RESTORING ARTIFACT-FREE MICROSCOPY IMAGE SEQUENCES

被引:0
|
作者
Yin, Zhaozheng [1 ]
Kanade, Takeo [1 ]
机构
[1] Carnegie Mellon Univ, Inst Robot, Pittsburgh, PA 15213 USA
关键词
Microscopy image analysis; image restoration; phase contrast; differential interference contrast;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Phase contrast and differential interference contrast, which are used to capture microscopy images of living cells, contain a few artifacts such as halo and shadow-cast effect. Removing these artifacts from microscopy images facilitates automated microscopy image analysis, such as the cell segmentation that is a critical step in cell tracking systems. We propose a restoration algorithm based on the microscopy imaging model and consider temporal consistency when restoring time-lapse microscopy image sequences. The artifact-free microscopy images are restored by minimizing a regularized quadratic cost function that is adaptable to input image properties. Our method achieves high segmentation accuracy and low computational cost compared to the previous methods.
引用
收藏
页码:909 / 913
页数:5
相关论文
共 50 条
  • [41] Avocodo: Generative Adversarial Network for Artifact-Free Vocoder
    Bak, Taejun
    Lee, Junmo
    Bae, Hanbin
    Yang, Jinhyeok
    Bae, Jae-Sung
    Joo, Young-Sun
    THIRTY-SEVENTH AAAI CONFERENCE ON ARTIFICIAL INTELLIGENCE, VOL 37 NO 11, 2023, : 12562 - 12570
  • [42] ARTIFACT-FREE THIN CLOUD REMOVAL USING GANS
    Toizumi, Takahiro
    Zini, Simone
    Sagi, Kazutoshi
    Kaneko, Eiji
    Tsukada, Masato
    Schettini, Raimondo
    2019 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2019, : 3596 - 3600
  • [43] Development and Evaluation of an MRI Artifact-Free Aneurysm Clip
    Senger, Sebastian
    Fischer, Gerrit
    Muehl-Benninghaus, Ruben
    Backens, Martin
    Reisel, Jan Rene
    Fritz, Tobias
    Brack, Alexander
    Reith, Wolfgang
    Oertel, Joachim
    OPERATIVE NEUROSURGERY, 2024, 26 (06) : 635 - 644
  • [44] ARTIFACT-FREE APPLICATION OF DRUGS INTO THE AVIAN ENDOLYMPHATIC SPACE
    RICHTER, C
    KLINKE, R
    JOURNAL OF NEUROSCIENCE METHODS, 1994, 51 (02) : 171 - 175
  • [45] A POTENTIALLY ARTIFACT-FREE ORAL CONTRAST AGENT FOR GASTROINTESTINAL MRI
    LIEBIG, T
    STOUPIS, C
    ROS, PR
    BALLINGER, JR
    BRIGGS, RW
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (05) : 646 - 649
  • [46] Toward realistic and artifact-free insider-threat data
    Killourhy, Kevin S.
    Maxion, Roy A.
    TWENTY-THIRD ANNUAL COMPUTER SECURITY APPLICATIONS CONFERENCE, PROCEEDINGS, 2007, : 87 - 96
  • [47] Chemical shift artifact-free imaging: A new option in MRI?
    Weis, J
    Ericsson, A
    Hemmingsson, A
    MAGNETIC RESONANCE IMAGING, 1998, 16 (07) : 839 - 844
  • [48] Evolutionary Computational approach for artifact-free image reconstruction from reduced samples: Application to Fourier EMRI
    Sumathi, M.
    Krishna, Murali C.
    Murugesan, R.
    ICCIMA 2007: INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND MULTIMEDIA APPLICATIONS, VOL III, PROCEEDINGS, 2007, : 464 - +
  • [49] MICRO-ANGIODYNAMICS IN THE ARTIFACT-FREE MICRO-CIRCULATION
    COLANTUONI, A
    BERTUGLIA, S
    INTAGLIETTA, M
    GROSS, JF
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (03): : 265 - 266
  • [50] Artifact-free optical spin-orbit torque magnetometry
    Kim, Joo-Sung
    Park, Yong-Keun
    Whang, Hyun-Seok
    Park, Jung-Hyun
    Min, Byoung-Chul
    Choe, Sug-Bong
    APPLIED PHYSICS LETTERS, 2019, 114 (18)