The reliability and validity of the 30-seconds sit-to-stand test and its capacity for assessment of the functional status of hemodialysis patients

被引:12
|
作者
Figueiredo, Pedro Henrique Scheidt [1 ,2 ]
Veloso, Larissa Raphaela de Souza [1 ]
Lima, Marcia Maria Oliveira [1 ]
Vieira, Carlos Filipe Delmondes [2 ]
Alves, Frederico Lopes [3 ,4 ]
Lacerda, Ana Cristina Rodrigues [1 ,2 ]
Lima, Vanessa Pereira [1 ,2 ]
Rodrigues, Vanessa Gomes Brandao [2 ,3 ,4 ]
Maciel, Emilio Henrique Barroso [3 ,4 ]
Costa, Henrique Silveira [1 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Phys Therapy Sch, Diamantina, MG, Brazil
[2] Univ Fed Vales Jequitinhonha & Mucuri, Programa Posgrad Reabilitacao & Desempenho Func, Diamantina, MG, Brazil
[3] Santa Casa Caridade Diamantina Hosp, Hemodialysis Unit, Diamantina, MG, Brazil
[4] Univ Fed Vales Jequitinhonha & Mucuri, Sch Med, Diamantina, MG, Brazil
关键词
Exercise tolerance; Outcome assessment; Validity; Hemodialysis; 6-MINUTE WALK TEST; QUALITY-OF-LIFE; MAINTENANCE HEMODIALYSIS; PHYSICAL-ACTIVITY; REFERENCE VALUES; MUSCLE STRENGTH; PEOPLE; DISEASE; PERFORMANCE; MOBILITY;
D O I
10.1016/j.jbmt.2021.02.020
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the validity of the 30-seconds sit-to-stand test (STS-30) and its reliability in hemodialysis patients. Methods: Patients receiving hemodialysis treatment three times a week for at least six months were evaluated using STS-30, Incremental Shuttle Walking Test, and health-related quality of life by KDQOL-SF questionnaire. The data obtained from the Incremental Shuttle Walking Test were divided into tertiles, and the STS-30 results were compared among tertiles. The accuracy of the STS-30 to identify low exercise capacity was evaluated. A second STS-30 was performed after 6 to 8- weeks for the reliability analyses using Intraclass Correlation Coefficient (ICC). Minimal detectable change scores were calculated. Results: Sixty-three individuals (66.7% men) aged 48.3 years (95%CI 44.6-51.9) were evaluated. There were significant correlations between STS-30, exercise capacity (r = 0.72), and physical domains of health-related quality of life (0.30 <= r <= 0.51). Tertile 1 of the Incremental Shuttle Walking Test was different from tertiles 2 and 3 for STS-30 [difference of 3.4 repetitions (95%CI 1.5-5.4) and 4.7 repetitions (95%CI 2.8-6.7), respectively]. The value of 12 repetitions was the cut-off points for stratification of individuals with low exercise capacity. The STS-30 had a high test-retest reliability (ICC 0.93) and the minimal detectable change was 2.1 repetitions. Conclusion: The STS-30 is a reliable test, associated with exercise capacity and physical domains of health-related quality of life. Thus, is a valid method for functional evaluation in hemodialysis patients. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 50 条
  • [41] Validity of the 30-Second Sit-to-Stand test as a measure of lower extremity function in persons with multiple sclerosis: Preliminary evidence
    Zheng, Peixuan
    Huynh, Trinh L. T.
    Jones, C. Danielle
    Feasel, Corey D.
    Jeng, Brenda
    Motl, Robert W.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2023, 71
  • [42] Short- and long-term reliability of the 1-minute sit-to-stand test in patients with COPD
    Poncin, William
    Thu, Hang Nguyen Thi
    Le Khac, Bao
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [43] Use of sit-to-stand test to assess the physical capacity and exertional desaturation in patients post COVID-19
    Nunez-Cortes, Rodrigo
    Rivera-Lillo, Gonzalo
    Arias-Campoverde, Marisol
    Soto-Garcia, Dario
    Garcia-Palomera, Roberto
    Torres-Castro, Rodrigo
    CHRONIC RESPIRATORY DISEASE, 2021, 18
  • [44] Minimal clinically important difference in 30 second sit-to-stand test after pulmonary rehabilitation in patients with COPD
    Zanini, Andrea
    Crisafulli, Ernesto
    D'Andria, Michele
    Gregorini, Cristina
    Cherubino, Francesca
    Zampogna, Elisabetta
    Azzola, Andrea
    Spanevello, Antonio
    Chetta, Alfredo
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [45] Estimation of Functional Aerobic Capacity Using the Sit-to-Stand Test in Older Adults with Heart Failure with Preserved Ejection Fraction
    Jose Fuentes-Abolafio, Ivan
    Escriche-Escuder, Adrian
    Rosa Bernal-Lopez, Maria
    Gomez-Huelgas, Ricardo
    Ricci, Michele
    Trinidad-Fernandez, Manuel
    Roldan-Jimenez, Cristina
    Maria Arjona-Caballero, Jose
    Ignacio Cuesta-Vargas, Antonio
    Miguel Perez-Belmonte, Luis
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [46] Five-repetition sit-to-stand test in heart failure patients. Reliability and correlation with the Six Minutes Walking Test
    Maslowsky, F.
    Pribetich, M.
    Lo Bello, G.
    Milani, E.
    Braga, S. Sarzi
    Pedretti, R. F.
    EUROPEAN HEART JOURNAL, 2015, 36 : 634 - 634
  • [47] Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST)
    Kronberger, Christina
    Mousavi, Roya Anahita
    Oeztuek, Beguem
    Willixhofer, Robin
    Dachs, Theresa-Marie
    Rettl, Rene
    Camuz-Ligios, Luciana
    Rassoulpour, Nima
    Krall, Christoph
    Litschauer, Brigitte
    Badr Eslam, Roza
    PLOS ONE, 2023, 18 (03):
  • [48] In patients with chronic heart failure pulmonary artery enlargement is related to low functional capacity assessed with the one-minute sit-to-stand test
    Kronberger, C. Christina
    Willixhofer, R.
    Ermolaev, N.
    Rettl, R.
    Dachs, T. M.
    Ligios, L. Camuz
    Litschauer, B.
    Eslam, R. Badr
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 390 - 390
  • [49] Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST)
    Kronberger, Christina
    Mousavi, Roya Anahita
    oeztuerk, Beguem
    Willixhofer, Robin
    Dachs, Theresa-Marie
    Rettl, Rene
    Camuz-Ligios, Luciana
    Rassoulpour, Nima
    Krall, Christoph
    Litschauer, Brigitte
    Badr Eslam, Roza
    PLOS BIOLOGY, 2023, 21 (03)
  • [50] Determination of five times-sit-to-stand test performance in patients with multiple sclerosis: validity and reliability
    Ozudogru, Anil
    Canli, Mehmet
    Gurses, Omer Alperen
    Alkan, Halil
    Yetis, Aysu
    SOMATOSENSORY AND MOTOR RESEARCH, 2023, 40 (02): : 72 - 77