A Technique Based on an Archimedean Copula for the Localization of Partial Discharge in a Transformer Winding

被引:20
|
作者
Mondal, Mithun [1 ]
Kumbhar, G. B. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Elect Engn, Roorkee, Uttar Pradesh, India
关键词
Power transformers; PD localization; correlation; Archimedean copula; FREQUENCY-RESPONSE DATA; POWER TRANSFORMERS; LOCATION; IDENTIFICATION; MODEL;
D O I
10.1109/TDEI.2016.7736852
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Precise localization of a Partial Discharge (PD) source inside a winding is one of the important tasks for early detection and prevention of catastrophic failure of a transformer. However, due to the highly complex structures of the windings and statistical nature of PD, the exact location of a PD source is quite difficult to discover. In this paper, a technique based on an Archimedean copula is proposed to find the location of a PD source in a transformer winding. The winding responses to the PD signals of known pulse-widths applied at all the sections are taken as reference data. Further, the winding responses, obtained from the PD pulses of random shapes and magnitudes applied across various sections of the winding, are taken as test data. To predict the location of the test signals, the best-fit copula and its parameters are established using the reference and test data. The maximum value of log-likelihood between the reference data and the test signal indicates the location of the PD source. Firstly, simulation case-studies are conducted to demonstrate how the proposed approach can be implemented to locate the PD source. The results of the proposed method are then compared with the time-domain and frequency-domain based correlation techniques. Finally, the proposed method is tested with experimental data acquired from a laboratory scale model of the transformer winding. The simulation and experimental results demonstrate that the proposed approach is capable of achieving an accurate prediction of the location of the PD source.
引用
收藏
页码:2908 / 2916
页数:9
相关论文
共 50 条
  • [21] Distance function locating partial discharge in single phase transformer winding based on MTL model
    North China Electric Power University, Baoding 071003, China
    不详
    Diangong Jishu Xuebao, 2006, 1 (115-120):
  • [22] Partial Discharge Detection and Localization in Power Transformer Windings
    Abdul-Malek, Zulkurnain
    Aziz, Mohammed Abd Ali
    Aziz, Ali Saleh
    Mechanical and Materials Engineering, 2014, 554 : 578 - 582
  • [23] Ultrasonic localization of Partial Discharge in Power Transformer Based on Improved Genetic Algorithm
    Ren, Shuangzan
    Yang, Xu
    Zhu, Ruihua
    Xi, Baofeng
    Cao, Xiaolong
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 99 - 99
  • [24] Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques
    Hosseini, Seyed Mohammad Hassan
    Baravati, Peyman Rezaei
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (03) : 1093 - 1101
  • [25] Transformer Winding Modeling based on Multi-Conductor Transmission Line Model for Partial Discharge Study
    Hosseini, Seyed Mohammad Hassan
    Baravati, Peyman Rezaei
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (01) : 154 - 161
  • [26] Partial discharge location using a hybrid transformer winding model with morphology-based noise removal
    Ji, T. Y.
    Tang, W. H.
    Wu, Q. H.
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 101 : 9 - 16
  • [27] Influence of different adhesives on partial discharge in power transformer winding cylinder insulation
    Indarto, Agus
    Murti, Ardhyan Wisnu
    Husnayain, Faiz
    Garniwa, Iwa
    Rahardjo, Amien
    Hudaya, Chairul
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (03) : 964 - 970
  • [28] Study on the influence of pulse propagation in transformer winding on partial discharge pattern recognition
    Gao, WS
    Tan, KX
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 125 - 128
  • [29] Online Detection of Partial Discharge inside Power Transformer Winding Through IFRA
    Mohseni, Bahar
    Hashemnia, Naser
    Islam, Syed
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [30] A Correction-Iteration Method for Partial Discharge Localization in Transformer Based on Acoustic Measurement
    Zhou, Lijun
    Cai, Junyi
    Hu, Junjie
    Lang, Guangya
    Guo, Lei
    Wei, Liao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1571 - 1581