Automatic orbital computed tomography coordinating method and quantitative error evaluation based on signed distance field

被引:8
|
作者
Zhai, Guangtao [1 ]
Yin, Ziqing [2 ,3 ]
Li, Lunhao [2 ,3 ]
Song, Xuefei [2 ,3 ]
Zhou, Yixiong [2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Image Commun & Network Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Peoples Hosp 9, Dept Ophthalmol, Shanghai, Peoples R China
[3] Shanghai Key Lab Orbital Dis & Ocular Oncol, Shanghai, Peoples R China
基金
国家重点研发计划;
关键词
Orbital computed tomography; automatic coordination; signed distance field; quantitative evaluation; VOLUME MEASUREMENT;
D O I
10.1177/0284185120914029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Orbital computed tomography (CT) is commonly used for the diagnosis and digital evaluation of orbital diseases. Yet, this approach requires longer scanning time, increased radiation exposure, and, especially, difficult patient positioning that can affect judgment and data processing. According to high-quality research on orbital imaging, computer-assisted surgery, and artificial intelligent diagnostic development, the correction of a coordinate system is a necessary procedure. Nevertheless, existing manual calibration methods are challenging to reproduce and there is no objective evaluation system for errors. Purpose To establish a method for automatic calibration of orbital CT images and implementation of quantitative error evaluation. Material and Methods A standard three-dimensional (3D) orbit model was manually adjusted, and optimized orbital models were reconstructed based on the initial registration of the skull-bound directed bounding box and the registration of the mutual information method. The calibration error was calculated based on the signed distance field. Seventeen cases of orbital CT were quantitatively evaluated. Results A new method for automatic calibration and quantitative error evaluation for orbital CT was established. The calibrated model error with +/- 2 mm accounted for 81.61% +/- 6.91% of the total models, and the error of +/- 1 mm accounted for 53.49% +/- 7.07% of the total models. Conclusion This convenient tool for orbital CT automatic calibration may promote the related quantitative research based on orbital CT. The automated operation and small error are beneficial to the popularization and application of the tool, and the quantitative evaluation facilitates other coordinate systems.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [1] A unified smoke control method based on signed distance field
    Yang, Ben
    Liu, Youquan
    You, Lihua
    Jin, Xiaogang
    COMPUTERS & GRAPHICS-UK, 2013, 37 (07): : 775 - 786
  • [2] An Evaluation of Survey by Fuzzy Linguistics Based on the Signed Distance Method
    Lin, Lily
    Lee, Huey-Ming
    2009 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS, VOLS 1-3, 2009, : 1457 - +
  • [3] An automatic clustering method based on distance evaluation function
    Zhou Hong-bo
    Gao Jun-tao
    2014 IEEE WORKSHOP ON ELECTRONICS, COMPUTER AND APPLICATIONS, 2014, : 641 - 644
  • [4] A distance-field based automatic neuron tracing method
    Yang, Jinzhu
    Gonzalez-Bellido, Paloma T.
    Peng, Hanchuan
    BMC BIOINFORMATICS, 2013, 14
  • [5] A distance-field based automatic neuron tracing method
    Jinzhu Yang
    Paloma T Gonzalez-Bellido
    Hanchuan Peng
    BMC Bioinformatics, 14
  • [6] Quantitative evaluation of emission computed tomography images based on fuzzy segmentation
    Schmitt, T
    Gebauer, HD
    Freyer, R
    Oehme, L
    Andreeff, M
    Franke, WG
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XIX, 1996, 2847 : 438 - 444
  • [7] sdfibm: a signed distance field based discrete forcing immersed boundary method in OpenFOAM
    Zhang, Chenguang
    COMPUTER PHYSICS COMMUNICATIONS, 2020, 255
  • [8] Automatic registration of pelvic computed tomography data and magnetic resonance scans including a full circle method for quantitative accuracy evaluation
    Van Herk, Marcel
    De Munck, Jan C.
    Lebesque, Joos V.
    Muller, Saar
    Rasch, Coen
    Touw, Adriaan
    Medical Physics, 1998, 25 (10): : 2064 - 2067
  • [9] Automatic registration of pelvic computed tomography data and magnetic resonance scans including a dull circle method for quantitative accuracy evaluation
    van Herk, M
    de Munck, JC
    Lebesque, JV
    Muller, S
    Rasch, C
    Touw, A
    MEDICAL PHYSICS, 1998, 25 (10) : 2054 - 2067
  • [10] L-distance ratio: a new distance ratio-based evaluation method for the diagnosis of cirrhosis using enhanced computed tomography
    Ye, Huifen
    Wang, Qiushi
    Huang, Haitao
    Zhao, Ke
    Li, Pinxiong
    Liu, Zaiyi
    Wang, Guangyi
    Liang, Changhong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1499 - +