The efficiency of cutting balloon angioplasty in the treatment of in-stent restenosis

被引:0
|
作者
Ates, Haci [1 ]
Duygu, Hamza [1 ]
Cakir, Cayan [1 ]
Acet, Halit [1 ]
Akdemir, Sefa [1 ]
Akyildiz, Zehra Ilke [1 ]
Kocabas, Ugur [1 ]
Nazli, Cem [1 ]
Ergene, Oktay [1 ]
机构
[1] Ataturk Egitim & Arastirma Hastanesi, Kardiyol Klin, Izmir, Turkey
来源
ANATOLIAN JOURNAL OF CARDIOLOGY | 2011年 / 11卷 / 05期
关键词
Restenosis; cutting balloon angioplasty;
D O I
10.5152/akd.2011.111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although stents reduce the restenosis rate, stent restenosis continues to be a major problem and the optimal treatment of stent restenosis is still controversial. In this study, we aimed to investigate the angiographic recurrent stent restenosis rate at 6-12 months after successful cutting balloon angioplasty (CBA) for the bare metal stent restenosis. Methods: Thirty patients (mean age: 57.9 +/- 11.6, 22 males) undergoing successful CBA for the treatment of in-stent restenosis at our hospital were prospectively included in this study. Control coronary angiography was performed at 6-12 months after CBA. Lesion length, minimal lumen diameter (MLD), and reference vessel diameter were analyzed by computerized digital angiographic analysis. Recurrent restenosis was defined as the lesions obstructing the lumen more than 50%. We described the lesions shorter than 10 mm as to be focal and those longer than 10 mm as to be diffuse. We used Student t, Chi-square, and Mann-Whitney U tests for statistical analysis. Results: Two patients had two distinct lesions; therefore, 32 lesions were assessed. There were 9 (28.1%) recurrent restenosis on the control coronary angiography. Recurrent restenosis developed in 3/21 (14.3%) of focal type lesions and 6/11(54.5%) of diffuse type lesions (p=0.035). Pre-procedural MLD was lower in the restenotic group compared to non-restenotic group (0.41 +/- 0.29 vs. 0.64 +/- 0.17 mm, p=0.048) while percent of stenosis was higher in the restenotic group (76.8 +/- 12 vs. 69.6 +/- 5.37%, p=0.029). Conclusion: In the selected patients, CBA is an effective and a safe method for the treatment of bare metal stent restenosis. CBA might be considered as a first-line treatment method in patients with focal type lesions. (Anadolu Kardiyol Derg 2011; 11: 436-40)
引用
收藏
页码:436 / 440
页数:5
相关论文
共 50 条
  • [11] Cutting balloon angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis: Multicenter in-stent restenosis registry in Japan
    Nakamura, S
    Hirose, M
    Saito, E
    Miyauchi, T
    Kanazawa, A
    Hozawa, K
    Nakamura, H
    Yamamoto, K
    Makishima, N
    Nakamura, S
    Koyama, J
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 174L - 175L
  • [12] Cutting balloon angioplasty versus rotablator atherectomy for treatment of diffuse in-stent restenosis
    Nakamura, S
    Yokoyama, J
    Kudou, T
    Kanazawa, A
    Matsukawa, S
    Oohira, H
    Nakamura, S
    Houzawa, K
    Koyama, J
    Hayama, Y
    CIRCULATION, 2001, 104 (17) : 509 - 509
  • [13] Comparison of the efficacy of cutting balloon angioplasty and balloon angioplasty for high risk in-stent restenosis
    Iijima, R
    Nakamura, M
    Matuda, K
    Suzuki, T
    Takagi, T
    Tsunoda, T
    Yamaguchi, T
    EUROPEAN HEART JOURNAL, 2000, 21 : 394 - 394
  • [14] Diffuse in-stent restenosis: Outcomes of cutting balloon angioplasty vs. balloon angioplasty
    Spanos, V
    Moshiri, S
    Sarais, C
    Montorfano, M
    Airoldi, F
    Maccagni, D
    Liistro, F
    Tucci, G
    Ferraro, M
    Albiero, R
    CIRCULATION, 2002, 106 (19) : 481 - 481
  • [15] Cutting balloon angioplasty for resistant renal artery in-stent restenosis
    Munneke, GJ
    Engelke, C
    Morgan, RA
    Belli, AM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (03) : 327 - 331
  • [16] Cutting balloon angioplasty followed by gamma radiation for in-stent restenosis
    Kobayashi, Y
    Balan, O
    Arif, F
    Adamian, Y
    Mohamed, M
    Collins, M
    Kreps, E
    CIRCULATION, 2001, 104 (17) : 416 - 416
  • [17] Cutting balloon angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis: multicentre diffuse in-stent restenosis registry in Japan
    Nakamura, S
    Hirose, M
    Miyauchi, T
    Kanazawa, A
    Hozawa, K
    Makishima, N
    Nakamura, S
    Koyama, J
    EUROPEAN HEART JOURNAL, 2004, 25 : 310 - 310
  • [18] Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis
    Mehran, R
    Mintz, GS
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06): : 618 - 622
  • [19] Cutting balloon for treatment of in-stent restenosis: A matched comparison with conventional angioplasty and rotational atherectomy
    Adamian, MG
    Marsico, F
    Briguori, C
    Yamashita, T
    De Gregorio, J
    Corvaja, N
    Vaghetti, M
    Albiero, R
    Di Mario, C
    Colombo, A
    CIRCULATION, 1999, 100 (18) : 305 - 305
  • [20] Colchicine Reduces Restenosis after Balloon Angioplasty Treatment for In-Stent Restenosis
    Kong, Junying
    Deng, Ying
    Dong, Qiang
    Liu, Wenhua
    Lu, Ying
    ARCHIVES OF MEDICAL RESEARCH, 2015, 46 (02) : 101 - 106