RESTORING ARTIFACT-FREE MICROSCOPY IMAGE SEQUENCES

被引:0
|
作者
Yin, Zhaozheng [1 ]
Kanade, Takeo [1 ]
机构
[1] Carnegie Mellon Univ, Inst Robot, Pittsburgh, PA 15213 USA
关键词
Microscopy image analysis; image restoration; phase contrast; differential interference contrast;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Phase contrast and differential interference contrast, which are used to capture microscopy images of living cells, contain a few artifacts such as halo and shadow-cast effect. Removing these artifacts from microscopy images facilitates automated microscopy image analysis, such as the cell segmentation that is a critical step in cell tracking systems. We propose a restoration algorithm based on the microscopy imaging model and consider temporal consistency when restoring time-lapse microscopy image sequences. The artifact-free microscopy images are restored by minimizing a regularized quadratic cost function that is adaptable to input image properties. Our method achieves high segmentation accuracy and low computational cost compared to the previous methods.
引用
收藏
页码:909 / 913
页数:5
相关论文
共 50 条
  • [21] Understanding the phase contrast optics to restore artifact-free microscopy images for segmentation
    Yin, Zhaozheng
    Kanade, Takeo
    Chen, Mei
    MEDICAL IMAGE ANALYSIS, 2012, 16 (05) : 1047 - 1062
  • [22] Photonic lantern TIRF microscopy for highly efficient, uniform, artifact-free imaging
    Husain, Abdullah Husain
    Yerolatsitis, Stephanos
    Correa, Rodrigo Amezcua
    Han, Kyu Yuoung
    OPTICS EXPRESS, 2024, 32 (21): : 37046 - 37058
  • [23] Artifact-free cross-sections
    Erdman, N.
    Campbell, R.
    Asahina, S.
    ADVANCED MATERIALS & PROCESSES, 2006, 164 (07): : 54 - +
  • [24] Artifact-free reverse time migration
    Zhang, Lele
    Slob, Evert
    van der Neut, Joost
    Wapenaar, Kees
    GEOPHYSICS, 2018, 83 (05) : A65 - A68
  • [25] An extension to artifact-free projection overlaps
    Lin, Jianyu
    MEDICAL PHYSICS, 2015, 42 (05) : 2179 - 2193
  • [26] Artifact-free, penetration-adjustable elliptical-mirror-based TIRF microscopy
    Liu, Jian
    Kong, Chenqi
    Li, Qiang
    Zhao, Weisong
    Li, Mengzhou
    Gao, Shan
    Liu, Chenguang
    Tan, Jiubin
    OPTICS EXPRESS, 2018, 26 (20): : 26065 - 26079
  • [27] ARTIFACT-FREE MEASUREMENT OF ATTENUATION, IMPEDANCE AND DISPERSION
    COSTA, ET
    LEEMAN, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1987, 34 (03) : 391 - 391
  • [28] Artifact-free phase reconstruction for differential interference contrast microscopy based on deep learning
    Zhou, Chengxin
    Wang, Yuheng
    Liu, Yue
    Yu, Kun
    Liu, Yufang
    Zhong, Liyun
    Zhuang, Chunsheng
    Lu, Xiaoxu
    OPTICS EXPRESS, 2025, 33 (05): : 11887 - 11900
  • [29] Note: Quantitative (artifact-free) surface potential measurements using Kelvin force microscopy
    Melin, T.
    Barbet, S.
    Diesinger, H.
    Theron, D.
    Deresmes, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [30] TECHNIQUE FOR FIXATION OF ARTIFACT-FREE STRETCHED MYOCARDIUM
    BUTCHER, W
    MACKENZIE, WF
    TEXAS REPORTS ON BIOLOGY AND MEDICINE, 1975, 33 (02) : 346 - 346