Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery

被引:33
|
作者
Hirasawa, Kazunori [1 ,2 ,3 ,4 ,6 ]
Nakakura, Shunsuke [7 ]
Nakao, Yoshitaka [8 ]
Fujino, Yuri [1 ]
Matsuura, Masato [1 ,5 ]
Murata, Hiroshi [1 ]
Kiuchi, Yoshiaki [8 ]
Asaoka, Ryo [1 ]
机构
[1] Univ Tokyo Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
[3] UCL, Inst Ophthalmol, London, England
[4] Kitasato Univ, Sch Med, Dept Ophthalmol, Kanagawa, Japan
[5] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol, Kanagawa, Japan
[6] Kitasato Univ, Kanagawa, Japan
[7] Saneikai Tsukazaki Hosp, Dept Ophthalmol, Himeji, Hyogo, Japan
[8] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
基金
日本科学技术振兴机构;
关键词
ENDOTHELIAL-CELL LOSS; RESPONSE PARAMETERS; LENS IMPLANTATION; PHACOEMULSIFICATION; THICKNESS; HYSTERESIS; EYES; MICROINCISION; ORGANIZATION; KERATOCONUS;
D O I
10.1016/j.ajo.2018.07.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). DESIGN: Prospective, interventional case series study. METHODS: This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery (Pre) as well as 1 week (1W), 1 month (1M), and 3 months (3M) postsurgery. The following CST parameters were recorded: deformation amplitude max (DA max), DA ratio max 1 mm and 2 mm, integrated radius, stiffness parameter at applanation 1 (SP A1), Ambrosio relational thickness to the horizontal profile (ARTh), Corvis biomechanical index (CBI), central corneal thickness (CCT), noncorrected intraocular pressure (IOPnct), and biomechanically corrected IOP (bIOP). IOP was also measured with Goldmann applanation tonometry and the noncontact tonometer CT-90A. All measurements were compared at each period using the linear mixed model, with and without adjustment for bIOP and CCT. RESULTS: All IOP measurements decreased over time (P < .01). CCT was increased at 1W and 3M (P < .01), whereas ARTh was decreased at 1W and 1M (P < .01), but returned to its Pre level at 3M. DA max and Integrated radius were increased at 3M (P < .01), whereas SP A1 was decreased at 3M (P < .01). CBI was increased at 1W (P < .01), but returned to its Pre level at 1M. CONCLUSIONS: IOP and Corneal biomechanical properties are changed after cataract surgery. In particular, SP A1 decreases while DA max and integrated radius increase, even at 3M, suggesting a less stiff cornea. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [1] Factors influencing intraocular pressure, corneal thickness and corneal biomechanics after congenital cataract surgery
    Faramarzi, Amir
    Feizi, Sepehr
    Maghsoodlou, Ali
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (11) : 1493 - 1499
  • [2] Impacts and Correlations on Corneal Biomechanics, Corneal Optical Density and Intraocular Pressure after Cataract Surgery
    Lin, Fang-Yang
    Ho, Ren-Wen
    Yu, Hun-Ju
    Yang, I-Hui
    Fang, Po-Chiung
    Kuo, Ming-Tse
    DIAGNOSTICS, 2024, 14 (14)
  • [3] Corneal biomechanics and intraocular pressure changes after uneventful phacoemulsification surgery
    Ahmed, Marwa S. A.
    Hassanin, Olfat A.
    Abou El-Enin, Ahmed I.
    Rashwan, Afaf H.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2019, 112 (04) : 145 - 153
  • [4] Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
    Pepose, Jay S.
    Feigenbaum, Susan K.
    Qazi, Mujtaba A.
    Sanderson, Jeffrey P.
    Roberts, Cynthia J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (01) : 39 - 47
  • [5] Effects of water drinking on corneal biomechanics: The association with intraocular pressure changes
    Vera, Jesus
    Redondo, Beatriz
    Molin, Ruben
    Jimenez, Raimundo
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1222 - 1228
  • [6] Discussion of Changes in Intraocular Pressure and Anterior Segment Morphometry Following Phacoemulsification Cataract Surgery
    Dooley, Ian
    Beatty, Stephen
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 949 - 950
  • [7] Early postoperative intraocular pressure elevation following cataract surgery
    Grzybowski, Andrzej
    Kanclerz, Piotr
    CURRENT OPINION IN OPHTHALMOLOGY, 2019, 30 (01) : 56 - 62
  • [8] Cataract Surgery and Intraocular Pressure
    Melancia, Diana
    Pinto, Luis Abegao
    Marques-Neves, Carlos
    OPHTHALMIC RESEARCH, 2015, 53 (03) : 141 - 148
  • [9] Cataract surgery for congenital cataract: Endothelial cell characteristics, corneal thickness, and impact on intraocular pressure
    Nilforushan, Naveed
    Falavarjani, Khalil Ghasemi
    Razeghinejad, Mohammad Reza
    Bakhtiari, Pejman
    JOURNAL OF AAPOS, 2007, 11 (02): : 159 - 161
  • [10] Discussion of Changes in Intraocular Pressure and Anterior Segment Morphometry Following Phacoemulsification Cataract Surgery reply
    Lin, Shan C.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 950 - 950