Reduce Leakage Currents in Transformer less PVSystem Connected to Utility Grid with H-Bridge Inverter Topology

被引:0
|
作者
Jyothi, Boga [1 ,2 ]
Vinnakoti, Sudheer [3 ]
Varaprasad, Madisa V. G. [1 ]
机构
[1] Vignans Inst Informat Technol, Visakhapatnam, Andhra Pradesh, India
[2] Koneru Lakshmaiah Educ Fdn, Vijayawada, Andhra Pradesh, India
[3] RAGHU Engn Coll, Visakhapatnam, Andhra Pradesh, India
关键词
solar energy; Maximum power point tracking; H-Bridge inverter; Bi-polar PWM; LCL Filter topology;
D O I
10.1109/ICAECT54875.2022.9807952
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Renewable energy is becoming a necessity as alternative forms of energy generation are needed to meet the world's energy demands. In this report, the three main current PV system configurations will be discussed and compared in terms of cost, reliability and performance. There are different topologies introduced in grid connected pv system with transformer and transformer less. There exist transformer between pv array and grid in previously so there exist galvanic isolation. The main problem with using transformer resonance due to thus transformer and harmonics injected in grid because of these DC spillage current infused into the network may cause saturation of core in transformer at distribution side and it cause overheating and failure. Stray capacitance in between pv array and ground the spillage current flow through this. Different inverter topologies reduce leakage currents that are half-bridge and full- bridge topologies, with bipolar pulse width modulation have been proposed. In this project proposed high- efficient topology these generate no common varying mode voltage and require low input voltage as bipolar pwm full bridge. In these bipolar pwm with using LCL filter topology is used to reduce leakage currents between PV array and grid. In these DC-AC inverter displayed with H-Bridge protected Gate Bipolar Semiconductor module which is controlled utilizing bipolar PWM strategy. There using the MPPT Technique of perturb and observe to absorb maximum amount of power from PV system. In these PLL is utilize to keep up synchronize the voltage, current, frequency in phase with the grid. These current and voltage regulators are used to analyze the reference voltage is acquired from the inverter active current and reactive current is zero.By using PI and FUZZY current controller to reduce total harmonic distortion with using fuzzy current controller is better than PI to improve power quality.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Classification of Grid Connected Transformer less PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families
    Ozkan, Ziya
    Hava, Ahmet M.
    JOURNAL OF POWER ELECTRONICS, 2015, 15 (01) : 256 - 267
  • [32] Distributed Generation Grid-Connected Converter Testing Device Based on Cascaded H-Bridge Topology
    Li, Yufei
    Wang, Yue
    Wang, Ruiming
    Wu, Jinlong
    Zhang, Hailong
    Feng, Yupeng
    Li, Shaolin
    Yao, Weizheng
    Li, Ben Q.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (04) : 2143 - 2154
  • [33] A Seven Level Cascaded H-Bridge Inverter Topology with Reduced Sources
    Sahoo, Rajanikanta
    Kasari, Prabir Ranjan
    Mishra, Manas Ranjan
    Chakraborti, Abanishwar
    Kumar, Ambati Dinesh
    Das, Bikram
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON INVENTIVE SYSTEMS AND CONTROL (ICISC 2018), 2018, : 655 - 660
  • [34] Component Count Reduced, Filter-Less H-Bridge Multilevel Inverter with Series and Parallel Connected Switches
    Vijayakumar, M.
    Ramesh, S. M.
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2021, 30 (03)
  • [35] A Novel Bidirectional Transformer-less Grid-connected Inverter with Common-Mode leakage current suppression
    Liu, Zhuoran
    Liang, Mei
    Tian, Kai
    Yang, Xiaobo
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 1292 - 1297
  • [36] Harmonic suppression control strategy of cascaded H-bridge grid-connected photovoltaic inverter under grid voltage distortion
    Yuan, Yisheng
    Lü, Sen
    Zhu, Qihang
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (03): : 68 - 75
  • [37] A hybrid control topology for cascaded H-bridge multilevel inverter to improve the power quality of smart grid connected system: NBO-RERNN approach
    Rajesh, C. R.
    Meenalochini, P.
    Kannaiah, Sathish Kumar
    Bindu, A.
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 238
  • [38] Modeling and Control of the Single-Phase Photovoltaic Grid-Connected Cascaded H-Bridge Multilevel Inverter
    Lee, S. J.
    Bae, H. S.
    Cho, B. H.
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 43 - 47
  • [39] Decoupled Active and Reactive Power Control of Cascaded H-Bridge PV Inverter for Grid-Connected Applications
    Sridhar, V.
    Umashankar, S.
    Sanjeevikumar, P.
    ADVANCES IN SMART GRID AND RENEWABLE ENERGY, 2018, 435 : 315 - 323
  • [40] Islanding and resynchronization process of a grid-connected microgrid with series transformerless H-bridge inverter installed at PCC
    Salem, Qusay
    Liu, Libo
    Xie, Jian
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,