Error analysis of a natural breathing calibration method for respiratory inductive plethysmography

被引:9
|
作者
Strömberg, NOT [1 ]
机构
[1] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
关键词
non-invasive; respiratory monitoring; respiratory inductive plethysmography; calibration;
D O I
10.1007/BF02345285
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Respiratory volumes are measured non-invasively by recording rib cage and abdominal motions using respiratory inductive plethysmography (RIP). Qualitative diagnostic calibration (ODC) of RIP is based on the natural variability in the relative rib-cage-to-abdomen contribution during tidal breathing. ODC does not require subject cooperation but it has previously been shown that accuracy may deteriorate when breathing pattern changes. The aim of this study was to investigate the causes and situations where ODC accuracy deteriorates. The ODC method was compared to PRA (calibration during voluntarily preferential rib cage or abdomen breathing) in ten adults. A reference RIP calibration was obtained from all validation data (REF). The PRA method had better accuracy than the ODC method (p < 0.01). The volumetric error ranged between 10% and 136% with ODC and between 5% and 33% with PRA, The PRA calibration factors were within 6% of those from REF, while the ODC rib-cage factor was underestimated by 15% and the abdominal factor was overestimated by 38%. Small natural variability in the relative rib-cage-to-abdomen contribution was related to poor accuracy. Each compartment's variability depended on its magnitude, which is a violation of the ODC assumptions.
引用
收藏
页码:310 / 314
页数:5
相关论文
共 50 条
  • [41] Respiratory function parameters in infants using inductive plethysmography
    Selbie, R.D.
    Fletcher, M.
    Arestis, N.
    White, R.
    Duncan, A.
    Helms, P.
    Duffty, P.
    Medical Engineering and Physics, 1997, 19 (06): : 501 - 511
  • [42] CALIBRATION OF RESPIRATORY INDUCTION PLETHYSMOGRAPHY (RESPITRACE) IN INFANTS
    DOLFIN, T
    DUFFTY, P
    WILKES, DL
    BRYAN, MH
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 126 (03): : 577 - 579
  • [43] Respiratory inductive plethysmography: a comparative study between isovolume maneuver calibration and qualitative diagnostic calibration in healthy volunteers assessed in different positions
    Claudino Barbosa, Renata Cleia
    Fernandes de Carvalho, Celso Ricardo
    Moriya, Henrique Takachi
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2012, 38 (02) : 194 - 201
  • [44] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY FOR MEASUREMENT OF PARAMETERS OF RESPIRATORY-FUNCTION DURING SLEEP IN LAMBS USING THE SINGLE POSITION GRAPHIC TECHNIQUE
    WARREN, RH
    ALDERSON, SH
    FEWELL, JE
    CLINICAL RESEARCH, 1986, 34 (01): : A263 - A263
  • [45] Respiratory inductive plethysmography as a method for measuring ventilatory parameters in conscious, non-restrained dogs
    Murphy, Dennis J.
    Renninger, Jonathan P.
    Schramek, Daniel
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2010, 62 (01) : 47 - 53
  • [46] Accuracy of respiratory inductive plethysmography in estimating lung volume changes
    Markhorst, DG
    van Genderingen, HR
    CRITICAL CARE MEDICINE, 2004, 32 (05) : 1241 - 1242
  • [47] WORKPLACE MEASUREMENT OF RESPIRATOR EFFECTS USING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    HODOUS, TK
    HANKINSON, JL
    STARK, GP
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1989, 50 (07): : 372 - 378
  • [48] COMPARISON OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY AND THORACIC IMPEDANCE FOR APNEA MONITORING
    BROUILLETTE, RT
    MORROW, AS
    WEESEMAYER, DE
    HUNT, CE
    JOURNAL OF PEDIATRICS, 1987, 111 (03): : 377 - 383
  • [49] Respiratory inductive plethysmography is stable during high frequency ventilation
    Brazelton, TB
    Watson, KF
    Thompson, JE
    Arnold, JH
    PEDIATRIC RESEARCH, 1999, 45 (04) : 38A - 38A
  • [50] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN PATIENTS WITH PULMONARY-DISEASE
    TOBIN, MJ
    JENOURI, G
    LIND, B
    WATSON, H
    SCHNEIDER, A
    SACKNER, MA
    CHEST, 1983, 83 (04) : 615 - 620