EFFECT OF TIP CLEARANCE ON SUCTION PERFORMANCE AT DIFFERENT FLOW RATES IN A MIXED FLOW PUMP

被引:0
|
作者
Jung, Yo Han [1 ]
Min, Young Uk [1 ]
Kim, Jin Young [1 ]
机构
[1] Hyundai Heavy Ind Co Ltd, Ulsan, South Korea
关键词
CENTRIFUGAL PUMP; INDUCER; CAVITATION; IMPELLER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Numerical simulation of internal flow field in axial-flow pump with different blade tip clearance sizes
    Shi, Weidong
    Zhang, Hua
    Chen, Bin
    Zhang, Desheng
    Zhang, Lei
    Paiguan Jixie Gongcheng Xuebao/Journal of Drainage and Irrigation Machinery Engineering, 2010, 28 (05): : 374 - 377
  • [42] Effect of tip clearance height on tip clearance flow in turbine rotors
    Niu, Mao-Sheng
    Zang, Shu-Sheng
    Huang, Ming-Hai
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2008, 29 (06): : 935 - 939
  • [43] Study on the performance deterioration of mixed flow impeller due to change in tip clearance
    D. Ramesh Rajakumar
    S. Ramamurthy
    M. Govardhan
    Journal of Thermal Science, 2013, 22 : 532 - 538
  • [44] Experimental investigations on effects of tip clearance in mixed-flow compressor performance
    Rajakumar, D. Ramesh
    Ramamurthy, S.
    Govardhan, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2015, 229 (05) : 933 - 946
  • [45] Study on the Performance Deterioration of Mixed Flow Impeller due to Change in Tip Clearance
    Ramesh Rajakumar.D
    Ramamurthy.S
    Govardhan.M
    Journal of Thermal Science, 2013, 22 (06) : 532 - 538
  • [46] Effects of Tip Clearance and Impeller Eccentricity on the Aerodynamic Performance of Mixed Flow Fan
    Liu, Shulian
    Guo, Yizhe
    Zhang, Yuchi
    Gu, Cunkai
    Yang, Likang
    SYMMETRY-BASEL, 2023, 15 (01):
  • [47] Study on the Performance Deterioration of Mixed Flow Impeller due to Change in Tip Clearance
    Rajakumar, Ramesh D.
    Ramamurthy, S.
    Govardhan, M.
    JOURNAL OF THERMAL SCIENCE, 2013, 22 (06) : 532 - 538
  • [48] NUMERICAL INVESTIGATION OF INFLUENCE OF TIP CLEARANCE IN MIXED-FLOW COMPRESSOR PERFORMANCE
    Zhang, Guo-jie
    Li, Yi-min
    Zhou, Zhong-ning
    TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2015, 9 (04): : 388 - 394
  • [49] Particle image velocimetry measurement of flow fields in a mixed-flow pump with non-uniform tip clearance
    Li, Wei
    Ji, Leilei
    Shi, Weidong
    Li, Enda
    Yang, Zhenyu
    JOURNAL OF VISUALIZATION, 2021, 24 (01) : 29 - 45
  • [50] Particle image velocimetry measurement of flow fields in a mixed-flow pump with non-uniform tip clearance
    Wei Li
    Leilei Ji
    Weidong Shi
    Enda Li
    Zhenyu Yang
    Journal of Visualization, 2021, 24 : 29 - 45