Specific, simple and rapid detection of porcine circovirus type 2 using the loop-mediated isothermal amplification method

被引:25
|
作者
Zhao, Kai [1 ,3 ]
Shi, Wei [4 ]
Han, Fangting [4 ]
Xu, Yan [4 ]
Zhu, Lianlong [1 ,3 ]
Zou, Yong [2 ,3 ]
Wu, Xiao [1 ,3 ]
Zhu, Hong [1 ,3 ]
Tan, Furong [1 ,3 ]
Tao, Shiru [1 ,3 ]
Tang, Xueming [1 ,3 ]
机构
[1] Shanghai Acad Agr Sci, Biotechnol Res Inst, Shanghai 201106, Peoples R China
[2] Shanghai Acad Agr Sci, Inst Anim Sci & Vet Med, Shanghai 201106, Peoples R China
[3] Shanghai Acad Agr Sci, Key Lab Agr Genet & Breeding, Shanghai 201106, Peoples R China
[4] Shanghai Normal Univ, Coll Life & Environm Sci, Shanghai 200234, Peoples R China
关键词
MULTISYSTEMIC WASTING SYNDROME; REAL-TIME PCR; VIRUS; QUANTITATION; DNA; H5;
D O I
10.1186/1743-422X-8-126
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Porcine circovirus type 2 (PCV2) is the causative agent of postweaning multisystemic wasting syndrome (PMWS), and porcine dermatitis and nephropathy syndrome (PDNS). It has caused heavy losses in global agriculture in recent decades. Rapid detection of PCV2 is very important for the effective prophylaxis and treatment of PMWS. Results: A loop-mediated isothermal amplification (LAMP) assay was used to detect PCV2 in this study. Three pairs of primers were specially designed for recognizing eight distinct sequences of the ORF2 gene. This gene lies in the PCV2 virus genome sequence, and encodes the Rep protein that is involved in virus replication. Time and temperature conditions for amplification of PCV2 genes were optimized to be 55 min at 59 degrees C. The analysis of clinical samples indicated that the LAMP method was highly sensitive. The detection limit for PCV2 by the LAMP assay was 10 copies, whereas the limit by conventional PCR was 1000 copies. The assay did not cross-react with PCV1, porcine reproductive and respiratory syndrome virus, porcine epidemic diarrhea virus, transmissible gastroenteritis of pigs virus or rotavirus. When 110 samples were tested using the established LAMP system, 95 were detected as positive. Conclusion: The newly developed LAMP detection method for PCV2 was more specific, sensitive, rapid and simple than before. It complements and extends previous methods for PCV2 detection and provides an alternative approach for detection of PCV2.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Simple and rapid method for the detection of Filobasidiella neoformans in a probiotic dairy product by using loop-mediated isothermal amplification
    Ishikawa, Hiroshi
    Kasahara, Kohei
    Sato, Sumie
    Shimakawa, Yasuhisa
    Watanabe, Koichi
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2014, 178 : 107 - 112
  • [42] Sensitive and rapid detection of Trueperella pyogenes using loop-mediated isothermal amplification method
    Zhang, Wenlong
    Meng, Xiangli
    Wang, Junwei
    JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 93 (02) : 124 - 126
  • [43] Visual and rapid detection of Plesiomonas shigelloides using loop-mediated isothermal amplification method
    Liu, H.
    Yu, H.
    Peng, Z. Q.
    Yu, Y. Y.
    Xie, J. F.
    Yang, Y.
    LETTERS IN APPLIED MICROBIOLOGY, 2019, 69 (06) : 411 - 416
  • [44] Simple Detection of Hepatitis B Virus in Using Loop-Mediated Isothermal Amplification Method
    Chen, Hua-Wei
    Belinskaya, Tatyana
    Zhang, Zhiwen
    Ching, Wei-Mei
    MILITARY MEDICINE, 2019, 184 (7-8) : E275 - E280
  • [45] Rapid Visual Detection of Getah Virus Using a Loop-Mediated Isothermal Amplification Method
    Liu, Hao
    Li, Li-Xia
    Bu, Ya-Ping
    Liu, Yu
    Sun, Xiu-Tao
    Shi, Ning
    Deng, Xiao-Yu
    Lu, Rong-Guang
    Hu, Bo
    Jin, Ning-Yi
    Yan, Xi-Jun
    VECTOR-BORNE AND ZOONOTIC DISEASES, 2019, 19 (10) : 741 - 746
  • [46] Rapid Detection of Streptococcus agalactiae Infection Using a Loop-Mediated Isothermal Amplification Method
    Yang, Weihua
    Cao, Cuiming
    Wang, Weichen
    Wang, Yunshan
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2016, 9 (12) : 1 - 6
  • [47] SIMPLE AND RAPID METHOD FOR DETECTING FOODBORNE SHIGELLA BY A LOOP-MEDIATED ISOTHERMAL AMPLIFICATION
    Li, Sulong
    Zhang, Xinbo
    Wang, Deguo
    Kuang, Yanyun
    Xu, Yigang
    JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2009, 17 (04): : 465 - 475
  • [48] Development of a real-time loop-mediated isothermal amplification assay for detection of porcine circovirus 3
    Wang, Huanan
    Liu, Xiangnan
    Zeng, Fanwen
    Zhang, Tongyuan
    Lian, Yuexiao
    Wu, Miaoli
    Xiao, Li
    Zhu, Yujun
    Zhang, Yu
    Chen, Meili
    Huang, Ren
    Luo, Manlin
    Cong, Feng
    Guo, Pengju
    BMC VETERINARY RESEARCH, 2019, 15 (01)
  • [49] Development of a rapid cyprinid herpesvirus 2 detection method by loop-mediated isothermal amplification
    Liang, L. -G.
    Xie, J.
    Luo, D.
    LETTERS IN APPLIED MICROBIOLOGY, 2014, 59 (04) : 432 - 437
  • [50] Development of a real-time loop-mediated isothermal amplification assay for detection of porcine circovirus 3
    Huanan Wang
    Xiangnan Liu
    Fanwen Zeng
    Tongyuan Zhang
    Yuexiao Lian
    Miaoli Wu
    Li Xiao
    Yujun Zhu
    Yu Zhang
    Meili Chen
    Ren Huang
    Manlin Luo
    Feng Cong
    Pengju Guo
    BMC Veterinary Research, 15