Ultrasensitive Photoelectrochemical Immunoassay for Matrix Metalloproteinase-2 Detection Based on CdS:Mn/CdTe Cosensitized TiO2 Nanotubes and Signal Amplification of SiO2@Ab2 Conjugates

被引:145
|
作者
Fan, Gao-Chao [1 ]
Han, Li [1 ]
Zhu, Hua [1 ]
Zhang, Jian-Rong [1 ,2 ]
Zhu, Jun-Jie [1 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210093, Jiangsu, Peoples R China
[2] Nanjing Univ, Sch Chem & Life Sci, Jinling Coll, Nanjing 210089, Jiangsu, Peoples R China
关键词
CDS QUANTUM DOTS; MESOPOROUS SILICA NANOPARTICLES; DRUG-DELIVERY; PROTEASE ACTIVITY; IMMUNOSENSOR; CARCINOMA; STRATEGY; NANOCRYSTALS; CELL; ANGIOGENESIS;
D O I
10.1021/ac504027d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive photoelectrochemical sandwich immunoassay was developed to detect matrix metalloproteinase-2 (MMP-2, antigen, Ag) based on CdS:Mn/CdTe cosensitized TiO2 nanotubes (TiO2-NTs) and signal amplification of SiO2@Ab(2) conjugates. Specifically, the TiO2-NTs electrode was first deposited with CdS:Mn by successive ionic layer adsorption and reaction technique and then further coated with CdTe quantum dots (QDs) via the layer-by-layer method, forming TiO2-NTs/CdS:Mn/CdTe cosensitized structure, which was employed as a matrix to immobilize capture MMP-2 antibodies (Ab(1)); whereas, SiO2 nanoparticles were coated with signal MMP-2 antibodies (Ab(2)) to form SiO2@Ab(2) conjugates, which were used as signal amplification elements via the specific antibody-antigen immunoreaction between Ag and Ab(2). The ultrahigh sensitivity of this immunoassay derived from the two major reasons as below. First, the TiO2-NTs/CdS:Mn/CdTe cosensitized structure could adequately absorb the light energy, dramatically promote electron transfer, and effectively inhibit the electron-hole recombination, resulting in significantly enhanced photocurrent intensity of the sensing electrode. However, in the presence of target Ag, the immobilized SiO2@Ab(2) conjugates could evidently increase the steric hindrance of the sensing electrode and effectively depress the electron transfer, leading to obviously decreased photocurrent intensity. Accordingly, the well-designed photoelectrochemical immunoassay exhibited a low detection limit of 3.6 fg/mL and a wide linear range from 10 fg/mL to 500 pg/mL for target Ag detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising platform for the detection of other important biomarkers.
引用
收藏
页码:12398 / 12405
页数:8
相关论文
共 50 条
  • [31] Photoelectrochemical biosensor constructed using TiO2 mesocrystals based multipurpose matrix for trypsin detection
    Dai, Hong
    Chen, Sihong
    Li, Yilin
    Zeng, Baoshan
    Zhang, Shupei
    Hong, Zhengsheng
    Lin, Yanyu
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 687 - 694
  • [32] A novel strategy for improving amperometric biosensor sensitivity using dual-signal synergistic effect for ultrasensitive detection of matrix metalloproteinase-2
    Wang, Huiqiang
    Ma, Zhanfang
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 : 46 - 51
  • [33] Ultrasensitive photoelectrochemical immunosensor based on Cu-doped TiO2 and carbon nitride for detection of carcinoembryonic antigen
    Wang, Yaoguang
    Zhao, Guanhui
    Zhang, Yong
    Du, Bin
    Wei, Qin
    CARBON, 2019, 146 : 276 - 283
  • [34] A photoelectrochemical biosensor based on b-TiO2/CdS:Eu/Ti3C2 heterojunction for the ultrasensitive detection of miRNA-21
    Liu, Shen-Ting
    Chen, Jing-Shuai
    Liu, Xing-Pei
    Mao, Chang-Jie
    Jin, Bao-Kang
    TALANTA, 2023, 253
  • [35] A photoelectrochemical aptasensor for the detection of 17β-estradiol based on In2S3 and CdS co-sensitized cerium doped TiO2
    Li, Yuewen
    Xu, Rui
    Wei, Dong
    Feng, Rui
    Fan, Dawei
    Zhang, Nuo
    Wei, Qin
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (02) : 346 - 353
  • [36] Ultrasensitive photoelectrochemical immunoassay based on CdS@Cu2O co-sensitized porous ZnO nanosheets and promoted by multiwalled carbon nanotubes
    Yang, Hongmei
    Sun, Guoqiang
    Zhang, Lina
    Zhang, Yan
    Song, Xianrang
    Yu, Jinghua
    Ge, Shenguang
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 658 - 666
  • [37] Ultrasensitive photoelectrochemical aptasensor for lead ion detection based on sensitization effect of CdTe QDs on MoS2-CdS:Mn nanocomposites by the formation of G-quadruplex structure
    Shi, Jian-Jun
    Zhu, Jing-Chun
    Zhao, Ming
    Wang, Yan
    Yang, Ping
    He, Jie
    TALANTA, 2018, 183 : 237 - 244
  • [38] Design an efficient photoelectrochemical aptasensor for PCB72 based on CdTe@CdS core@shell quantum dots-decorated TiO2 nanotubes
    Liao, Dongyun
    Liang, Guifang
    Liu, Yuyao
    Yan, Wenjun
    Guo, Yujing
    Liang, Wenting
    Dong, Chuan
    Fan, Lifang
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 441
  • [39] A signal-off sandwich photoelectrochemical immunosensor using TiO2 coupled with CdS as the photoactive matrix and copper (II) ion as inhibitor
    Liu, Yixin
    Li, Rongxia
    Gao, Picheng
    Zhang, Yong
    Ma, Hongmin
    Yang, Jiaojiao
    Du, Bin
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2015, 65 : 97 - 102
  • [40] A photoelectrochemical sensor for hydrogen sulfide in cancer cells based on the covalently and in situ grafting of CdS nanoparticles onto TiO2 nanotubes