The efficiency of cutting balloon angioplasty in the treatment of in-stent restenosis

被引:0
|
作者
Ates, Haci [1 ]
Duygu, Hamza [1 ]
Cakir, Cayan [1 ]
Acet, Halit [1 ]
Akdemir, Sefa [1 ]
Akyildiz, Zehra Ilke [1 ]
Kocabas, Ugur [1 ]
Nazli, Cem [1 ]
Ergene, Oktay [1 ]
机构
[1] Ataturk Egitim & Arastirma Hastanesi, Kardiyol Klin, Izmir, Turkey
来源
ANATOLIAN JOURNAL OF CARDIOLOGY | 2011年 / 11卷 / 05期
关键词
Restenosis; cutting balloon angioplasty;
D O I
10.5152/akd.2011.111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although stents reduce the restenosis rate, stent restenosis continues to be a major problem and the optimal treatment of stent restenosis is still controversial. In this study, we aimed to investigate the angiographic recurrent stent restenosis rate at 6-12 months after successful cutting balloon angioplasty (CBA) for the bare metal stent restenosis. Methods: Thirty patients (mean age: 57.9 +/- 11.6, 22 males) undergoing successful CBA for the treatment of in-stent restenosis at our hospital were prospectively included in this study. Control coronary angiography was performed at 6-12 months after CBA. Lesion length, minimal lumen diameter (MLD), and reference vessel diameter were analyzed by computerized digital angiographic analysis. Recurrent restenosis was defined as the lesions obstructing the lumen more than 50%. We described the lesions shorter than 10 mm as to be focal and those longer than 10 mm as to be diffuse. We used Student t, Chi-square, and Mann-Whitney U tests for statistical analysis. Results: Two patients had two distinct lesions; therefore, 32 lesions were assessed. There were 9 (28.1%) recurrent restenosis on the control coronary angiography. Recurrent restenosis developed in 3/21 (14.3%) of focal type lesions and 6/11(54.5%) of diffuse type lesions (p=0.035). Pre-procedural MLD was lower in the restenotic group compared to non-restenotic group (0.41 +/- 0.29 vs. 0.64 +/- 0.17 mm, p=0.048) while percent of stenosis was higher in the restenotic group (76.8 +/- 12 vs. 69.6 +/- 5.37%, p=0.029). Conclusion: In the selected patients, CBA is an effective and a safe method for the treatment of bare metal stent restenosis. CBA might be considered as a first-line treatment method in patients with focal type lesions. (Anadolu Kardiyol Derg 2011; 11: 436-40)
引用
收藏
页码:436 / 440
页数:5
相关论文
共 50 条
  • [1] Cutting balloon angioplasty for treatment of in-stent restenosis
    Lauer, B
    Schmidt, B
    Stellbring, S
    Ambrosch, H
    Boudriot, E
    Diederich, K
    Hambrecht, R
    Krankenberg, H
    Sick, P
    Zotz, R
    Schuler, G
    CIRCULATION, 2000, 102 (18) : 365 - 365
  • [2] Cutting Balloon angioplasty for the treatment of in-stent restenosis
    Albiero, R
    Nishida, T
    Karvouni, E
    Corvaja, N
    Vaghetti, M
    Di Mario, C
    Colombo, A
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (04) : 452 - 459
  • [3] Cutting Balloon angioplasty for in-stent restenosis
    Kurbaan, AS
    Foale, RA
    Sigwart, U
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (04) : 480 - 483
  • [4] Cutting balloon angioplasty for in-stent restenosis.
    Stankovic, G
    Albiero, R
    Di Mario, C
    Corvaja, N
    Nishida, T
    Vaghetti, M
    Sivieri, G
    Colombo, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (8A): : 24I - 24I
  • [5] Cutting balloon angioplasty versus balloon angioplasty for treating diffuse in-stent restenosis
    Spanos, V
    Sarais, C
    Toutouzas, K
    Moshiri, S
    Montorfano, M
    Briguori, C
    Stankovic, G
    Colombo, A
    EUROPEAN HEART JOURNAL, 2002, 23 : 553 - 553
  • [6] Cutting Balloon Combined with Drug-Coated Balloon Angioplasty for the Treatment of In-Stent Restenosis
    Zheng, You-Cheng
    Lee, Wei-Chieh
    Fang, Hsiu-Yu
    Chen, Chien-Jen
    Yang, Cheng-Hsu
    Wu, Chiung-Jen
    Fang, Chih-Yuan
    INTERNATIONAL HEART JOURNAL, 2021, 62 (06) : 1213 - 1220
  • [7] Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis - Results of the Restenosis Cutting Balloon Evaluation Trial (RESCUT)
    Albiero, R
    Silber, S
    Di Mario, C
    Cernigliaro, C
    Battaglia, S
    Reimers, B
    Frasheri, A
    Klauss, V
    Auge, JM
    Rubartelli, P
    Morice, MC
    Cremonesi, A
    Schofer, J
    Bortone, A
    Colombo, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (06) : 943 - 949
  • [8] The impact of Cutting Balloon Angioplasty for the treatment of diffuse In-Stent Restenosis. Comparison with conventional balloon angioplasty
    Iijima, R
    Nakamura, M
    Kitagawa, Y
    Nakajima, R
    Yoshitama, T
    Takagi, T
    Anzai, H
    Tunoda, T
    Yamaguchi, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 80A - 80A
  • [9] Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty
    Adamian, M
    Colombo, A
    Briguori, C
    Nishida, T
    Marsico, F
    Di Mario, C
    Albiero, R
    Moussa, I
    Moses, JW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) : 672 - 679
  • [10] Intracoronary β-radiation combined with cutting balloon angioplasty for treatment of in-stent restenosis.
    Zhou, Y
    Qu, D
    Liu, W
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (8A): : 17A - 17A