Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery

被引:33
|
作者
Hirasawa, Kazunori [1 ,2 ,3 ,4 ,6 ]
Nakakura, Shunsuke [7 ]
Nakao, Yoshitaka [8 ]
Fujino, Yuri [1 ]
Matsuura, Masato [1 ,5 ]
Murata, Hiroshi [1 ]
Kiuchi, Yoshiaki [8 ]
Asaoka, Ryo [1 ]
机构
[1] Univ Tokyo Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
[3] UCL, Inst Ophthalmol, London, England
[4] Kitasato Univ, Sch Med, Dept Ophthalmol, Kanagawa, Japan
[5] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol, Kanagawa, Japan
[6] Kitasato Univ, Kanagawa, Japan
[7] Saneikai Tsukazaki Hosp, Dept Ophthalmol, Himeji, Hyogo, Japan
[8] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
基金
日本科学技术振兴机构;
关键词
ENDOTHELIAL-CELL LOSS; RESPONSE PARAMETERS; LENS IMPLANTATION; PHACOEMULSIFICATION; THICKNESS; HYSTERESIS; EYES; MICROINCISION; ORGANIZATION; KERATOCONUS;
D O I
10.1016/j.ajo.2018.07.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). DESIGN: Prospective, interventional case series study. METHODS: This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery (Pre) as well as 1 week (1W), 1 month (1M), and 3 months (3M) postsurgery. The following CST parameters were recorded: deformation amplitude max (DA max), DA ratio max 1 mm and 2 mm, integrated radius, stiffness parameter at applanation 1 (SP A1), Ambrosio relational thickness to the horizontal profile (ARTh), Corvis biomechanical index (CBI), central corneal thickness (CCT), noncorrected intraocular pressure (IOPnct), and biomechanically corrected IOP (bIOP). IOP was also measured with Goldmann applanation tonometry and the noncontact tonometer CT-90A. All measurements were compared at each period using the linear mixed model, with and without adjustment for bIOP and CCT. RESULTS: All IOP measurements decreased over time (P < .01). CCT was increased at 1W and 3M (P < .01), whereas ARTh was decreased at 1W and 1M (P < .01), but returned to its Pre level at 3M. DA max and Integrated radius were increased at 3M (P < .01), whereas SP A1 was decreased at 3M (P < .01). CBI was increased at 1W (P < .01), but returned to its Pre level at 1M. CONCLUSIONS: IOP and Corneal biomechanical properties are changed after cataract surgery. In particular, SP A1 decreases while DA max and integrated radius increase, even at 3M, suggesting a less stiff cornea. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [41] Corneal Biomechanics and Measurement of Intraocular Pressure Measurement in Pathological Corneas
    Luebke, Jan
    Maier, Philip Christian
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (06) : 751 - 755
  • [42] Modifications in Corneal Biomechanics and Intraocular Pressure After Deep Sclerectomy
    Iordanidou, Vasiliki
    Hamard, Pascale
    Gendron, Gael
    Labbe, Antoine
    Raphael, Mathilde
    Baudouin, Christophe
    JOURNAL OF GLAUCOMA, 2010, 19 (04) : 252 - 256
  • [43] Incidence of increased intraocular pressure on postoperative day 1 following cataract surgery
    Brauner, SC
    Ferrufino-Ponce, ZK
    Henderson, BA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [44] Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy
    Ibanez, J.
    Martinez, J.
    Perez, D.
    Sanchez, I.
    Idoate, A.
    Berniolles, J.
    Bartolome, I.
    Lopez, I.
    Ascaso Puyuelo, F. J.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [45] Large corneal epithelial detachment as a complication of wound burping to release aqueous humor for elevated intraocular pressure following cataract surgery
    Tsai, Jarryl H. J.
    Eong, Jonathan T. W. Au
    Eong, Kah-Guan Au
    JOURNAL OF SURGICAL CASE REPORTS, 2024, 2024 (06):
  • [46] Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery
    Ken Hayashi
    Motoaki Yoshida
    Koichi Yoshimura
    Japanese Journal of Ophthalmology, 2014, 58 : 402 - 408
  • [47] Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery
    Hayashi, Ken
    Yoshida, Motoaki
    Yoshimura, Koichi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (05) : 402 - 408
  • [48] Intraocular pressure changes before and after a femtosecond laser procedure for cataract surgery
    Chung, Ho Seok
    Lee, Hun
    Park, So young
    Min, Chan Hong
    Kim, Mose
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [49] Corneal perforation following cataract surgery with anterior chamber intraocular lens due to adherent leukoma
    Khmamouche, M.
    Zerrouk, R.
    Abaloune, Y.
    El Khoyaali, A.
    El Asri, F.
    Reda, K.
    Abdelbare, O.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (01): : 102 - 103
  • [50] The effect of heparin-coated intraocular lenses on intraocular pressure following combined trabeculectomy and cataract surgery
    Hugkulstone, CE
    Sadiq, SA
    Rubasingham, AS
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1997, 75 (04): : 437 - 440