High count-rate study of two TES x-ray microcalorimeters with different transition temperatures

被引:1
|
作者
Lee, Sang-Jun [1 ,7 ]
Adams, Joseph S. [1 ,2 ,3 ]
Bandler, Simon R. [1 ]
Betancourt-Martinez, Gabriele L. [1 ,4 ]
Chervenak, James A. [1 ]
Eckart, Megan E. [1 ]
Finkbeiner, Fred M. [1 ,5 ]
Kelley, Richard L. [1 ]
Kilbourne, Caroline A. [1 ]
Porter, Frederick S. [1 ]
Sadleir, John E. [1 ]
Smith, Stephen J. [1 ,2 ,3 ]
Wassell, Edward J. [1 ,6 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[2] CRESST, Baltimore, MD 21250 USA
[3] Univ Maryland Baltimore Cty, Baltimore, MD 21250 USA
[4] Univ Maryland, College Pk, MD 20742 USA
[5] Wyle Informat Syst, Mclean, VA 22102 USA
[6] SGT Inc, Seabrook, MD 20706 USA
[7] Stanford Univ, Stanford, CA 94305 USA
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2017年 / 30卷 / 10期
关键词
superconducting transition-edge sensor; x-ray spectroscopy; high count rate; high energy resolution; EDGE SENSORS; SPECTROSCOPY; RESOLUTION;
D O I
10.1088/1361-6668/aa83d2
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures (T-c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T(c)s had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.3 eV at 6 keV from lower and higher T-c devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the so-called event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96% throughput for 6 keV x-rays of 1025. Hz per pixel with the higher T-c (faster) device, and 5.8. eV FWHM with 97% throughput with the lower T-c (slower) device at 722 Hz.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Transition-edge microcalorimeters for X-ray space applications
    Luukanen, A
    Sipilä, H
    Kinnunen, K
    Nuottajärvi, A
    Pekola, J
    PHYSICA B, 2000, 284 (284): : 2133 - 2134
  • [42] A Study of X-Ray Response of the TES X-Ray Microcalorimeter for STEM
    Muramatsu, Haruka
    Hayashi, Tasuku
    Maehisa, Keisei
    Nakashima, Yuki
    Mitsuda, Kazuhisa
    Yamasaki, Noriko Y.
    Hara, Toru
    Maehata, Keisuke
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [43] High-resolution X-ray spectroscopy of astrophysical plasmas with X-ray microcalorimeters
    Ezoe Y.
    Ohashi T.
    Mitsuda K.
    Reviews of Modern Plasma Physics, 5 (1)
  • [44] Performance of TES X-Ray Microcalorimeters Designed for 14.4-keV Solar Axion Search
    Yagi, Y.
    Konno, R.
    Hayashi, T.
    Tanaka, K.
    Yamasaki, N. Y.
    Mitsuda, K.
    Sato, R.
    Saito, M.
    Homma, T.
    Nishida, Y.
    Mori, S.
    Iyomoto, N.
    Hara, T.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2023, 211 (5-6) : 255 - 264
  • [45] Fabrication of transition edge sensor X-ray microcalorimeters for constellation-X
    Chervenak, JA
    Finkbeiner, FM
    Stevenson, TR
    Talley, DJ
    Brekosky, RP
    Bandler, SR
    Figueroa-Feliciano, E
    Lindeman, MA
    Kelley, RL
    Saab, T
    Stahle, CK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 460 - 462
  • [46] Optimizing Transition-Edge Sensor Design for High Count-Rate Applications
    Smith, Stephen J.
    Adams, Joe S.
    Bandler, Simon R.
    Brekosky, Regis P.
    Brown, Ari-D.
    Chervenak, James A.
    Eckart, Megan E.
    Finkbeiner, Fred M.
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, F. Scott
    Sadleir, John E.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 23 - 26
  • [47] Large Area Transition Edge Sensor X-ray Microcalorimeters for Diffuse X-ray Background Studies
    K. M. Morgan
    S. E. Busch
    M. E. Eckart
    C. A. Kilbourne
    D. McCammon
    Journal of Low Temperature Physics, 2014, 176 : 331 - 336
  • [48] Large Area Transition Edge Sensor X-ray Microcalorimeters for Diffuse X-ray Background Studies
    Morgan, K. M.
    Busch, S. E.
    Eckart, M. E.
    Kilbourne, C. A.
    McCammon, D.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) : 331 - 336
  • [49] Performance of TES X-ray Microcalorimeters with AC Bias Read-Out at MHz Frequencies
    H. Akamatsu
    L. Gottardi
    J. Adams
    S. Bandler
    M. Bruijn
    J. Chervenak
    M. Eckart
    F. Finkbeiner
    R. den Hartog
    H. Hoevers
    R. Kelley
    C. Kilbourne
    J. van der Kuur
    A. J. van den Linden
    F. Porter
    J. Sadleir
    S. Smith
    M. Kiviranta
    Journal of Low Temperature Physics, 2014, 176 : 591 - 596
  • [50] Performance of TES X-Ray Microcalorimeters Designed for 14.4-keV Solar Axion Search
    Y. Yagi
    R. Konno
    T. Hayashi
    K. Tanaka
    N. Y. Yamasaki
    K. Mitsuda
    R. Sato
    M. Saito
    T. Homma
    Y. Nishida
    S. Mori
    N. Iyomoto
    T. Hara
    Journal of Low Temperature Physics, 2023, 211 : 255 - 264