Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma

被引:37
|
作者
Si-Mohamed, Salim [1 ,2 ]
Dupuis, Nicolas [1 ,2 ,3 ]
Tatard-Leitman, Valerie [1 ]
Rotzinger, David [4 ]
Boccalini, Sara [2 ]
Dion, Matthias [1 ,2 ,3 ]
Vlassenbroek, Alain [5 ]
Coulon, Philippe [6 ]
Yagil, Yoad [7 ]
Shapira, Nadav [7 ]
Douek, Philippe [1 ,2 ]
Boussel, Loic [1 ,2 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, INSERM, CNRS,INSA Lyon,UJM St Etienne,CREATIS UMR 5220,U1, F-69621 Lyon, France
[2] CHU Louis Pradel, Radiol Dept, Hosp Civils Lyon, 59 Blvd Pinel, F-69500 Bron, France
[3] Lyon Est, Anat Lab, Rockefeller Fac, Lyon, France
[4] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, Lausanne, Switzerland
[5] CT Clin Sci, Best, Netherlands
[6] Philips, CT Clin Sci, Suresnes, France
[7] Philips, Global Adv Technol CT, Haifa, Israel
关键词
Tomography; x-ray computed; Humans; In vitro; Acute disease; Aorta; COMPUTED-TOMOGRAPHY; ATTENUATION MEASUREMENTS; IMAGES; ANGIOGRAPHY; DISSECTION; PRINCIPLES; ACCURACY; DETECTOR; VALUES;
D O I
10.1007/s00330-019-06322-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess whether virtual non-contrast (VNC) images derived from contrast dual-layer dual-energy computed tomography (DL-DECT) images could replace true non-contrast (TNC) images for aortic intramural hematoma (IMH) diagnosis in acute aortic syndrome (AAS) imaging protocols by performing quantitative as well as qualitative phantom and clinical studies. Materials and methods Patients with confirmed IMH were included retrospectively in two centers. For in vitro imaging, a custom-made phantom of IMH was placed in a semi-anthropomorphic thorax phantom (QRM GmbH) and imaged on a DL-DECT at 120 kVp under various conditions of patient size, radiation exposure, and reconstruction modes. For in vivo imaging, 21 patients (70 +/- 13 years) who underwent AAS imaging protocols at 120 kVp were included. In both studies, contrast-to-noise ratio (CNR) between hematoma and lumen was compared using a paired t test. Diagnostic confidence (1 = non-diagnostic, 4 = exemplary) for VNC and TNC images was rated by two radiologists and compared. Effective radiation doses for each acquisition were calculated. Results In both the phantom and clinical studies, we observed that the CNRs were similar between the VNC and TNC images. Moreover, both methods allowed differentiating the hyper-attenuation within the hematoma from the blood. Finally, we obtained equivalent high diagnostic confidence with both VNC and TNC images (VNC = 3.2 + 0.7, TNC = 3.1 + 0.7; p = 0.3). Finally, by suppressing TNC acquisition and using VNC, the mean effective dose reduction would be 40%. Conclusion DL-DECT offers similar performances with VNC and TNC images for IMH diagnosis without compromise in diagnostic image quality. Key Points Dual-layer dual-energy CT enables virtual non-contrast imaging from a contrast-enhanced acquisition. Virtual non-contrast imaging with dual-layer dual-energy CT reduces the number of acquisitions and radiation exposure in acute aortic syndrome imaging protocol. Dual-layer dual-energy CT has the potential to become a suitable imaging tool for acute aortic syndrome.
引用
收藏
页码:6762 / 6771
页数:10
相关论文
共 50 条
  • [41] Using Virtual Non-Contrast CT from Dual-Energy CT to Eliminate the Need for Pre-Contrast CT for Radiation Therapy Planning of Pancreatic Cancer Patients
    Noid, G.
    Tai, A.
    Schott, D.
    Zhu, J.
    Shah, J.
    Paulson, E.
    Prah, D.
    Li, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E368 - E368
  • [42] Association between true non-contrast and virtual non-contrast vertebral bone CT attenuation values determined using dual-layer spectral detector CT
    Ding, Yuqin
    Richter, Andreas
    Stiller, Wolfram
    Kauczor, Hans-Ulrich
    Weber, Tim Frederik
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 121
  • [43] Virtual non-contrast images calculated from dual-energy CT shoulder arthrography improve the detection of intraarticular loose bodies
    Stern, Christoph
    Graf, Dimitri N.
    Bouaicha, Samy
    Wieser, Karl
    Rosskopf, Andrea B.
    Sutter, Reto
    SKELETAL RADIOLOGY, 2022, 51 (08) : 1639 - 1647
  • [44] Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis
    Katherine McCoombe
    Karen Dobeli
    Steven Meikle
    Stacey Llewellyn
    Peter Kench
    European Radiology, 2022, 32 : 8588 - 8596
  • [45] Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis
    McCoombe, Katherine
    Dobeli, Karen
    Meikle, Steven
    Llewellyn, Stacey
    Kench, Peter
    EUROPEAN RADIOLOGY, 2022, 32 (12) : 8588 - 8596
  • [46] Virtual non-contrast images calculated from dual-energy CT shoulder arthrography improve the detection of intraarticular loose bodies
    Christoph Stern
    Dimitri N. Graf
    Samy Bouaicha
    Karl Wieser
    Andrea B. Rosskopf
    Reto Sutter
    Skeletal Radiology, 2022, 51 : 1639 - 1647
  • [47] Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems
    Montoya, J.
    Ferrero, A.
    Yu, L.
    Leng, S.
    McCollough, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [48] Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study
    Faby, Sebastian
    Kuchenbecker, Stefan
    Sawall, Stefan
    Simons, David
    Schlemmer, Heinz-Peter
    Lell, Michael
    Kachelriess, Marc
    MEDICAL PHYSICS, 2015, 42 (07) : 4349 - 4366
  • [49] Dual-Energy Spectral Computed Tomography: Comparing True and Virtual Non Contrast Enhanced Images
    Siruckova, Katerina
    Marcon, Petr
    Dostal, Marek
    Siruckova, Anna
    Dohnal, Premysl
    MEASUREMENT SCIENCE REVIEW, 2022, 22 (06) : 261 - 268
  • [50] Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values
    Toepker, Michael
    Moritz, Thomas
    Krauss, Bernhard
    Weber, Michael
    Euller, Gordon
    Mang, Thomas
    Wolf, Florian
    Herold, Christian J.
    Ringl, Helmut
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E398 - E405