The reliability and validity of the 30-seconds sit-to-stand test and its capacity for assessment of the functional status of hemodialysis patients

被引:12
|
作者
Figueiredo, Pedro Henrique Scheidt [1 ,2 ]
Veloso, Larissa Raphaela de Souza [1 ]
Lima, Marcia Maria Oliveira [1 ]
Vieira, Carlos Filipe Delmondes [2 ]
Alves, Frederico Lopes [3 ,4 ]
Lacerda, Ana Cristina Rodrigues [1 ,2 ]
Lima, Vanessa Pereira [1 ,2 ]
Rodrigues, Vanessa Gomes Brandao [2 ,3 ,4 ]
Maciel, Emilio Henrique Barroso [3 ,4 ]
Costa, Henrique Silveira [1 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Phys Therapy Sch, Diamantina, MG, Brazil
[2] Univ Fed Vales Jequitinhonha & Mucuri, Programa Posgrad Reabilitacao & Desempenho Func, Diamantina, MG, Brazil
[3] Santa Casa Caridade Diamantina Hosp, Hemodialysis Unit, Diamantina, MG, Brazil
[4] Univ Fed Vales Jequitinhonha & Mucuri, Sch Med, Diamantina, MG, Brazil
关键词
Exercise tolerance; Outcome assessment; Validity; Hemodialysis; 6-MINUTE WALK TEST; QUALITY-OF-LIFE; MAINTENANCE HEMODIALYSIS; PHYSICAL-ACTIVITY; REFERENCE VALUES; MUSCLE STRENGTH; PEOPLE; DISEASE; PERFORMANCE; MOBILITY;
D O I
10.1016/j.jbmt.2021.02.020
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the validity of the 30-seconds sit-to-stand test (STS-30) and its reliability in hemodialysis patients. Methods: Patients receiving hemodialysis treatment three times a week for at least six months were evaluated using STS-30, Incremental Shuttle Walking Test, and health-related quality of life by KDQOL-SF questionnaire. The data obtained from the Incremental Shuttle Walking Test were divided into tertiles, and the STS-30 results were compared among tertiles. The accuracy of the STS-30 to identify low exercise capacity was evaluated. A second STS-30 was performed after 6 to 8- weeks for the reliability analyses using Intraclass Correlation Coefficient (ICC). Minimal detectable change scores were calculated. Results: Sixty-three individuals (66.7% men) aged 48.3 years (95%CI 44.6-51.9) were evaluated. There were significant correlations between STS-30, exercise capacity (r = 0.72), and physical domains of health-related quality of life (0.30 <= r <= 0.51). Tertile 1 of the Incremental Shuttle Walking Test was different from tertiles 2 and 3 for STS-30 [difference of 3.4 repetitions (95%CI 1.5-5.4) and 4.7 repetitions (95%CI 2.8-6.7), respectively]. The value of 12 repetitions was the cut-off points for stratification of individuals with low exercise capacity. The STS-30 had a high test-retest reliability (ICC 0.93) and the minimal detectable change was 2.1 repetitions. Conclusion: The STS-30 is a reliable test, associated with exercise capacity and physical domains of health-related quality of life. Thus, is a valid method for functional evaluation in hemodialysis patients. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 50 条
  • [21] Assessment of Validity and Reliability of the 1-Minute Sit-to-Stand Test to Measure the Heart Rate Response to Exercise in Healthy Children
    Reychler, Gregory
    Audag, Nicolas
    Mestre, Natalia Morales
    Caty, Gilles
    JAMA PEDIATRICS, 2019, 173 (07) : 692 - 693
  • [22] The one-minute sit-to-stand test: A novel tool for assessing functional capacity in patients with atrial fibrillation
    Kutukcu, Ebru Calik
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2025, 421
  • [23] A study of the reliability and construct validity of the 1-minute sit-to-stand test for individuals with systemic sclerosis
    Laursen, Jakob
    Christensen, Amalie
    Egsgaard, Simon
    Sondergaard, Klaus
    Mechlenburg, Inger
    Brincks, John
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024,
  • [24] Assessment of the 4-meter walk test test-retest reliability and concurrent validity and its correlation with the five sit-to-stand test in chronic ambulatory stroke survivors
    Cabanas-Valdes, Rosa
    Garcia-Rueda, Laura
    Salgueiro, Carina
    Perez-Bellmunt, Albert
    Rodriguez-Sanz, Jacobo
    Lopez-de-Cells, Carlos
    GAIT & POSTURE, 2023, 101 : 8 - 13
  • [25] Reliability of remote 1-minute sit-to-stand test to measure physical capacity in patients with chronic respiratory diseases
    Larrateguy, Santiago
    Otto-Yanes, Matias
    Bogado, Juan
    Larrateguy, Luis
    Blanco, Isabel
    Gimeno-Santos, Elena
    Torres-Castro, Rodrigo
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [26] The five times sit-to-stand test: safety, validity and reliability with critical care survivors’s at ICU discharge
    Thiago Araújo de Melo
    Fernando Silva Guimarães
    José Roberto Lapa e Silva
    Archives of Physiotherapy, 13
  • [27] The five times sit-to-stand test: safety, validity and reliability with critical care survivors's at ICU discharge
    de Melo, Thiago Araujo
    Silva Guimaraes, Fernando
    Lapa e Silva, Jose Roberto
    ARCHIVES OF PHYSIOTHERAPY, 2022, 13 (01)
  • [28] Validity, reliability, and measurement error of a sit-to-stand power test in older adults: A pre-registered study
    Balachandran, Anoop T.
    Vigotsky, Andrew D.
    Quiles, Norberto
    Mokkink, Lidwine B.
    Belio, Mark A.
    Glenn, Jordan McKenzie
    EXPERIMENTAL GERONTOLOGY, 2021, 145
  • [29] ACCELEROMETRIC ASSESSMENT OF PHYSICAL PERFORMANCE DURING THE SIT-TO-STAND TEST IN PATIENTS WITH KNEE OSTEOARTHRITIS
    Fellous, S.
    Rkain, H.
    Afilal, S.
    Moulay Berkchi, J.
    Fatima Zahrae, T.
    Ilham, A.
    Latifa, T.
    Aboudrar, S.
    Dakka, T.
    Errguig, L.
    Jniene, A.
    Bakkali, M.
    Allali, F.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 1929 - 1929
  • [30] Clinical Significance of 30-Second Sit-to-Stand Test in Patients with Idiopathic Pulmonary Fibrosis
    Harputlu, Ozge Ertan
    Akinci, Buket
    Aslan, Goksen Kuran
    Arslan, Melike Saritas
    Okumus, Gulfer
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64