Study of total positioning accuracy of a newly developed image-guided radiotherapy system

被引:0
|
作者
Kaneko, S.
Takayama, K.
Nagano, K.
Narita, Y.
Kokubo, M.
Takahashi, K.
Mizowaki, T.
Hiraoka, M.
机构
[1] Mitsubishi Heavy Ind Co Ltd, Hiroshima, Japan
[2] Inst Biomed Res & Innovat, Kobe, Hyogo, Japan
[3] Kyoto Univ, Kyoto, Japan
关键词
D O I
10.1118/1.2761289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate system accuracy of our newly developed image‐guided radiotherapy (IGRT) system. Method and Materials: The system has the following structural characteristics; (1) C‐band compact linear accelerator (LINAC), (2) O‐ring shaped gantry, (3) Gimbals mechanism at X‐ray head, and (4) Imaging subsystem. The whole X‐ray head with the LINAC and a MLC is equipped on gimbals mechanism to correct beam direction to isocenter. The imaging subsystem mounted on the O‐ring gantry consists of two sets of a kV X‐ray tube with an image detector, and can obtain either X‐ray images or cone‐beam CT (CBCT) images. By using Electronic Portal Imaging Device, the IGRT system also provides an automatic daily QA tool for total positioning accuracy, which means beam accuracy towards isocenter combined with image‐guiding accuracy. The daily QA requires only 3 minutes. Firstly in this study, to evaluate the image‐guiding accuracy, a spherical metal ball with a diameter of 10 mm was set at given positions within 20 mm from isocenter. X‐ray images or CBCT images were obtained to measure the ball position, and the difference between true and measured position was calculated. Secondly, Mechanical accuracy of beam direction to isocenter was measured in various gantry angles with CCD camera attached to MLC frame. Finally, the combined accuracy was verified by using the daily QA tool. Results: The difference between true and measured position was 0.34 mm in SD and 0.9 mm at the maximum for X‐ray image, then 0.17mm in SD and 0.4 mm at the maximum for CBCT, respectively. Mechanical beam accuracy was within 0.1mm. The combined accuracy was better than 0.5 mm. Conclusion: The IGRT system has suitable accuracy for image‐guided stereotactic irradiation. Conflict of Interest: Research sponsored by New Energy and Industrial Technology Development Organization, Japan. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2533 / 2533
页数:1
相关论文
共 50 条
  • [21] A review of image-guided radiotherapy
    Chen G.T.Y.
    Sharp G.C.
    Mori S.
    Radiological Physics and Technology, 2009, 2 (1) : 1 - 12
  • [22] Implementation of Image-guided Radiotherapy
    Franks, K. N.
    McNair, H. A.
    CLINICAL ONCOLOGY, 2012, 24 (09) : 625 - 626
  • [23] Image-guided Gated Radiotherapy
    Heaton, A.
    Shakeshaft, J.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 268 - 268
  • [24] Innovations in image-guided radiotherapy
    Dirk Verellen
    Mark De Ridder
    Nadine Linthout
    Koen Tournel
    Guy Soete
    Guy Storme
    Nature Reviews Cancer, 2007, 7 : 949 - 960
  • [25] RETRACTED: Research on Improving Radiotherapy Accuracy Based on Image-Guided Radiotherapy (Retracted Article)
    Huang, Shunping
    Xiao, Yang
    Li, Heng
    Li, Daochang
    CONTRAST MEDIA & MOLECULAR IMAGING, 2022, 2022
  • [26] Accuracy of image-guided implantology
    Brief, J
    Edinger, D
    Hassfeld, S
    Eggers, G
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 495 - 501
  • [27] Regular assessment of isocentre and positioning accuracy in image guided stereotactic radiotherapy
    Heinz, C.
    Neppl, S.
    Haimerl, W.
    Belka, C.
    Reiner, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S912 - S912
  • [28] Precision of image-guided spinal stereotactic ablative radiotherapy and impact of positioning variables
    Billiet, Charlotte
    Vingerhoed, Wim
    Van Laere, Steven
    Joye, Ines
    Mercier, Carole
    Dirix, Piet
    Nevens, Daan
    Vermeulen, Peter
    Meijnders, Paul
    Verellen, Dirk
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 73 - 76
  • [29] Development of an image-guided robotic system for surgical positioning and drilling
    Tseng, Ching-Shiow
    Huang, Chiao-Chi
    Chen, Chen-San
    ROBOTICA, 2007, 25 (03) : 375 - 383
  • [30] Feasibility Study of Backscatter Imaging for Image-Guided Radiotherapy
    Sensakovic, W. F.
    Wang, S.
    Yao, R.
    Turian, J.
    Chu, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3667 - 3667