Internal dosimetry estimates using voxelized reference phantoms for thyroid agents

被引:11
|
作者
Hoseinian-Azghadi, E. [1 ]
Rafat-Motavalli, L. [1 ]
Miri-Hakimabad, H. [1 ]
机构
[1] Ferdowsi Univ Mashhad, Sch Sci, Dept Phys, Mashhad 917751436, Iran
关键词
internal dosimetry; thyroid agents; voxel phantoms; Monte-Carlo method;
D O I
10.1093/jrr/rrt125
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for (131)Iodine, (123)Iodine and Tc-99m incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0-55% was made, and the effect of various techniques for administration of Tc-99m on organ doses was studied. To investigate the necessity of calculating organ dose from all source regions, the major source organ and its contribution to total dose were specified for each target organ. Moreover, we compared effective dose in ICRP voxel phantoms with that in stylized phantoms. In our method, we directly calculated the organ dose without using the S values or SAFs, as is commonly done. Hence, a distribution of the absorbed dose to entire tissues was obtained. The chord length distributions (CLDs) were also computed for the selected source-target pairs to make comparison across the genders. The results showed that the S values for radionuclides in the thyroid are not sufficient for calculating the organ doses, especially for I-123 and Tc-99m. The thyroid and its neighboring organs receive a greater dose as thyroid uptake increases. Our comparisons also revealed an underestimation of organ doses reported for the stylized phantoms compared with the values based on the ICRP voxel phantoms in the uptake range of 5-55%, and an overestimation of absorbed dose by up to 2-fold for Iodine administration using blocking agent and for Tc-99m incorporation.
引用
收藏
页码:407 / 422
页数:16
相关论文
共 50 条
  • [1] Voxelized Breast Phantoms for Dosimetry in Mammography
    Tucciariello, R.
    Barca, P.
    Sarto, D.
    Lamastra, R.
    Mettivier, G.
    Retico, A.
    Russo, P.
    Sarno, A.
    Traino, A.
    Fantacci, M.
    PROCEEDINGS OF THE 14TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 3: BIOINFORMATICS, 2021, : 154 - 161
  • [2] Geant4/GATE Comparison of Geometry Optimization Algorithms for Internal Dosimetry Using Voxelized Phantoms
    Kaddouch, S.
    El Khayati, N.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2020, 17 (01) : 97 - 107
  • [3] Geant4/GATE Comparison of Geometry Optimization Algorithms for Internal Dosimetry Using Voxelized Phantoms
    S. Kaddouch
    N. El Khayati
    Physics of Particles and Nuclei Letters, 2020, 17 : 97 - 107
  • [4] New Radiation Dosimetry Estimates for [18F]FLT based on Voxelized Phantoms
    Mendes, B. M.
    Ferreira, A., V
    Nascimento, L. T. C.
    Ferreira, S. M. Z. M. D.
    Silveira, M. B.
    Silva, J. B.
    RADIATION RESEARCH, 2018, 190 (01) : 37 - 44
  • [5] PET image reconstruction and dosimetry from voxelized phantoms with GATE
    Lorduy-Alos, Maria
    de Andrade, Pedro H. Avelino
    Pena-Acosta, Miriam Magela
    Gallardo, Sergio
    Verdu, Gumersindo
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [6] CALCULATION OF CONVERSION COEFFICIENTS FOR VOXELIZED PHANTOMS FOR CRITICALITY ACCIDENT DOSIMETRY
    Chevallier, M-A
    Pontier, J. B.
    Morin, H.
    Duluc, M.
    Evo, S.
    Letang, E.
    Trompier, F.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (01) : 9 - 24
  • [7] Iodine Internal Dosimetry using Anthropomorphic Voxelized Phantom in GATE
    Cavedini, N. G.
    Dartora, C. M.
    Marques da Silva, A. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S480 - S480
  • [8] Internal Dosimetry Comparison between Computational Voxelized Human Phantoms and Patient-Specific CT images
    Huang, Shih-ying
    Liu, Jiamin
    Yao, Jack
    Summers, Ronald
    Seo, Youngho
    Lee, Choonsik
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [9] Statistical Phantoms and Determining the Uncertainty of the Thyroid Mathematical Phantom in Internal Dosimetry Using the Monte Carlo Method
    Vahid Ragheb
    Zahra Sajjadi
    Saeed Mohammadi
    Journal of the Korean Physical Society, 2020, 77 : 1075 - 1081
  • [10] Statistical Phantoms and Determining the Uncertainty of the Thyroid Mathematical Phantom in Internal Dosimetry Using the Monte Carlo Method
    Ragheb, Vahid
    Sajjadi, Zahra
    Mohammadi, Saeed
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (12) : 1075 - 1081