Dosimetric comparison of RapidPlan and manually optimized plans in volumetric modulated arc therapy for prostate cancer

被引:80
|
作者
Kubo, Kazuki [1 ,2 ]
Monzen, Hajime [1 ]
Ishii, Kentaro [2 ]
Tamura, Mikoto [1 ]
Kawamorita, Ryu [2 ]
Sumida, Iori [3 ]
Mizuno, Hirokazu [3 ]
Nishimura, Yasumasa [4 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Ohno Higashi, Osaka 5898511, Japan
[2] Tane Gen Hosp, Dept Radiat Oncol, Nishi Ku, 1-12-21 Kujo Minami, Osaka 5500025, Japan
[3] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[4] Kindai Univ, Fac Med, Dept Radiat Oncol, 377-2 Ohno Higashi, Osaka 5898511, Japan
基金
日本学术振兴会;
关键词
Knowledge-based planning; RapidPlan; VMAT; Prostate cancer; QUALITY-ASSURANCE; IMRT; VALIDATION; VMAT; RADIOTHERAPY; IMPACT; MODEL;
D O I
10.1016/j.ejmp.2017.06.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer. Methods: We used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D-95%, and D-2% to planning target volume (PTV), mean dose, V-50Gy, V-70Gy, V-75Gy, and V-78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity. Results: RP and CMO values for PTV D-95%, PTV D-2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V-50Gy, and V-70Gy to rectum were superior or comparable to CMO values; RP V-75Gy and V-78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V-78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 +/- 55 MU and CMO: 580 +/- 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 +/- 0.02 and CMO: 0.35 +/- 0.03 (p < 0.05). Conclusions: RP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner's skill and knowledge. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [41] Dosimetric Comparison of Volumetric Arc Therapy and Intensity Modulated Radiotherapy for Glioblastoma Treatment
    Kaptan, I.
    Ugurluer, G.
    Ispir, B.
    Akdeniz, Y.
    Serin, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [42] Dosimetric Comparison of Coplanar Volumetric Modulated Arc Therapy and Non-coplanar Intensity Modulated Radiation Therapy for Pancreatic Cancer
    Badkul, R. K.
    Kile, L.
    Saleh, H.
    Chen, A. M.
    Lominska, C. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E636
  • [43] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu Xia
    Liu Zhikai
    Pang Tingtian
    Dong Tingting
    Qiu Jie
    儿科学研究(英文), 2020, 04 (03) : 186 - 191
  • [44] Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer
    Takagi, Masaru
    Hasegawa, Yasuhiro
    Tateoka, Kunihiko
    Takada, Yu
    Hareyama, Masato
    CANCERS, 2024, 16 (02)
  • [45] Dosimetric comparison between using daily cone beam CT and planning CT in Volumetric Modulated Arc Therapy technique for prostate cancer therapy
    Chanayota, J.
    Suriyapee, S.
    Alisanant, P.
    Sanghangthum, T.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [46] DOSIMETRIC VERIFICATION OF RAPIDARC™ VOLUMETRIC MODULATED ARC THERAPY
    Medin, J.
    Kjaer-Kristoffersen, F.
    Ceberg, S.
    Back, S.
    Gustavsson, H.
    Archambault, Y.
    Bocanek, J.
    Cozzi, L.
    Eberhard, V.
    Gomola, I.
    Wiberg, I.
    Korreman, S.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S47 - S48
  • [47] Dosimetric effects of weight loss or gain during volumetric modulated arc therapy and intensity-modulated radiation therapy for prostate cancer
    Pair, Matthew L.
    Du, Weiliang
    Rojas, Hector D.
    Kanke, James E.
    McGuire, Sean E.
    Lee, Andrew K.
    Kuban, Deborah A.
    Kudchadker, Rajat J.
    MEDICAL DOSIMETRY, 2013, 38 (03) : 251 - 254
  • [48] Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT) with and without Flattening Filter for Stereotactic Body Radiation Therapy (SBRT) in Localised Prostate Cancer
    Cher, S. J. Y.
    Chan, T. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E104 - E104
  • [49] The Dosimetric Effects of Photon Energy on the Quality of Prostate Volumetric Modulated Arc Therapy (VMAT)
    Mattes, M. D.
    Tai, C.
    Ashamalla, H.
    Ikoro, N. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S771 - S772
  • [50] Dosimetric Comparison of Tangential Volumetric Arc Therapy and Half Beam Volumetric Modulated Arc Therapy Planning Technique for Carcinoma of the Breast
    Benny, Alpha
    Rao, Shreekripa
    Chandraguthi, Srinidhi G.
    Dsouza, Rechal Nisha
    Sharan, Krishna
    Iranian Journal of Medical Physics, 2024, 21 (05) : 306 - 313