Accuracy evaluation of on-wafer load-pull measurements

被引:26
|
作者
Ferrero, A [1 ]
Teppati, V [1 ]
Carullo, A [1 ]
机构
[1] Politecn Torino, Dipartimento Elettron, I-10129 Turin, Italy
关键词
accuracy; load-pull; microwave measurements;
D O I
10.1109/22.899960
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the residual calibration uncertainty effects in on-wafer load-pull measurements. After the systematic error correction (based on a traditional error-box model) has been applied, the residual uncertainty on absolute-power-level measurements can dramatically affect the accuracy of typical nonlinear parameters such as gain and power-added efficiency under different load conditions. The main residual uncertainty contributions are highlighted both by a theoretical analysis and experiments, Finally, one of the possible causes for intermodulation-distortion measurement errors is shown.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 50 条
  • [21] On the load-pull effect in MMIC oscillator measurements
    Schott, M
    Lenk, F
    Heymann, P
    33RD EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2003, : 367 - 370
  • [22] Load-pull measurements using modulated signals
    Noori, B.
    Hart, P.
    Wood, J.
    Aaen, P. H.
    Gtryonnet, M.
    Lefevre, M.
    Pla, J. A.
    Jones, J.
    2006 EUROPEAN MICROWAVE CONFERENCE, VOLS 1-4, 2006, : 1557 - +
  • [23] ACCURACY ISSUES OF ON-WAFER MICROWAVE NOISE MEASUREMENTS
    Chen, Chih-Hung
    FLUCTUATION AND NOISE LETTERS, 2008, 8 (3-4): : L281 - L303
  • [24] New trends for multiharmonic source-pull and load-pull measurements
    Leloir, S
    Fouquet, F
    Tolant, C
    Eudeline, P
    Mazari, B
    34TH EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2004, : 681 - 684
  • [25] On-Wafer, Large-Signal Transistor Characterization from 70-110 GHz Using an Optimized Load-Pull Technique
    Zhang, Jason
    Urbonas, Jonas
    Esposito, Giampiero
    Arias-Purdue, Andrea
    Rowell, Petra
    MICROWAVE JOURNAL, 2021, 64 (02) : 82 - 90
  • [26] Source/Load-Pull Noise Measurements at Ka Band
    Colangeli, Sergio
    Ciccognani, Walter
    Longhi, Patrick Ettore
    Pace, Lorenzo
    Serino, Antonio
    Poulain, Julien
    Leblanc, Remy
    Limiti, Ernesto
    ENERGIES, 2021, 14 (18)
  • [27] Load-Pull Measurements using Centroidal Voronoi Tessellation
    Barmuta, Pawel
    Lukasik, Konstanty
    Ferranti, Francesco
    Gibiino, Gian Piero
    Lewandowski, Arkadiusz
    Schreurs, Dominique
    2017 89TH ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG): ADVANCED TECHNOLOGIES FOR COMMUNICATIONS, 2017,
  • [28] Source-pull and multiharmonic load-pull measurements based on sixport techniques
    Berghoff, G
    Gibrat, O
    Bergeault, E
    Huyart, B
    Jallet, L
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 492 - 493
  • [29] A HIGH-POWER ON-WAFER PULSED ACTIVE LOAD PULL SYSTEM
    POULIN, DD
    MAHON, JR
    LANTERI, JP
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1992, 40 (12) : 2412 - 2417
  • [30] Concurrent Surrogate Modeling and Adaptive Sampling in Load-Pull Measurements
    Barmuta, Pawel
    Ferranti, Francesco
    Lukasik, Konstanty
    Lewandowski, Arkadiusz
    Schreurs, Dominique
    2015 INTEGRATED NONLINEAR MICROWAVE AND MILLIMETRE-WAVE CIRCUITS WORKSHOP (INMMIC), 2015,