EFFECT OF TIP CLEARANCE ON SUCTION PERFORMANCE AT DIFFERENT FLOW RATES IN A MIXED FLOW PUMP

被引:0
|
作者
Jung, Yo Han [1 ]
Min, Young Uk [1 ]
Kim, Jin Young [1 ]
机构
[1] Hyundai Heavy Ind Co Ltd, Ulsan, South Korea
关键词
CENTRIFUGAL PUMP; INDUCER; CAVITATION; IMPELLER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Theoretical Prediction Model of Tip Leakage Vortex in a Mixed Flow Pump With Tip Clearance
    Liu, Yabin
    Tan, Lei
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (02):
  • [22] Numerical analysis for the effect of tip clearance in a low specific speed mixed-flow pump
    Yu, Zhiyi
    Zhang, Wenwu
    Zhu, Baoshan
    Li, Yongjiang
    ADVANCES IN MECHANICAL ENGINEERING, 2019, 11 (03)
  • [23] Effect of skewed blades on tip-clearance for different flow rates in axial fans
    Jin, Guangyuan
    Ouyang, Hua
    Wu, Yadong
    Du, Zhaohui
    NOISE CONTROL ENGINEERING JOURNAL, 2011, 59 (04) : 320 - 332
  • [24] THE EFFECT OF TIP LEAKAGE FLOW ON PART-LOAD PERFORMANCE OF A MIXED-FLOW PUMP IMPELLER
    GOTO, A
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1992, 114 (02): : 383 - 391
  • [25] Influence of tip clearance on the performance of a screw axial-flow pump
    Lin, Peng
    Liu, Meiqing
    Zhao, Wensheng
    Liu, Zhiyong
    Wu, Yuanwei
    Xue, Fei
    Zhang, Yipeng
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (06):
  • [26] Effects of inducer tip clearance on the performance and flow characteristics of a pump in a turbopump
    Kim, Changhyun
    Kim, Semi
    Choi, Chang-Ho
    Baek, Jehyun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2017, 231 (05) : 398 - 414
  • [27] Investigation of cavitation and flow characteristics of tip clearance of bidirectional axial flow pump with different clearances
    Wang, Lin
    Tang, Fangping
    Liu, Haiyu
    Zhang, Xiaowen
    Sun, Zhuangzhuang
    Wang, Fei
    OCEAN ENGINEERING, 2023, 288
  • [28] Study on the Cavitation Performance in the Impeller Region of a Mixed-Flow Pump Under Different Flow Rates
    Yang, Xu
    Zhu, Jianzhong
    Zhang, Yi
    Chen, Buqing
    Tang, Yiping
    Jiang, Rui
    Kan, Kan
    Ye, Changliang
    Zheng, Yuan
    WATER, 2024, 16 (22)
  • [29] Tip clearance and tip vortex cavitation in an axial flow pump
    Laborde, R
    Chantrel, P
    Mory, M
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 680 - 685
  • [30] Spatial-Temporal Evolution of Tip Leakage Vortex in a Mixed-Flow Pump With Tip Clearance
    Liu, Yabin
    Tan, Lei
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (08):