Dosimetric comparison of RapidPlan and manually optimized plans in volumetric modulated arc therapy for prostate cancer

被引:80
|
作者
Kubo, Kazuki [1 ,2 ]
Monzen, Hajime [1 ]
Ishii, Kentaro [2 ]
Tamura, Mikoto [1 ]
Kawamorita, Ryu [2 ]
Sumida, Iori [3 ]
Mizuno, Hirokazu [3 ]
Nishimura, Yasumasa [4 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Ohno Higashi, Osaka 5898511, Japan
[2] Tane Gen Hosp, Dept Radiat Oncol, Nishi Ku, 1-12-21 Kujo Minami, Osaka 5500025, Japan
[3] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[4] Kindai Univ, Fac Med, Dept Radiat Oncol, 377-2 Ohno Higashi, Osaka 5898511, Japan
基金
日本学术振兴会;
关键词
Knowledge-based planning; RapidPlan; VMAT; Prostate cancer; QUALITY-ASSURANCE; IMRT; VALIDATION; VMAT; RADIOTHERAPY; IMPACT; MODEL;
D O I
10.1016/j.ejmp.2017.06.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer. Methods: We used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D-95%, and D-2% to planning target volume (PTV), mean dose, V-50Gy, V-70Gy, V-75Gy, and V-78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity. Results: RP and CMO values for PTV D-95%, PTV D-2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V-50Gy, and V-70Gy to rectum were superior or comparable to CMO values; RP V-75Gy and V-78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V-78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 +/- 55 MU and CMO: 580 +/- 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 +/- 0.02 and CMO: 0.35 +/- 0.03 (p < 0.05). Conclusions: RP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner's skill and knowledge. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [31] Dosimetric advantage of volumetric modulated arc therapy in the treatment of intraocular cancer
    Zhenxiang Deng
    Lanxiao Shen
    Xiaomin Zheng
    Yongqiang Zhou
    Jinling Yi
    Ce Han
    Congying Xie
    Xiance Jin
    Radiation Oncology, 12
  • [32] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [33] Simultaneous-integrated boost volumetric-modulated arc therapies in prostate cancer: A dosimetric comparison
    Cabrera, P.
    Peinado, J.
    Rubio, M.
    Vincent, D.
    Velazquez, S.
    Herrador, M.
    Ortiz, M. J.
    Praena-Fernandez, J. M.
    Mateos, J. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S137 - S138
  • [34] Dosimetric Comparison of the Newest Version Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy Plans for Angiosarcoma of the Scalp
    Mizuno, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E10 - E10
  • [35] Dosimetric Evaluation at Volumetric Modulated Arc Therapy for Treatment of Prostate Cancer Using Single Or Double Arcs
    Silva, D.
    Salmon, H.
    Pavan, G.
    Nardi, S.
    Anderson, E.
    Fairbanks, L.
    Junior, J.
    Cursino, F.
    Colodette, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 167 - 167
  • [36] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [37] A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT
    Stathakis, Sotirios
    Narayanasamy, Ganesh
    Licon, Anna Laura
    Myers, Pamela
    Li, Ying
    Crownover, Richard
    Papanikolaou, Niko
    JOURNAL OF BUON, 2019, 24 (02): : 838 - 843
  • [38] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [39] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [40] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu, Xia
    Liu, Zhikai
    Pang, Tingtian
    Dong, Tingting
    Qiu, Jie
    PEDIATRIC INVESTIGATION, 2020, 4 (03) : 186 - 191