A Technique Based on an Archimedean Copula for the Localization of Partial Discharge in a Transformer Winding

被引:20
|
作者
Mondal, Mithun [1 ]
Kumbhar, G. B. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Elect Engn, Roorkee, Uttar Pradesh, India
关键词
Power transformers; PD localization; correlation; Archimedean copula; FREQUENCY-RESPONSE DATA; POWER TRANSFORMERS; LOCATION; IDENTIFICATION; MODEL;
D O I
10.1109/TDEI.2016.7736852
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Precise localization of a Partial Discharge (PD) source inside a winding is one of the important tasks for early detection and prevention of catastrophic failure of a transformer. However, due to the highly complex structures of the windings and statistical nature of PD, the exact location of a PD source is quite difficult to discover. In this paper, a technique based on an Archimedean copula is proposed to find the location of a PD source in a transformer winding. The winding responses to the PD signals of known pulse-widths applied at all the sections are taken as reference data. Further, the winding responses, obtained from the PD pulses of random shapes and magnitudes applied across various sections of the winding, are taken as test data. To predict the location of the test signals, the best-fit copula and its parameters are established using the reference and test data. The maximum value of log-likelihood between the reference data and the test signal indicates the location of the PD source. Firstly, simulation case-studies are conducted to demonstrate how the proposed approach can be implemented to locate the PD source. The results of the proposed method are then compared with the time-domain and frequency-domain based correlation techniques. Finally, the proposed method is tested with experimental data acquired from a laboratory scale model of the transformer winding. The simulation and experimental results demonstrate that the proposed approach is capable of achieving an accurate prediction of the location of the PD source.
引用
收藏
页码:2908 / 2916
页数:9
相关论文
共 50 条
  • [31] A Transformer Partial Discharge UHF Localization Method Based on TDOA and TS-PSO
    Li M.
    Feng X.
    Man X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (06): : 1834 - 1842
  • [32] An algorithm for partial discharge localization in transformers using winding design data
    Jafari, A. Mazhab
    Akbari, A.
    Mirzaei, H. R.
    Kharezi, M.
    Allahbakhshi, A.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 919 - +
  • [33] Convenient Online Approach to Multisource Partial Discharge Localization in Transformer
    Cai, Junyi
    Zhou, Lijun
    Zhang, Yulin
    Wang, Dongyang
    Liao, Wei
    Zhang, Chenqingyu
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (09) : 9440 - 9450
  • [34] Investigating suitable features for Partial Discharge localization in power transformer
    Homaei, M.
    Jafari, A. Mazhab
    Akbari, A.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 923 - +
  • [35] Modeling of Partial Discharge in Transformer Winding by Multi-Conductor Transmission Line Model
    Hosseini, S. M. Hassan
    Vakilian, M.
    Niasar, M. Ghaffarian
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (02): : 3926 - 3934
  • [36] Construction of Finite Impulse Wavelet Filter for Partial Discharge Localisation inside a Transformer Winding
    Abd Rahman, M. S.
    Rapisarda, P.
    Lewin, P. L.
    2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 30 - 34
  • [37] A comparison between partial discharge propagation in multiple-α and single-α transformer winding
    Naderi, MS
    Vakilian, M
    Blackburn, TR
    Phung, BT
    Zhang, H
    O, HN
    Naderi, MS
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING CONFERENCE, 2005, : 108 - 111
  • [38] Partial Discharge Propagation inside a High Voltage Transformer Winding: Comparison of Measurement and Simulation
    Abd Rahman, M. S.
    Rapisarda, P.
    Lewin, P. L.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 56 - 59
  • [39] Comparing the New Improved RLC and CMTL Models for Measuring Partial Discharge in Transformer Winding
    Baravati, Peyman Rezaei
    Hosseini, Seyed Mohammad Hassan
    Moazzami, Majid
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [40] Study of partial discharge localization using ultrasonics in power transformer based on particle swarm optimization
    Tang, Lijun
    Luo, Richeng
    Deng, Min
    Su, Jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (02) : 492 - 495