Error analysis of a natural breathing calibration method for respiratory inductive plethysmography

被引:9
|
作者
Strömberg, NOT [1 ]
机构
[1] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
关键词
non-invasive; respiratory monitoring; respiratory inductive plethysmography; calibration;
D O I
10.1007/BF02345285
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Respiratory volumes are measured non-invasively by recording rib cage and abdominal motions using respiratory inductive plethysmography (RIP). Qualitative diagnostic calibration (ODC) of RIP is based on the natural variability in the relative rib-cage-to-abdomen contribution during tidal breathing. ODC does not require subject cooperation but it has previously been shown that accuracy may deteriorate when breathing pattern changes. The aim of this study was to investigate the causes and situations where ODC accuracy deteriorates. The ODC method was compared to PRA (calibration during voluntarily preferential rib cage or abdomen breathing) in ten adults. A reference RIP calibration was obtained from all validation data (REF). The PRA method had better accuracy than the ODC method (p < 0.01). The volumetric error ranged between 10% and 136% with ODC and between 5% and 33% with PRA, The PRA calibration factors were within 6% of those from REF, while the ODC rib-cage factor was underestimated by 15% and the abdominal factor was overestimated by 38%. Small natural variability in the relative rib-cage-to-abdomen contribution was related to poor accuracy. Each compartment's variability depended on its magnitude, which is a violation of the ODC assumptions.
引用
收藏
页码:310 / 314
页数:5
相关论文
共 50 条
  • [21] Evaluation of respiratory inductive plethysmography - Accuracy for analysis of respiratory waveforms
    Carry, PY
    Baconnier, P
    Eberhard, A
    Cotte, P
    Benchetrit, G
    CHEST, 1997, 111 (04) : 910 - 915
  • [22] Automated respiratory inductive plethysmography to evaluate breathing in infants at risk for postoperative apnea
    Brown, Karen A.
    Aoude, Ahmed A.
    Galiana, Henrietta L.
    Kearney, Robert E.
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2008, 55 (11): : 739 - 747
  • [23] RESPIRATORY MONITORING BY INDUCTIVE PLETHYSMOGRAPHY
    HANNING, CD
    SMITH, HC
    LEDINGHAM, IM
    INTENSIVE CARE MEDICINE, 1977, 3 (03) : 126 - 126
  • [24] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN LAMBS RECEIVING INTERMITTENT MANDATORY MECHANICAL VENTILATION
    WARREN, RH
    ALDERSON, SH
    CRITICAL CARE MEDICINE, 1988, 16 (02) : 161 - 164
  • [25] INDUCTIVE PLETHYSMOGRAPHY - NEW RESPIRATORY TRANSDUCER
    MILLEDGE, JS
    STOTT, FD
    JOURNAL OF PHYSIOLOGY-LONDON, 1977, 267 (01): : P4 - P5
  • [26] Scoring Tools for the Analysis of Infant Respiratory Inductive Plethysmography Signals
    Robles-Rubio, Carlos Alejandro
    Bertolizio, Gianluca
    Brown, Karen A.
    Kearney, Robert E.
    PLOS ONE, 2015, 10 (07):
  • [27] RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY MEASUREMENT OF BREATHING PATTERNS CREATED BY CONTROLLED MECHANICAL VENTILATION IN SEDATED PIGLETS
    WARREN, RH
    ALDERSON, SH
    CLINICAL RESEARCH, 1988, 36 (01): : A77 - A77
  • [28] NEW TRENDS IN THE USE OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    DALLAVASANTUCCI, J
    BIOLOGICAL PSYCHOLOGY, 1993, 35 (03) : 269 - 269
  • [29] Respiratory Monitoring by Inductive Plethysmography in Unrestrained Subjects Using Position Sensor-Adjusted Calibration
    Bruellmann, Gregor
    Fritsch, Karsten
    Thurnheer, Robert
    Bloch, Konrad E.
    RESPIRATION, 2010, 79 (02) : 112 - 120
  • [30] COMPARISON OF PIEZOELECTRODE BELTS TO RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    Foreman, E. B.
    Underwood, W. W.
    Vaughn, B. V.
    SLEEP, 2009, 32 : A373 - A373