Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis

被引:10
|
作者
McCoombe, Katherine [1 ,2 ]
Dobeli, Karen [1 ,2 ]
Meikle, Steven [1 ]
Llewellyn, Stacey [3 ]
Kench, Peter [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Camperdown, NSW, Australia
[2] Royal Brisbane & Womens Hosp, Dept Med Imaging, Herston, Qld, Australia
[3] QIMR Berghofer Med Res Inst, Herston, Qld, Australia
关键词
Dual-energy CT; Urogram; Urinary calculi; Sensitivity; DIAGNOSTIC PERFORMANCE; COMPUTED-TOMOGRAPHY; ATTENUATION VALUES; DETECTABILITY; FUROSEMIDE;
D O I
10.1007/s00330-022-08939-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To determine the sensitivity of dual-energy (DE) virtual non-contrast computed tomography (vNCT), generated from the excretory phase of a CT urogram, compared to true non-contrast CT (tNCT) for the detection of urinary calculi. Methods A search of multiple medical literature databases was performed using predetermined search terms. Inclusion and exclusion criteria were applied, and bias risk was assessed by two independent reviewers using the quality assessment of diagnostic accuracy studies (QUADAS) tool. Collated estimates of sensitivity were generated, and sources of heterogeneity were identified and reviewed. Results Thirteen studies (1760 patients; 1740 urinary calculi) were included for sensitivity assessment. Pooled sensitivity for urinary calculi on vNCT was 78.1% (95% CI: 70.2 to 85.0%); however, heterogeneity between studies was very high (I-2 = 92.0%). Sources of heterogeneity between studies were explored through subgroup analysis by categorising studies according to slice thickness (>= 2 mm and < 2 mm), use of oral hydration, and use of intravenous furosemide. Pooled sensitivity for detection of urinary calculi on vNCT for studies that used oral hydration and < 2 mm slice thickness was 92.2% (95% CI: 89.5 to 94.5%). Pooled specificity was not performed as true negatives were not reported in most studies. Potential sources of bias were identified in included studies. Conclusion vNCT demonstrated a moderate pooled sensitivity compared to tNCT for the detection of urinary calculi in split bolus CT urogram protocols. However, subgroup analysis suggests higher sensitivity when employing oral hydration and < 2 mm slice thickness or increment.
引用
收藏
页码:8588 / 8596
页数:9
相关论文
共 50 条
  • [1] Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis
    Katherine McCoombe
    Karen Dobeli
    Steven Meikle
    Stacey Llewellyn
    Peter Kench
    European Radiology, 2022, 32 : 8588 - 8596
  • [2] Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis
    Connolly, Michael J.
    McInnes, Matthew D. F.
    El-Khodary, Mohamed
    McGrath, Trevor A.
    Schieda, Nicola
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4324 - 4335
  • [3] Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis
    Michael J. Connolly
    Matthew D. F. McInnes
    Mohamed El-Khodary
    Trevor A. McGrath
    Nicola Schieda
    European Radiology, 2017, 27 : 4324 - 4335
  • [4] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056
  • [5] Detection of fatty liver using virtual non-contrast dual-energy CT
    Pengcheng Peter Zhang
    Hailey H. Choi
    Michael A. Ohliger
    Abdominal Radiology, 2022, 47 : 2046 - 2056
  • [6] Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions
    Matthias Lazar
    Helmut Ringl
    Pascal Baltzer
    Daniel Toth
    Christian Seitz
    Bernhard Krauss
    Ewald Unger
    Stephan Polanec
    Dietmar Tamandl
    Christian J. Herold
    Michael Toepker
    European Radiology, 2020, 30 : 4295 - 4305
  • [7] Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions
    Lazar, Matthias
    Ringl, Helmut
    Baltzer, Pascal
    Toth, Daniel
    Seitz, Christian
    Krauss, Bernhard
    Unger, Ewald
    Polanec, Stephan
    Tamandl, Dietmar
    Herold, Christian J.
    Toepker, Michael
    EUROPEAN RADIOLOGY, 2020, 30 (08) : 4295 - 4305
  • [8] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694
  • [9] Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study
    Herpe, Guillaume
    Platon, Alexandra
    Poletti, Pierre-Alexandre
    Lovblad, Karl O.
    Machi, Paolo
    Becker, Minerva
    Muster, Michel
    Perneger, Thomas
    Guillevin, Remy
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [10] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    Abdominal Radiology, 2023, 48 : 2596 - 2603