Accuracy evaluation of on-wafer load-pull measurements

被引:26
|
作者
Ferrero, A [1 ]
Teppati, V [1 ]
Carullo, A [1 ]
机构
[1] Politecn Torino, Dipartimento Elettron, I-10129 Turin, Italy
关键词
accuracy; load-pull; microwave measurements;
D O I
10.1109/22.899960
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the residual calibration uncertainty effects in on-wafer load-pull measurements. After the systematic error correction (based on a traditional error-box model) has been applied, the residual uncertainty on absolute-power-level measurements can dramatically affect the accuracy of typical nonlinear parameters such as gain and power-added efficiency under different load conditions. The main residual uncertainty contributions are highlighted both by a theoretical analysis and experiments, Finally, one of the possible causes for intermodulation-distortion measurement errors is shown.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 50 条
  • [31] LOAD-PULL MEASUREMENTS HELP YOU MEET YOUR MATCH
    POULIN, D
    MICROWAVES, 1980, 19 (12): : 61 - &
  • [32] Behavioral Model Analysis of Active Harmonic Load-pull Measurements
    Woodington, S.
    Saini, R.
    Williams, D.
    Lees, J.
    Benedikt, J.
    Tasker, P. J.
    2010 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (MTT), 2010, : 1688 - 1691
  • [33] An improved coupling method for time domain Load-Pull measurements
    De Groote, Fabien
    Verspecht, Jan
    Barataud, Denis
    Teyssier, Jean-Pierre
    35th European Microwave Conference, Vols 1-3, Conference Proceedings, 2005, : 601 - 604
  • [34] Harmonic Load-Pull Techniques
    Ferrero, Andrea
    Pirola, Marco
    IEEE MICROWAVE MAGAZINE, 2013, 14 (04) : 116 - 123
  • [35] Highly Reflective Load-Pull
    Hashmi, Mohammad S.
    Ghannouchi, Fadhel M.
    Tasker, Paul J.
    Rawat, Karun
    IEEE MICROWAVE MAGAZINE, 2011, 12 (04) : 96 - 107
  • [36] SOURCE-PULL LOAD-PULL OSCILLATOR MEASUREMENTS AT MICROWAVE MM WAVE FREQUENCIES
    GHANNOUCHI, FM
    BOSISIO, RG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (01) : 32 - 35
  • [37] Further Improvements in Real-Time Load-Pull Measurement Accuracy
    Bonino, Serena
    Teppati, Valeria
    Ferrero, Andrea
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2010, 20 (02) : 121 - 123
  • [38] Evaluation and Reduction of Calibration Residual Uncertainty in Load-Pull Measurements at Millimeter-Wave Frequencies
    Teppati, Valeria
    Bolognesi, C. R.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (03) : 817 - 822
  • [39] Improving accuracy and reliability of microwave on-wafer silicon device measurements
    Kolding, TE
    MICROWAVE JOURNAL, 2000, 43 (11) : 22 - +
  • [40] LOAD-PULL ANALYSIS .1. ALGORITHM PROVIDES EFFICIENT FET LOAD-PULL ANALYSIS
    ROBERTS, JT