The application of voxel phantoms to the internal dosimetry of radionuclides

被引:65
|
作者
Zankl, M [1 ]
Petoussi-Henss, N [1 ]
Fill, U [1 ]
Regulla, D [1 ]
机构
[1] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a006299
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Extensive calculations of specific absorbed fractions (SAFs) for monoenergetic photon sources were performed using a Monte Carlo photon transport code together with seven male and female adult voxel models based on computed tomographic data of real persons. These models offer greater realism with respect to organ topology than the mathematical phantoms commonly used in the past. Due to individual anatomical differences, large variations in photon SAFs between the voxel models were found that can amount to orders of magnitude for very low photon energies. However. in many cases, the larger differences were found between MIRD-type and voxel models. since the inter-organ distances tend to be larger in the MIRD-type phantoms than in reality, due to over-simplification of organ shapes. Furthermore. organ absorbed doses per incorporated activity were evaluated for two selected radiopharmaceuticals. Although a method was found to largely eliminate the influence of organ mass on SAFs for organ self-absorption, the absorbed dose coefficients varied by several tens of per cent between the individual voxel models. thus indicating a significant influence of individual photon SAFs for organ cross-fire on organ absorbed dose. Again, 43% of the MIRD organ dose values were outside the range of doses spanned by the voxel models. Effective dose showed a variation of only up to 26% between the single voxel models for the radiopharmaceuticals considered.
引用
收藏
页码:539 / 548
页数:10
相关论文
共 50 条
  • [21] Monte Carlo studies in the field of internal dosimetry of incorporated radionuclides
    Gualdrini, G
    COMPUTING RADIATION DOSIMETRY - CRD 2002, WORKSHOP PROCEEDINGS, 2004, : 125 - 146
  • [22] Comparison of internal radiation doses estimated by MIRD and voxel techniques for a "family" of phantoms
    Smith, T
    Petoussi-Henss, N
    Zankl, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (09) : 1387 - 1398
  • [23] Comparison of internal radiation doses estimated by MIRD and voxel techniques for a "family" of phantoms
    Terry Smith
    Nina Petoussi-Henss
    Maria Zankl
    European Journal of Nuclear Medicine, 2000, 27 : 1387 - 1398
  • [24] Stylized versus voxel phantoms: quantification of internal organ chord length distances
    Coleman, D.
    Griffin, K. T.
    Dewji, S. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05):
  • [25] Computational Internal Dosimetry Methods as Applied to the UF Series of Hybrid Phantoms
    Wayson, M.
    Lee, C.
    Sgouros, G.
    Bolch, W.
    MEDICAL PHYSICS, 2011, 38 (06) : 3408 - +
  • [26] Internal dosimetry estimates using voxelized reference phantoms for thyroid agents
    Hoseinian-Azghadi, E.
    Rafat-Motavalli, L.
    Miri-Hakimabad, H.
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (03) : 407 - 422
  • [27] Comparative analysis of the conversion coefficient for internal dosimetry using different phantoms
    Batista de Lacerda, Isabelle Viviane
    Vieira, Jose Wilson
    Oliveira, Mercia Liane
    de Andrade Lima, Fernando Roberto
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [28] The GSF family of voxel phantoms
    Petoussi-Henss, N
    Zankl, M
    Fill, U
    Regulla, D
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01): : 89 - 106
  • [29] Voxel-based Internal Dosimetry Using Deep Residual Learning
    Kim, K.
    Lee, M.
    Suh, M.
    Cheon, G.
    Lee, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S398 - S398
  • [30] Optimized Monte Carlo simulations for voxel-based internal dosimetry
    Cordeiro, Leanderson P.
    de Sa, Lidia, V
    Kitamikado, Rafael A.
    Sapienza, Marcelo T.
    Bonifacio, Daniel A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):