Innovative phase shifter for pulse tube operating below 10 K

被引:1
|
作者
Duval, Jean-Marc [1 ,2 ]
Charles, Ivan [1 ,2 ]
Daniel, Christophe [3 ]
Andre, Jerome [1 ,2 ]
机构
[1] Univ Grenoble Alpes, INAC SBT, F-38000 Grenoble, France
[2] CEA, INAC SBT, F-38000 Grenoble, France
[3] CNES, 18 Ave Edouard Belin, F-31401 Toulouse 9, France
关键词
Cryocooler; Pulse tube; Diaphragm; Inertance tube;
D O I
10.1016/j.cryogenics.2016.07.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
Stirling type pulse tubes are classically based on the use of an inertance phase shifter to optimize their cooling power. The limitations of the phase shifting capabilities of these inertances have been pointed out in various studies. These limitations are particularly critical for low temperature operation, typically below about 50 K. An innovative phase shifter using an inertance tube filled with liquid, or fluid with high density or low viscosity, and separated by a sealed metallic diaphragm has been conceived and tested. This device has been characterized and validated on a dedicated test bench. Operation on a 50-80 K pulse tube cooler and on a low temperature (below 8 K) pulse tube cooler have been demonstrated and have validated the device in operation. These developments open the door for efficient and compact low temperature Stirling type pulse tube coolers. The possibility of long life operation has been experimentally verified and a design for space applications is proposed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [21] Experimental investigation of pulse tube refrigerator with rod type displacer as phase shifter
    Wang, Mingjun
    Xu, Haojie
    Lin, Yuzhe
    Zhang, Zhao
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 93 : 47 - 51
  • [22] Two-stage pulse tube refrigerator with step displacer as phase shifter
    Zhu, Shaowei
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [23] Numerical Study on the Performance Sensitivity of a Pulse Tube Cryocooler with Active Phase Shifter
    Liang, K.
    Abolghasemi, A.
    Stone, C. R.
    Dadd, M. W.
    Bailey, P. B.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [24] ANALYTICAL MODEL FOR A PULSE TUBE CRYOCOOLER BELLOWS PHASE SHIFTER AND EXPERIMENTAL RESULTS
    Cheadle, M. J.
    Nellis, G. F.
    Klein, S. A.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1608 - 1615
  • [25] Experimental investigation on DC flow control in a single-stage pulse tube refrigerator operating below 20K
    Jiang, YL
    Chen, GB
    Thummes, G
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 77 - 80
  • [26] 10K EM pulse tube cooler
    Jaco, C.
    Nguyen, T.
    Colbert, R.
    Raab, J.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 659 - 664
  • [27] A high efficiency coaxial pulse tube cryocooler operating at 60 K
    Wang, Nailiang
    Zhao, Miguang
    Ou, Yangyang
    Zhu, Qianglong
    Wei, Lingjiao
    Chen, Houlei
    Cai, Jinghui
    Liang, Jingtao
    CRYOGENICS, 2018, 93 : 48 - 50
  • [28] Development of a spaceborne pulse tube cooler operating at 170K
    Deng, Weifeng
    Liu, Shaoshuai
    Jiang, Zhenhua
    Ding, Lei
    Wu, Yinong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 1 - 8
  • [29] Modification test of staged pulse tube refrigerator for temperatures below 4 K
    Chen, GB
    Zheng, JY
    Qiu, LM
    Bai, X
    Gan, ZH
    Yan, PD
    Yu, JP
    Jin, T
    Huang, ZX
    CRYOGENICS, 1997, 37 (09) : 529 - 532
  • [30] A thermoacoustically driven pulse tube refrigerator capable of working below 120 K
    Jin, T
    Chen, GB
    Shen, Y
    CRYOGENICS, 2001, 41 (08) : 595 - 601