using the O-Arm Versus Freehand Technique at a Single Institution
    Crawford, Benjamin D.
    Nchako, Corbyn M.
    Rebehn, Kelsey A.
    Israel, Heidi
    Place, Howard M.
    GLOBAL SPINE JOURNAL, 2022, 12 (03) : 447 - 451
  • [24] Metal artifacts in intraoperative O-arm CBCT scans
    Juha I. Peltonen
    Touko Kaasalainen
    Mika Kortesniemi
    BMC Medical Imaging, 21
  • [25] Comparison of the Wiltse Approach and Percutaneous Pedicle Screw Fixation Under O-arm Navigation for the Treatment of Thoracolumbar Fractures
    Lu, Ying-jie
    Miao, Yi-ming
    Zhu, Tian-feng
    Wu, Qian
    Shen, Xu
    Lu, Dong-dong
    Zhu, Xue-song
    Gan, Min-feng
    ORTHOPAEDIC SURGERY, 2021, 13 (05) : 1618 - 1627
  • [26] Application of the O-arm Intraoperative Imaging System to Assist Anterior Cervical Screw Fixation for Odontoid Fractures
    Zhao, Ruoyu
    Ding, Wenyuan
    Li, Xiangyu
    Han, Felicity Y.
    Yang, Dalong
    Yang, Sidong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (186):
  • [27] Metal artifacts in intraoperative O-arm CBCT scans
    Peltonen, Juha I.
    Kaasalainen, Touko
    Kortesniemi, Mika
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [28] Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines: Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods
    Shin, Myung-Hoon
    Ryu, Kyeong-Sik
    Park, Chun-Kun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 52 (03) : 204 - 209
  • [29] O-arm Versus C-arm: Comparison of the Learning Curves and Accuracy in Transpedicular Screw Fixation of Lumbar Spondylolisthesis
    Jablonsky, J.
    Trnka, S.
    Stejskal, P.
    Hrabalek, L.
    Wanek, T.
    Vaverka, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2024, 91 (06) : 355 - 363
  • [30] Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients
    Ravindra, Vijay M.
    Kalra, Ricky R.
    Dailey, Andrew T.
    SPINE JOURNAL, 2019, 19 (02): : 206 - 211