Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT

被引:7
|
作者
Wallace, Adam N. [1 ,2 ]
Vyhmeister, Ross [2 ]
Bagade, Swapnil [1 ,2 ]
Chatterjee, Arindam [1 ,2 ]
Hicks, Brandon [1 ,2 ]
Ramirez-Giraldo, Juan Carlos [3 ]
McKinstry, Robert C. [1 ,2 ]
机构
[1] Barnes Jewish Hosp, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, St Louis, MO 63110 USA
[3] Siemens Healthcare, Malvern, PA USA
关键词
Head CT; Cerebrospinal fluid shunt; Automatic tube current modulation; Automatic tube potential selection; CareDose4D; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; TREATED HYDROCEPHALUS; COMPUTED-TOMOGRAPHY; RADIATION; REDUCTION; CHILDREN; SCANNER; CANCER; RISKS;
D O I
10.1007/s00234-015-1508-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [1] Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT
    Adam N. Wallace
    Ross Vyhmeister
    Swapnil Bagade
    Arindam Chatterjee
    Brandon Hicks
    Juan Carlos Ramirez-Giraldo
    Robert C. McKinstry
    Neuroradiology, 2015, 57 : 639 - 644
  • [2] Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams
    Park, M.
    Rosica, D.
    Agarwal, V.
    Di Carli, M.
    Dorbala, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3393 - 3394
  • [3] Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?
    Hyun Kyong Lim
    Kyoung Ho Lee
    So Yeon Kim
    Kil Joong Kim
    Bohyoung Kim
    Hyunna Lee
    Seong Ho Park
    Jeffrey H. Yanof
    Seung-sik Hwang
    Young Hoon Kim
    European Radiology, 2011, 21 : 345 - 352
  • [4] Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?
    Lim, Hyun Kyong
    Lee, Kyoung Ho
    Kim, So Yeon
    Kim, Kil Joong
    Kim, Bohyoung
    Lee, Hyunna
    Park, Seong Ho
    Yanof, Jeffrey H.
    Hwang, Seung-sik
    Kim, Young Hoon
    EUROPEAN RADIOLOGY, 2011, 21 (02) : 345 - 352
  • [5] Low-dose CT screening for lung cancer with automatic exposure control: phantom study.
    Gomi S.
    Muramatsu Y.
    Tsukagoshi S.
    Suzuki M.
    Kakinuma R.
    Tsuchiya R.
    Moriyama N.
    Radiological Physics and Technology, 2008, 1 (2) : 244 - 250
  • [6] Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
    Yu, Lifeng
    Li, Hua
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2010, 37 (01) : 234 - 243
  • [7] Potential for Radiation Dose Savings in Abdominal and Chest CT Using Automatic Tube Voltage Selection in Combination With Automatic Tube Current Modulation
    Mayer, Caroline
    Meyer, Mathias
    Fink, Christian
    Schmidt, Bernhard
    Sedlmair, Martin
    Schoenberg, Stefan O.
    Henzler, Thomas
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 292 - 299
  • [8] Automatic Tube Potential Selection for Radiation Dose Reduction in Abdominal CT: Techniques and Experimental Study
    Yu, L.
    Li, H.
    Fletcher, J.
    McCollough, C.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Automatic Exposure Control techniques in low dose CT - what benefit in PET/CT studies?
    Ferreira, R.
    Sousa, V.
    Victor, M. R.
    Carmona, S.
    Cardoso, G.
    Santos, A. I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S79 - S80
  • [10] Automatic segmentation of mandibles in low-dose CT-data
    Lamecker, H.
    Zachow, S.
    Wittmers, Antonia
    Weber, Britta
    Hege, H. -C.
    Isholtz, B.
    Stiller, M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 393 - 395