Automatic orbital computed tomography coordinating method and quantitative error evaluation based on signed distance field

被引:8
|
作者
Zhai, Guangtao [1 ]
Yin, Ziqing [2 ,3 ]
Li, Lunhao [2 ,3 ]
Song, Xuefei [2 ,3 ]
Zhou, Yixiong [2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Image Commun & Network Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Peoples Hosp 9, Dept Ophthalmol, Shanghai, Peoples R China
[3] Shanghai Key Lab Orbital Dis & Ocular Oncol, Shanghai, Peoples R China
基金
国家重点研发计划;
关键词
Orbital computed tomography; automatic coordination; signed distance field; quantitative evaluation; VOLUME MEASUREMENT;
D O I
10.1177/0284185120914029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Orbital computed tomography (CT) is commonly used for the diagnosis and digital evaluation of orbital diseases. Yet, this approach requires longer scanning time, increased radiation exposure, and, especially, difficult patient positioning that can affect judgment and data processing. According to high-quality research on orbital imaging, computer-assisted surgery, and artificial intelligent diagnostic development, the correction of a coordinate system is a necessary procedure. Nevertheless, existing manual calibration methods are challenging to reproduce and there is no objective evaluation system for errors. Purpose To establish a method for automatic calibration of orbital CT images and implementation of quantitative error evaluation. Material and Methods A standard three-dimensional (3D) orbit model was manually adjusted, and optimized orbital models were reconstructed based on the initial registration of the skull-bound directed bounding box and the registration of the mutual information method. The calibration error was calculated based on the signed distance field. Seventeen cases of orbital CT were quantitatively evaluated. Results A new method for automatic calibration and quantitative error evaluation for orbital CT was established. The calibrated model error with +/- 2 mm accounted for 81.61% +/- 6.91% of the total models, and the error of +/- 1 mm accounted for 53.49% +/- 7.07% of the total models. Conclusion This convenient tool for orbital CT automatic calibration may promote the related quantitative research based on orbital CT. The automated operation and small error are beneficial to the popularization and application of the tool, and the quantitative evaluation facilitates other coordinate systems.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [31] Automatic Quantitative Micro-Computed Tomography Evaluation of Angiogenesis in an Axially Vascularized Tissue-Engineered Bone Construct
    Arkudas, Andreas
    Beier, Justus Patrick
    Pryymachuk, Galyna
    Hoereth, Tobias
    Bleiziffer, Oliver
    Polykandriotis, Elias
    Hess, Andreas
    Gulle, Heinz
    Horch, Raymund E.
    Kneser, Ulrich
    TISSUE ENGINEERING PART C-METHODS, 2010, 16 (06) : 1503 - 1514
  • [32] A Quantitative Evaluation Method for Nonstationarity of Training Image Based on Pattern Tiles Distance
    Yu, Siyu
    Li, Shaohua
    Dou, Mengjiao
    Su, Linye
    LITHOSPHERE, 2022, 2022 (SpecialIssue13)
  • [33] Quantitative evaluation of chronically obstructed kidneys from noncontrast computed tomography based on deep learning
    Sun Zhaonan
    Cui Yingpu
    Liu Xiang
    Lin Zhiyong
    Liu Weipeng
    Wang Xiangpeng
    Zhang Jingyuan
    Zhang Xiaodong
    Wang Xiaoying
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [34] Evaluation for Performance of Body Composition Index Based on Quantitative Computed Tomography in the Prediction of Metabolic Syndrome
    Li, Cuihong
    Xu, Bingwu
    Chen, Mengxue
    Zhang, Yong
    METABOLIC SYNDROME AND RELATED DISORDERS, 2024, 22 (04) : 287 - 294
  • [35] Quantitative evaluation of single-photon emission computed tomography findings in lower extremity possible without computed tomography-based attenuation correction
    Tsuchitani, Tatsuya
    Kitajima, Kazuhiro
    Takahashi, Yoshiyuki
    Kotoura, Noriko
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (10) : 1097 - 1103
  • [36] Neural network-based method for diagnosis and severity assessment of Graves' orbitopathy using orbital computed tomography
    Lee, Jaesung
    Seo, Wangduk
    Park, Jaegyun
    Lim, Won-Seon
    Oh, Ja Young
    Moon, Nam Ju
    Lee, Jeong Kyu
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [37] Neural network-based method for diagnosis and severity assessment of Graves’ orbitopathy using orbital computed tomography
    Jaesung Lee
    Wangduk Seo
    Jaegyun Park
    Won-Seon Lim
    Ja Young Oh
    Nam Ju Moon
    Jeong Kyu Lee
    Scientific Reports, 12
  • [38] Siltation behavior characterization and evaluation of permeable asphalt mixture based on computed tomography method
    An, Yin
    Du, Lizhi
    Dai, Wenting
    Zhang, Kai
    Huang, Mingxing
    Guo, Wei
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 411
  • [39] Attitude angle field accuracy evaluation method based on space distance constraints
    Liu N.
    Xiong Z.
    He J.
    Zhai Z.
    Zhou W.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (09): : 72 - 80
  • [40] A mathematical method to estimate angle and distance for percutaneous renal puncture based on computed tomography data: Description and validation
    Salem, Shady Mohamed
    Aldousari, Saad A.
    UROLOGY ANNALS, 2023, 15 (02) : 197 - 201