Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery

被引:33
|
作者
Hirasawa, Kazunori [1 ,2 ,3 ,4 ,6 ]
Nakakura, Shunsuke [7 ]
Nakao, Yoshitaka [8 ]
Fujino, Yuri [1 ]
Matsuura, Masato [1 ,5 ]
Murata, Hiroshi [1 ]
Kiuchi, Yoshiaki [8 ]
Asaoka, Ryo [1 ]
机构
[1] Univ Tokyo Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
[3] UCL, Inst Ophthalmol, London, England
[4] Kitasato Univ, Sch Med, Dept Ophthalmol, Kanagawa, Japan
[5] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol, Kanagawa, Japan
[6] Kitasato Univ, Kanagawa, Japan
[7] Saneikai Tsukazaki Hosp, Dept Ophthalmol, Himeji, Hyogo, Japan
[8] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
基金
日本科学技术振兴机构;
关键词
ENDOTHELIAL-CELL LOSS; RESPONSE PARAMETERS; LENS IMPLANTATION; PHACOEMULSIFICATION; THICKNESS; HYSTERESIS; EYES; MICROINCISION; ORGANIZATION; KERATOCONUS;
D O I
10.1016/j.ajo.2018.07.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). DESIGN: Prospective, interventional case series study. METHODS: This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery (Pre) as well as 1 week (1W), 1 month (1M), and 3 months (3M) postsurgery. The following CST parameters were recorded: deformation amplitude max (DA max), DA ratio max 1 mm and 2 mm, integrated radius, stiffness parameter at applanation 1 (SP A1), Ambrosio relational thickness to the horizontal profile (ARTh), Corvis biomechanical index (CBI), central corneal thickness (CCT), noncorrected intraocular pressure (IOPnct), and biomechanically corrected IOP (bIOP). IOP was also measured with Goldmann applanation tonometry and the noncontact tonometer CT-90A. All measurements were compared at each period using the linear mixed model, with and without adjustment for bIOP and CCT. RESULTS: All IOP measurements decreased over time (P < .01). CCT was increased at 1W and 3M (P < .01), whereas ARTh was decreased at 1W and 1M (P < .01), but returned to its Pre level at 3M. DA max and Integrated radius were increased at 3M (P < .01), whereas SP A1 was decreased at 3M (P < .01). CBI was increased at 1W (P < .01), but returned to its Pre level at 1M. CONCLUSIONS: IOP and Corneal biomechanical properties are changed after cataract surgery. In particular, SP A1 decreases while DA max and integrated radius increase, even at 3M, suggesting a less stiff cornea. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [21] Intraocular Pressure Changes and Relationship With Corneal Biomechanics After SMILE and FS-LASIK
    Li, Hua
    Wang, Yan
    Dou, Rui
    Wei, Pinghui
    Zhang, Jiamei
    Zhao, Wei
    Li, Liuyang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (10) : 4180 - 4186
  • [22] A novel index for predicting intraocular pressure reduction following cataract surgery
    Issa, SA
    Pacheco, J
    Mahmood, U
    Nolan, J
    Beatty, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (05) : 543 - 546
  • [23] Changes in mtraocular pressure following cataract surgery in dogs
    Nair, S. S.
    Vasanth, M. S.
    INDIAN VETERINARY JOURNAL, 2007, 84 (05): : 525 - 526
  • [24] INTRAOCULAR PRESSURE FOLLOWING CATARACT EXTRACTION
    GALIN, MA
    PERRY, R
    BARAS, I
    ARCHIVES OF OPHTHALMOLOGY, 1961, 66 (01) : 80 - &
  • [25] Cataract surgery and intraocular pressure in glaucoma
    Young, Cara E. Capitena
    Seibold, Leonard K.
    Kahook, Malik Y.
    CURRENT OPINION IN OPHTHALMOLOGY, 2020, 31 (01) : 15 - 22
  • [26] Cataract surgery to lower intraocular pressure
    Berdahl, John P.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2009, 16 (03) : 119 - 122
  • [27] Changes of intraocular pressure after cataract surgery in myopic and emmetropic patients
    Lv, Huibin
    Yang, Jiarui
    Liu, Yushi
    Jiang, Xiaodan
    Liu, Yan
    Zhang, Mingzhou
    Wang, Yuexin
    Song, Hang
    Li, Xuemin
    MEDICINE, 2018, 97 (38)
  • [28] Effect of high pressurization versus normal pressurization on changes in intraocular pressure immediately after clear corneal cataract surgery
    Hayashi, Ken
    Yoshida, Motoaki
    Manabe, Shin-ichi
    Yoshimura, Koichi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01): : 87 - 94
  • [29] Association between corneal hysteresis and the magnitude of intraocular pressure decrease after cataract surgery
    Deol, Madhvi
    Ehrlich, Joshua R.
    Shimmyo, Mitsugu
    Radcliffe, Nathan M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1176 - 1181
  • [30] Central corneal thickness and intraocular pressure changes after congenital cataract surgery with intraocular lens implantation in children younger than 2 years
    Sukhija, Jaspreet
    Kaur, Savleen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (05): : 662 - 666