Reduce Leakage Currents in Transformer less PVSystem Connected to Utility Grid with H-Bridge Inverter Topology

被引:0
|
作者
Jyothi, Boga [1 ,2 ]
Vinnakoti, Sudheer [3 ]
Varaprasad, Madisa V. G. [1 ]
机构
[1] Vignans Inst Informat Technol, Visakhapatnam, Andhra Pradesh, India
[2] Koneru Lakshmaiah Educ Fdn, Vijayawada, Andhra Pradesh, India
[3] RAGHU Engn Coll, Visakhapatnam, Andhra Pradesh, India
关键词
solar energy; Maximum power point tracking; H-Bridge inverter; Bi-polar PWM; LCL Filter topology;
D O I
10.1109/ICAECT54875.2022.9807952
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Renewable energy is becoming a necessity as alternative forms of energy generation are needed to meet the world's energy demands. In this report, the three main current PV system configurations will be discussed and compared in terms of cost, reliability and performance. There are different topologies introduced in grid connected pv system with transformer and transformer less. There exist transformer between pv array and grid in previously so there exist galvanic isolation. The main problem with using transformer resonance due to thus transformer and harmonics injected in grid because of these DC spillage current infused into the network may cause saturation of core in transformer at distribution side and it cause overheating and failure. Stray capacitance in between pv array and ground the spillage current flow through this. Different inverter topologies reduce leakage currents that are half-bridge and full- bridge topologies, with bipolar pulse width modulation have been proposed. In this project proposed high- efficient topology these generate no common varying mode voltage and require low input voltage as bipolar pwm full bridge. In these bipolar pwm with using LCL filter topology is used to reduce leakage currents between PV array and grid. In these DC-AC inverter displayed with H-Bridge protected Gate Bipolar Semiconductor module which is controlled utilizing bipolar PWM strategy. There using the MPPT Technique of perturb and observe to absorb maximum amount of power from PV system. In these PLL is utilize to keep up synchronize the voltage, current, frequency in phase with the grid. These current and voltage regulators are used to analyze the reference voltage is acquired from the inverter active current and reactive current is zero.By using PI and FUZZY current controller to reduce total harmonic distortion with using fuzzy current controller is better than PI to improve power quality.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Robust Active and Reactive Power Control by using Single-Phase Grid connected H-Bridge Inverter
    Coteli, Resul
    Kayisli, Korhan
    Caglayan, Ruhi Zafer
    12TH INTERNATIONAL CONFERENCE ON SMART GRID, ICSMARTGRID 2024, 2024, : 614 - 617
  • [42] Closed loop Control of Novel Transformer-less Inverter Topology for Single Phase Grid Connected Photovoltaic system
    Rajeev, Mini
    Agarwal, Vivek
    2016 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2016,
  • [43] HF Transformer Based Grid-Connected Inverter Topology for Photovoltaic Systems
    Kulkarni, Abhijit
    John, Vinod
    IETE TECHNICAL REVIEW, 2016, 33 (01) : 69 - 75
  • [44] Model Predictive Control for Asymmetrical Cascaded H-Bridge Multilevel Grid-Connected Inverter with Flying Capacitor
    Han, Jingang
    Yang, Tengfei
    Peng, Dongkai
    Wang, Tianzhen
    Yao, Gang
    IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 1611 - 1616
  • [45] Simulation of SVPWM Based 3-level H-bridge Inverter Used in Grid Connected PV System
    Shukla, Darshni M.
    Zaveri, Naimish
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON GREEN ENERGY FOR SUSTAINABLE DEVELOPMENT (ICUE 2018), 2018,
  • [46] A Simplified Predictive Current Controlled Cascaded H-Bridge Multilevel Inverter for Grid-Connected Photovoltaic Systems
    Ghassemi, R.
    Abbaszadeh, K.
    2015 6TH POWER ELECTRONICS, DRIVES SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC), 2015, : 213 - 217
  • [47] Control of a Single-Phase Cascaded H-Bridge Multilevel Inverter for Grid-Connected Photovoltaic Systems
    Villanueva, Elena
    Correa, Pablo
    Rodriguez, Jose
    Pacas, Mario
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) : 4399 - 4406
  • [48] Modeling and control of a novel transformer-less dynamic voltage restorer based on H-bridge cascaded multilevel inverter
    Wang, Songcen
    Tang, Guangfu
    Yu, Kunshan
    Zheng, Jianchao
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 726 - 734
  • [49] Concept of a distributed photovoltaic multilevel inverter with cascaded double H-bridge topology
    Goetz, Stefan M.
    Wang, Chuang
    Li, Zhongxi
    Murphy, David L. K.
    Peterchev, Angel V.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 : 667 - 678
  • [50] Comparison between a Cascaded H-Bridge and a Conventional H-Bridge for a 5-kW Grid-Tied Solar Inverter
    Bertin, Thibault
    Despesse, Ghislain
    Thomas, Remy
    ELECTRONICS, 2023, 12 (08)