Internal dosimetry estimates using voxelized reference phantoms for thyroid agents

被引:11
|
作者
Hoseinian-Azghadi, E. [1 ]
Rafat-Motavalli, L. [1 ]
Miri-Hakimabad, H. [1 ]
机构
[1] Ferdowsi Univ Mashhad, Sch Sci, Dept Phys, Mashhad 917751436, Iran
关键词
internal dosimetry; thyroid agents; voxel phantoms; Monte-Carlo method;
D O I
10.1093/jrr/rrt125
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for (131)Iodine, (123)Iodine and Tc-99m incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0-55% was made, and the effect of various techniques for administration of Tc-99m on organ doses was studied. To investigate the necessity of calculating organ dose from all source regions, the major source organ and its contribution to total dose were specified for each target organ. Moreover, we compared effective dose in ICRP voxel phantoms with that in stylized phantoms. In our method, we directly calculated the organ dose without using the S values or SAFs, as is commonly done. Hence, a distribution of the absorbed dose to entire tissues was obtained. The chord length distributions (CLDs) were also computed for the selected source-target pairs to make comparison across the genders. The results showed that the S values for radionuclides in the thyroid are not sufficient for calculating the organ doses, especially for I-123 and Tc-99m. The thyroid and its neighboring organs receive a greater dose as thyroid uptake increases. Our comparisons also revealed an underestimation of organ doses reported for the stylized phantoms compared with the values based on the ICRP voxel phantoms in the uptake range of 5-55%, and an overestimation of absorbed dose by up to 2-fold for Iodine administration using blocking agent and for Tc-99m incorporation.
引用
收藏
页码:407 / 422
页数:16
相关论文
共 50 条
  • [41] Multi-scale dosimetry with multi-scale Chinese reference phantoms
    Qiu, Rui
    Wu, Zhen
    Li, Chunyan
    Ren, Li
    Wang, Wenjing
    Ma, Ruiyao
    Hu, An Kang
    Zhu, Hongyu
    Li, Junli
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [42] The ICRP Reference Pediatric Phantoms - Design, Construction, and Applications to Nuclear Medicine Dosimetry
    Bolch, W.
    Lee, C.
    Zankl, M.
    Jokisch, D.
    Petoussi-Henss, N.
    Kim, C.
    Hunt, J.
    Sato, T.
    Eckerman, K.
    Kim, K.
    Li, J.
    Schlattl, H.
    Yeom, Y.
    Wayson, M.
    Pafundi, D.
    Stepusin, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S79 - S79
  • [43] Construction of Taiwanese Adult Reference Phantoms for Internal Dose Evaluation
    Chang, Shu-Jun
    Hung, Shih-Yen
    Liu, Yan-Lin
    Jiang, Shiang-Huei
    PLOS ONE, 2016, 11 (09):
  • [44] OEDIPE: SOFTWARE FOR FAST CONSTRUCTION OF COMPUTATIONAL PHANTOMS AND MCNPX CALCULATION IN INTERNAL DOSIMETRY
    Lamart, S.
    Robert, C.
    Blanchardon, E.
    Molokanov, A.
    Lechaftois, X.
    Broggio, D.
    Desbree, A.
    Franck, D.
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 220 - 226
  • [45] PRACTICAL NUCLEAR MEDICINE AND UTILITY OF PHANTOMS FOR INTERNAL DOSIMETRY: XCAT COMPARED WITH ZUBAL
    Fallahpoor, Maryam
    Abbasi, Mehrshad
    Kalantari, Faraz
    Parach, Ali Asghar
    Sen, Anando
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (02) : 191 - 197
  • [46] Effective and equivalent doses for CT head examinations calculated using the voxelized phantoms MASH and FASH
    Ferreira, C. C.
    Folly, W. S. D.
    Vieira, J. W.
    Maia, A. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (17): : 1867 - 1870
  • [47] Dosimetry calculations for internal electron sources using a Korean reference adult stylised phantom
    Park, S.
    Lee, J. K.
    Lee, C.
    Lee, C.
    RADIATION PROTECTION DOSIMETRY, 2008, 130 (02) : 186 - 205
  • [49] Breast dosimetry using high-resolution voxel phantoms
    Dance, DR
    Hunt, RA
    Bakic, PR
    Maidment, ADA
    Sandborg, M
    Ullman, G
    Carlsson, GA
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 359 - 363
  • [50] GATE simulations for small animal SPECT/PET using voxelized phantoms and rotating-head detectors
    Sakellios, Nikolas
    Rubio, Jose Luis
    Karakatsanis, Nicolas
    Kontaxakis, George
    Loudos, George
    Santos, Andres
    Nikita, Konstantina
    Majewski, Stan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2000 - 2003