Ultrasensitive Photoelectrochemical Immunoassay for Matrix Metalloproteinase-2 Detection Based on CdS:Mn/CdTe Cosensitized TiO2 Nanotubes and Signal Amplification of SiO2@Ab2 Conjugates

被引:145
|
作者
Fan, Gao-Chao [1 ]
Han, Li [1 ]
Zhu, Hua [1 ]
Zhang, Jian-Rong [1 ,2 ]
Zhu, Jun-Jie [1 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210093, Jiangsu, Peoples R China
[2] Nanjing Univ, Sch Chem & Life Sci, Jinling Coll, Nanjing 210089, Jiangsu, Peoples R China
关键词
CDS QUANTUM DOTS; MESOPOROUS SILICA NANOPARTICLES; DRUG-DELIVERY; PROTEASE ACTIVITY; IMMUNOSENSOR; CARCINOMA; STRATEGY; NANOCRYSTALS; CELL; ANGIOGENESIS;
D O I
10.1021/ac504027d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive photoelectrochemical sandwich immunoassay was developed to detect matrix metalloproteinase-2 (MMP-2, antigen, Ag) based on CdS:Mn/CdTe cosensitized TiO2 nanotubes (TiO2-NTs) and signal amplification of SiO2@Ab(2) conjugates. Specifically, the TiO2-NTs electrode was first deposited with CdS:Mn by successive ionic layer adsorption and reaction technique and then further coated with CdTe quantum dots (QDs) via the layer-by-layer method, forming TiO2-NTs/CdS:Mn/CdTe cosensitized structure, which was employed as a matrix to immobilize capture MMP-2 antibodies (Ab(1)); whereas, SiO2 nanoparticles were coated with signal MMP-2 antibodies (Ab(2)) to form SiO2@Ab(2) conjugates, which were used as signal amplification elements via the specific antibody-antigen immunoreaction between Ag and Ab(2). The ultrahigh sensitivity of this immunoassay derived from the two major reasons as below. First, the TiO2-NTs/CdS:Mn/CdTe cosensitized structure could adequately absorb the light energy, dramatically promote electron transfer, and effectively inhibit the electron-hole recombination, resulting in significantly enhanced photocurrent intensity of the sensing electrode. However, in the presence of target Ag, the immobilized SiO2@Ab(2) conjugates could evidently increase the steric hindrance of the sensing electrode and effectively depress the electron transfer, leading to obviously decreased photocurrent intensity. Accordingly, the well-designed photoelectrochemical immunoassay exhibited a low detection limit of 3.6 fg/mL and a wide linear range from 10 fg/mL to 500 pg/mL for target Ag detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising platform for the detection of other important biomarkers.
引用
收藏
页码:12398 / 12405
页数:8
相关论文
共 50 条
  • [21] Highly efficient photoelectrochemical aptasensor based on CdS/CdTe QDs co-sensitized TiO2 nanoparticles designed for thrombin detection
    Xu, Xuejiao
    Lu, Yan
    Liu, Dandan
    Zhang, Lu
    Zheng, Lu
    Nie, Guangming
    MICROCHIMICA ACTA, 2024, 191 (04)
  • [22] An electrochemical peptide cleavage-based biosensor for matrix metalloproteinase-2 detection with exonuclease III-assisted cycling signal amplification
    Wang, Ding
    Yuan, Yali
    Zheng, Yingning
    Chai, Yaqin
    Yuan, Ruo
    CHEMICAL COMMUNICATIONS, 2016, 52 (35) : 5943 - 5945
  • [23] Highly sensitive photoelectrochemical aptasensor based on MoS2 quantum dots/TiO2 nanotubes for detection of atrazine
    Fan, Lifang
    Zhang, Caiyun
    Liang, Guifang
    Yan, Wenjun
    Guo, Yujing
    Bi, Yingpu
    Dong, Chuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 334
  • [24] Ultrasensitive photoelectrochemical immunoassay for CA19-9 detection based on CdSe@ZnS quantum dots sensitized TiO2NWs/Au hybrid structure amplified by quenching effect of Ab2@V2+ conjugates
    Zhu, Hua
    Fan, Gao-Chao
    Abdel-Halim, E. S.
    Zhang, Jian-Rong
    Zhu, Jun-Jie
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 339 - 346
  • [25] ZnCuInSe/Au/TiO2 sandwich nanowires-based photoelectrochemical biosensor for ultrasensitive detection of kanamycin
    Geng, Hongchao
    Chen, Xiaoxu
    Sun, Leilei
    Qiao, Yan
    Song, Jie
    Shi, Sisi
    Cai, Qingyun
    ANALYTICA CHIMICA ACTA, 2021, 1146 : 166 - 173
  • [26] A "signal-off" anodic photoelectrochemical sensor based on ZnIn2S4/TiO2 for detection
    Shen, Mao
    Hu, Xiulan
    TALANTA, 2025, 281
  • [27] Ultrasensitive Immunosensor Based on Electrogenerated Chemiluminescence Quenching of CdS/TiO2 Nanotube Arrays for Detection of Antigen
    Gao, Zhi-Da
    Zhuang, Qian-Lan
    Li, Cheng-Yong
    Song, Yan-Yan
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [28] Label-free photoelectrochemical immunosensor based on CdTe/CdS co-sensitized TiO2 nanotube array structure for octachlorostyrene detection
    Cai, Jin
    Sheng, Pengtao
    Zhou, Liping
    Shi, Lei
    Wang, Niya
    Cai, Qingyun
    BIOSENSORS & BIOELECTRONICS, 2013, 50 : 66 - 71
  • [29] Photoelectrochemical label-free immunoassay of octachlorostyrene based on heterogeneous CdSe/CdS/Pt/TiO2 nanotube array
    Manh Nguyen Van
    Li, Weili
    Sheng, Pengtao
    Huan Pham Van
    Cai, Qingyun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 736 : 69 - 75
  • [30] Photoelectrochemical Biosensor for Detection of Mercury(II) Based on CdS Quantum Dots/TiO2 Composite Material
    Zheng Shan
    Liu Yan
    Chen Piao-piao
    Xing Yi-Chen
    Zhang Wei-Bo
    Shi Ya-Ying
    Huang Chao-Biao