Innovative phase shifter for pulse tube operating below 10 K

被引:1
|
作者
Duval, Jean-Marc [1 ,2 ]
Charles, Ivan [1 ,2 ]
Daniel, Christophe [3 ]
Andre, Jerome [1 ,2 ]
机构
[1] Univ Grenoble Alpes, INAC SBT, F-38000 Grenoble, France
[2] CEA, INAC SBT, F-38000 Grenoble, France
[3] CNES, 18 Ave Edouard Belin, F-31401 Toulouse 9, France
关键词
Cryocooler; Pulse tube; Diaphragm; Inertance tube;
D O I
10.1016/j.cryogenics.2016.07.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
Stirling type pulse tubes are classically based on the use of an inertance phase shifter to optimize their cooling power. The limitations of the phase shifting capabilities of these inertances have been pointed out in various studies. These limitations are particularly critical for low temperature operation, typically below about 50 K. An innovative phase shifter using an inertance tube filled with liquid, or fluid with high density or low viscosity, and separated by a sealed metallic diaphragm has been conceived and tested. This device has been characterized and validated on a dedicated test bench. Operation on a 50-80 K pulse tube cooler and on a low temperature (below 8 K) pulse tube cooler have been demonstrated and have validated the device in operation. These developments open the door for efficient and compact low temperature Stirling type pulse tube coolers. The possibility of long life operation has been experimentally verified and a design for space applications is proposed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [31] Design and analysis of compact work-recovery phase shifter for pulse tube refrigerator
    Ki, Taekyung
    Jeong, Sangkwon
    CRYOGENICS, 2012, 52 (2-3) : 105 - 110
  • [32] Numerical investigation of the new phase shifter for pulse tube refrigerator - inertance tube combining with step-piston
    Lin, Yuzhe
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 42 - 48
  • [33] Numerical Study of a 10 K Two Stage Pulse Tube Cryocooler with Precooling Inside the Pulse Tube
    Pang, Xiaomin
    Wang, Xiaotao
    Dai, Wei
    Hu, Jianyin
    Luo, Ercang
    26TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE & INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2016, 2017, 171
  • [34] 10 K high frequency pulse tube cryocooler with precooling
    Liu, Sixue
    Chen, Liubiao
    Wu, Xianlin
    Zhou, Yuan
    Wang, Junjie
    CRYOGENICS, 2016, 77 : 15 - 19
  • [35] AN ACHROMATIC PHASE-SHIFTER OPERATING ON THE GEOMETRIC PHASE
    HARIHARAN, P
    CIDDOR, PE
    OPTICS COMMUNICATIONS, 1994, 110 (1-2) : 13 - 17
  • [36] An efficient high cooling-capacity 40 K pulse tube refrigerator using an active dual-piston as phase shifter
    Hui, Hejun
    Song, Jiantang
    Yin, Wang
    Ding, Lei
    Liu, Shaoshuai
    Jiang, Zhenhua
    Zhu, Haifeng
    Wu, Yinong
    ENERGY, 2024, 286
  • [37] A high efficiency Stirling/pulse tube hybrid cryocooler operating at 35 K/85 K
    Liu, Biqiang
    Jiang, Zhenhua
    Ying, Kongkuai
    Zhu, Haifeng
    Liu, Shaoshuai
    Wen, Fengshuo
    Wu, Yinong
    Dong, Deping
    CRYOGENICS, 2019, 101 : 137 - 140
  • [38] Development of recuperator for 4 K pulse tube refrigerators operating at opposite phases
    Jung, J
    Jeong, S
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1584 - 1591
  • [39] Impact of operating parameters on 80 K pulse tube cryocoolers for space applications
    Liu, Shaoshuai
    Jiang, Zhenhua
    Ding, Lei
    Zhu, Haifeng
    Huang, Qi
    Wu, Yinong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 226 - 233
  • [40] A 3He pulse tube cooler operating down to 1.3 K
    Jiang, N
    Lindemann, U
    Giebeler, F
    Thummes, G
    CRYOGENICS, 2004, 44 (11) : 809 - 816