Automatic orbital computed tomography coordinating method and quantitative error evaluation based on signed distance field

被引:8
|
作者
Zhai, Guangtao [1 ]
Yin, Ziqing [2 ,3 ]
Li, Lunhao [2 ,3 ]
Song, Xuefei [2 ,3 ]
Zhou, Yixiong [2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Image Commun & Network Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Peoples Hosp 9, Dept Ophthalmol, Shanghai, Peoples R China
[3] Shanghai Key Lab Orbital Dis & Ocular Oncol, Shanghai, Peoples R China
基金
国家重点研发计划;
关键词
Orbital computed tomography; automatic coordination; signed distance field; quantitative evaluation; VOLUME MEASUREMENT;
D O I
10.1177/0284185120914029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Orbital computed tomography (CT) is commonly used for the diagnosis and digital evaluation of orbital diseases. Yet, this approach requires longer scanning time, increased radiation exposure, and, especially, difficult patient positioning that can affect judgment and data processing. According to high-quality research on orbital imaging, computer-assisted surgery, and artificial intelligent diagnostic development, the correction of a coordinate system is a necessary procedure. Nevertheless, existing manual calibration methods are challenging to reproduce and there is no objective evaluation system for errors. Purpose To establish a method for automatic calibration of orbital CT images and implementation of quantitative error evaluation. Material and Methods A standard three-dimensional (3D) orbit model was manually adjusted, and optimized orbital models were reconstructed based on the initial registration of the skull-bound directed bounding box and the registration of the mutual information method. The calibration error was calculated based on the signed distance field. Seventeen cases of orbital CT were quantitatively evaluated. Results A new method for automatic calibration and quantitative error evaluation for orbital CT was established. The calibrated model error with +/- 2 mm accounted for 81.61% +/- 6.91% of the total models, and the error of +/- 1 mm accounted for 53.49% +/- 7.07% of the total models. Conclusion This convenient tool for orbital CT automatic calibration may promote the related quantitative research based on orbital CT. The automated operation and small error are beneficial to the popularization and application of the tool, and the quantitative evaluation facilitates other coordinate systems.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [21] An Image Evaluation Method for Electrical Impedance Tomography Based on Gradient Error
    Lv Jinghua
    Gong Weiyan
    Wang Yan
    Ren Chaoshi
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2419 - +
  • [22] Quantitative evaluation of a cone-beam computed tomography-planning computed tomography deformable image registration method for adaptive radiation therapy
    Lawson, Joshua D.
    Schreibmann, Eduard
    Jani, Ashesh B.
    Fox, Tim
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 96 - 113
  • [23] Evaluation of deep learning-based quantitative computed tomography for opportunistic osteoporosis screening
    Oh, Sangseok
    Kang, Woo Young
    Park, Heejun
    Yang, Zepa
    Lee, Jemyoung
    Kim, Changwon
    Woo, Ok Hee
    Hong, Suk-Joo
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [24] Automatic Quantitative Computed Tomography Evaluation of the Lungs in Patients With Systemic Sclerosis Treated With Autologous Stem Cell Transplantation
    Wada, Danilo Tadao
    de Almeida, Fabricio Arantes
    de Moraes, Daniela Aparecida
    Elias Dias, Juliana Bernardes
    Baddini-Martinez, Jose
    Oliveira, Maria Carolina
    Koenigkam-Santos, Marcel
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2020, 26 : S158 - S164
  • [25] Evaluation of deep learning-based quantitative computed tomography for opportunistic osteoporosis screening
    Sangseok Oh
    Woo Young Kang
    Heejun Park
    Zepa Yang
    Jemyoung Lee
    Changwon Kim
    Ok Hee Woo
    Suk-Joo Hong
    Scientific Reports, 14
  • [26] A robust and semi-automatic quantitative measurement of patellofemoral instability based on four dimensional computed tomography
    Chen, Hao
    Kluijtmans, Leo
    Bakker, Max
    Dunning, Hans
    Kang, Yan
    van de Groes, Sebastiaan
    Sprengers, Andre M. J.
    Verdonschot, Nico
    MEDICAL ENGINEERING & PHYSICS, 2020, 78 (78) : 29 - 38
  • [27] A Method to Evaluate the Reduction Difficulty of Atlantoaxial Dislocation Based on Computed Tomography Quantitative Analysis
    Wang, Jianhua
    Yang, Haozhi
    Chen, Yuyue
    Liu, Guoqiang
    Xie, Ningling
    Zhang, Shuang
    Qiao, Guoqing
    WORLD NEUROSURGERY, 2024, 185 : E283 - E290
  • [28] Morphometric evaluation of the anatomical relationships between the superior orbital fissure and the orbital structures based on computed tomography images with clinical implications
    Erbek, Esin
    Cicekcibasi, Aynur Emine
    Acar, Guelay
    Digilli Ayas, Betuel
    Aydogdu, Demet
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [29] Quantitative grating-based x-ray dark-field computed tomography
    Wang, Zhen-Tian
    Kang, Ke-Jun
    Huang, Zhi-Feng
    Chen, Zhi-Qiang
    APPLIED PHYSICS LETTERS, 2009, 95 (09)
  • [30] A computer-based method for calculation of orbital floor fractures from coronal computed tomography scans
    Ploder, O
    Klug, C
    Voracek, M
    Backfrieder, W
    Tschabitscher, M
    Czerny, C
    Baumann, A
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (12) : 1437 - 1442