Refractive and Visual Outcomes After Intacs vs Ferrara Intrastromal Corneal Ring Segment Implantation for Keratoconus: A Comparative Study

被引:29
|
作者
Kaya, Vedat [2 ]
Utine, Canan Asli [1 ]
Karakus, Sezen Harmanci [2 ]
Kavadarli, Isilay [2 ]
Yilmaz, Omer Faruk [2 ]
机构
[1] Yeditepe Univ, Dept Ophthalmol, TR-34345 Istanbul, Turkey
[2] Beyoglu Eye Res & Training Hosp, Istanbul, Turkey
关键词
TERM-FOLLOW-UP; FEMTOSECOND LASER; MANAGEMENT; MODERATE; PERFORMANCE; EFFICACY; MODELS;
D O I
10.3928/1081597X-20110906-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the refractive, topographic, optical, visual acuity, and quality outcomes of two types of intrastromal corneal ring segments (ICRS) in the treatment of keratoconus. METHODS: In this retrospective study, 16 eyes that had been implanted with Intacs ICRS (Addition Technology Inc) (Intacs group) and 17 eyes implanted with Ferrara ICRS (Ferrara Ophthalmics Ltda) (Ferrara group) were evaluated. Pre- and postoperative examinations included uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), manifest refraction, slit-lamp examination, topography, and ocular wavefront analysis. Contrast sensitivity measurements under photopic, scotopic, and scotopic with glare conditions were performed 1 year postoperatively. RESULTS: One year postoperatively, a significant decrease was noted in spherical equivalent refractive error of 3.76 +/- 0.39 diopters (D) and 3.42 +/- 0.88 D and keratometry of 3.43 +/- 0.24 D and 3.28 +/- 0.78 D in the Intacs and Ferrara groups, respectively; and increase in mean UDVA and CDVA in Snellen lines of 0.18 +/- 0.04 and 0.21 +/- 0.05, respectively, in the Intacs group and 0.21 +/- 0.09 and 0.26 +/- 0.08, respectively, in the Ferrara group (P<.01 for all). The postoperative increase in UDVA and CDVA and decrease in keratometry readings were not significantly different between groups (P>.05 for all). Mean higher order aberrations decreased in the Intacs group and increased in the Ferrara group (P>.05 for both). Postoperatively, a signifi cant decrease was noted in scotopic contrast sensitivity when glare was introduced in the Ferrara group, which was positively correlated with pupil diameter (r(15)= 0.50, P=.04). CONCLUSIONS: Both ICRS types provided comparable refractive, topographic, and optical quality outcomes. Eyes with Ferrara ICRS experienced greater decrease in scotopic contrast sensitivity under glare, which was significantly correlated with pupil diameter. [J Refract Surg. 2011; 27(12): 907-912.] doi:10.3928/1081597X-20110906-03
引用
收藏
页码:907 / 912
页数:6
相关论文
共 50 条
  • [1] INTACS Followed by KeraRing Intrastromal Corneal Ring Segment Implantation for Keratoconus
    Coskunseven, Efekan
    Kymionis, George D.
    Grentzelos, Michael A.
    Karavitaki, Alexandra E.
    Portaliou, Dimitra M.
    Jankov, Mirko R., II
    Arslan, Ebru
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 371 - 374
  • [2] Tomographic Findings After Implantation of Ferrara Intrastromal Corneal Ring Segments in Keratoconus
    Lyra, Joao Marcelo
    Lyra, Daniela
    Ribeiro, Guilherme
    Torquetti, Leonardo
    Ferrara, Paulo
    Machado, Aydano
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (02) : 110 - +
  • [3] Visual and Refractive Outcomes and Tomographic Changes after Femtosecond Laser-assisted Intrastromal Corneal Ring Segment Implantation in Patients with Keratoconus
    Hashemian, Seyed Javad
    Farshchian, Nooshin
    Foroutam-Jazi, Alireza
    Jafari, Mohammad Ebrahim
    Hashemian, Mahsa Sadat
    Hashemian, Seyed Mahyar
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (04) : 376 - 382
  • [4] Acute corneal hydrops after intrastromal corneal ring segment implantation for keratoconus
    Gueell, Jose L.
    Verdaguer, Paula
    Elies, Daniel
    Gris, Oscar
    Manero, Felicidad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2192 - 2195
  • [5] Intrastromal Corneal Ring Segment Implantation for the Treatment of Keratoconus
    Kubaloglu, Anil
    Sari, Esin Sogutlu
    Cinar, Yasin
    Koytak, Arif
    Kurnaz, Ekrem
    Ozerturk, Yusuf
    CORNEA, 2011, 30 (01) : 11 - 17
  • [6] Corneal densitometry in patients with keratoconus undergoing intrastromal Ferrara ring implantation
    Rodrigues, Pablo Felipe
    Moscovici, Bernardo Kaplan
    Ferrara, Guilherme
    Lamazales, Luciano
    Freitas, Marcela Mara Silva
    Torquetti, Leonardo
    Ambrosio, Renato
    Gomes, Jose Alvaro Pereira
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 3505 - 3510
  • [7] Intrastromal corneal ring segments: effect of depth of implantation in visual, refractive, and topographic outcomes in patients with keratoconus
    Cruz, Carlos Neves
    Franqueira, Nuno
    Mendes, Jose Carlos
    Oliveira, Mariana
    Monteiro, Tiago
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (09): : 949 - 955
  • [8] Intrastromal corneal ring segment implantation for ectasia after refractive surgery
    Souza Stival, Larissa Rossana
    do Amaral Nassaralla, Belquiz R.
    Falleiro Chaves de Figueiredo, Marisa Novaes
    Bicalho, Frederico
    Nassaralla Junior, Joao Jorge
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (04) : 212 - 215
  • [9] INTRASTROMAL CORNEAL RING SEGMENT IMPLANTATION FOR ECTASIA AFTER REFRACTIVE SURGERY
    Stival, Larissa Rossana
    Nassaralla, Belquiz A.
    Figueiredo, Marisa
    Bicalho, Frederico
    Nassaralla, Joao J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [10] Intrastromal corneal ring segment implantation for ectasia after refractive surgery
    Torquetti, Leonardo
    Ferrara, Paulo