Comparative extraction of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F-s) from a variety of solid samples

被引:0
|
作者
Wu, WZ [1 ]
Schramm, KW [1 ]
Henkelmann, B [1 ]
Xu, Y [1 ]
Zhang, YY [1 ]
Kettrup, A [1 ]
机构
[1] GSF FORSCHUNGSZENTRUM UMWELT & GESUNDHEIT,INST OKOL CHEM,D-85764 OBERSCHLEISSHEIM,GERMANY
关键词
PCDD/F-s; extraction; recovery;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Extraction experiments with spiking of C-13(12)-PCDD/Fs were performed with a variety of PCDD/Fs contaminated samples. The extraction recovery of PCDD/Fs was mainly influenced by PCDD/Fs concentration and the sample matrix. Generally, the first soxhlet extraction with toluene has suitable recovery. From the selected samples, only FAMS4 and 5 which are fly ashes with high concentration, the recovery of the first soxhlet extraction with 24 hr. is low, but PCDD/Fs were almost completely removed after 72 hr. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:2229 / 2237
页数:9
相关论文
共 50 条
  • [21] Addition of surrogate standards in the routine analysis of investigating polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F)
    Lars-Owe Kjeller
    Environmental Science and Pollution Research, 1998, 5 : 198 - 198
  • [22] METHODOLOGY FOR THE DETERMINATION OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN SEDIMENT SAMPLES
    KJELLER, LO
    KULP, SE
    JONSSON, B
    RAPPE, C
    TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 1993, 39 (1-2): : 1 - 12
  • [23] Atmospheric deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in Guangzhou, China
    Ren, Man
    Peng, Ping'an
    Zhang, Sukun
    Yu, Liping
    Zhang, Gan
    Mai, Bixian
    Sheng, Guoying
    Fu, Jiamo
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (03) : 592 - 605
  • [24] Determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in Brazilian cow milk
    Rocha, Dayse A. M.
    Torres, Joao P. M.
    Reichel, Klaus
    Novotny, Etelvino H.
    Estrella, Leonardo F.
    Medeiros, Rebeca O.
    Pereira Netto, Annibal D.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 572 : 177 - 184
  • [25] Dry deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient air
    Shih, ML
    Lee, WS
    Chang-Chien, GP
    Wang, LC
    Hung, CY
    Lin, KC
    CHEMOSPHERE, 2006, 62 (03) : 411 - 416
  • [26] DIRECT ELUTION OF SOLID-PHASE EXTRACTION DISKS FOR THE DETERMINATION OF POLYCHLORINATED DIBENZO-P-DIOXINS AND POLYCHLORINATED DIBENZOFURANS IN EFFLUENT SAMPLES
    TAYLOR, KZ
    WADDELL, DS
    REINER, EJ
    MACPHERSON, KA
    ANALYTICAL CHEMISTRY, 1995, 67 (07) : 1186 - 1190
  • [27] Thermodynamic prediction of vapor pressures for polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and polybrominated dibenzo-p-dioxins
    Li, XW
    Shibata, E
    Nakamura, T
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2005, 24 (09) : 2167 - 2177
  • [28] Results of an initial survey of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in textiles
    Horstmann, M.
    McLachlan, M.S.
    Chemosphere, 1995, 31 (02):
  • [29] DETERMINATION OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN SAMPLES OF SOIL AND OTHER SOLID ENVIRONMENTAL MATERIAL
    GOTZ, R
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 314 (02): : 133 - 134