Study of total positioning accuracy of a newly developed image-guided radiotherapy system

被引:0
|
作者
Kaneko, S.
Takayama, K.
Nagano, K.
Narita, Y.
Kokubo, M.
Takahashi, K.
Mizowaki, T.
Hiraoka, M.
机构
[1] Mitsubishi Heavy Ind Co Ltd, Hiroshima, Japan
[2] Inst Biomed Res & Innovat, Kobe, Hyogo, Japan
[3] Kyoto Univ, Kyoto, Japan
关键词
D O I
10.1118/1.2761289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate system accuracy of our newly developed image‐guided radiotherapy (IGRT) system. Method and Materials: The system has the following structural characteristics; (1) C‐band compact linear accelerator (LINAC), (2) O‐ring shaped gantry, (3) Gimbals mechanism at X‐ray head, and (4) Imaging subsystem. The whole X‐ray head with the LINAC and a MLC is equipped on gimbals mechanism to correct beam direction to isocenter. The imaging subsystem mounted on the O‐ring gantry consists of two sets of a kV X‐ray tube with an image detector, and can obtain either X‐ray images or cone‐beam CT (CBCT) images. By using Electronic Portal Imaging Device, the IGRT system also provides an automatic daily QA tool for total positioning accuracy, which means beam accuracy towards isocenter combined with image‐guiding accuracy. The daily QA requires only 3 minutes. Firstly in this study, to evaluate the image‐guiding accuracy, a spherical metal ball with a diameter of 10 mm was set at given positions within 20 mm from isocenter. X‐ray images or CBCT images were obtained to measure the ball position, and the difference between true and measured position was calculated. Secondly, Mechanical accuracy of beam direction to isocenter was measured in various gantry angles with CCD camera attached to MLC frame. Finally, the combined accuracy was verified by using the daily QA tool. Results: The difference between true and measured position was 0.34 mm in SD and 0.9 mm at the maximum for X‐ray image, then 0.17mm in SD and 0.4 mm at the maximum for CBCT, respectively. Mechanical beam accuracy was within 0.1mm. The combined accuracy was better than 0.5 mm. Conclusion: The IGRT system has suitable accuracy for image‐guided stereotactic irradiation. Conflict of Interest: Research sponsored by New Energy and Industrial Technology Development Organization, Japan. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2533 / 2533
页数:1
相关论文
共 50 条
  • [31] From image-guided radiotherapy to dose-guided radiotherapy
    Cazoulat, G.
    Lesaunier, M.
    Simon, A.
    Haigron, P.
    Acosta, O.
    Louvel, G.
    Lafond, C.
    Chajon, E.
    Leseur, J.
    de Crevoisier, R.
    CANCER RADIOTHERAPIE, 2011, 15 (08): : 691 - 698
  • [32] The future of image-guided radiotherapy will be MR guided
    Pollard, Julianne M.
    Wen, Zhifei
    Sadagopan, Ramaswamy
    Wang, Jihong
    Ibbott, Geoffrey S.
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1073):
  • [33] Accuracy of positioning and irradiation targeting for multiple targets in intracranial image-guided radiation therapy: a phantom study
    Tominaga, Hirofumi
    Araki, Fujio
    Shimohigashi, Yoshinobu
    Ishihara, Terunobu
    Kawasaki, Keiichi
    Kanetake, Nagisa
    Sakata, Junichi
    Iwashita, Yuki
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24): : 7753 - 7766
  • [34] Application of a newly developed high-accuracy image guided radiation therapy system to stereotactic radiosurgery
    Takayama, K.
    Nagano, K.
    Mizowaki, T.
    Takahashi, K.
    Kaneko, S.
    Nakayama, H.
    Kawada, N.
    Narita, Y.
    Kokubo, M.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S627 - S628
  • [35] Treatment time of image-guided radiotherapy with a Halcyon 2.0 system
    Hermida-Lopez, Marcelino
    Garcia-Relancio, David
    Comino-Muriano, Marina
    Perez-Esteve, Brenda
    Castillo-Elias, Esther
    Carrera-Garcia, Yolanda
    Giralt, Jordi
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (01) : 117 - 122
  • [36] Accuracy and variability of image-guided radiotherapy during hypofractionated treatment for prostate cancer
    Braithwaite, L.
    Wu, J.
    Karachewsky, R.
    Skarsgard, D.
    El-Gayed, A.
    Pearcey, R.
    Joseph, K.
    Newcomb, C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S55 - S55
  • [37] Physics Support of Image-guided Radiotherapy
    Eaton, D. J.
    CLINICAL ONCOLOGY, 2013, 25 (03) : E31 - E31
  • [38] Small animal image-guided radiotherapy
    Verhaegen, Frank
    Vaz, Pedro
    Prise, Kevin M.
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):
  • [39] Intercomparison of image-guided and non invasive frame-guided stereotactic positioning for head and neck radiotherapy
    Monshouwer, R.
    Van der Maazen, R.
    Louwe, R.
    Visser, A. G.
    Huizenga, H.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S102 - S103
  • [40] Image-guided radiotherapy for gynaecological cancer
    Lucia, F.
    Schick, U.
    Pradier, O.
    Espenel, S.
    de Crevoisier, R.
    Chargari, C.
    CANCER RADIOTHERAPIE, 2018, 22 (6-7): : 608 - 616