Enhanced joint spectral and time domain optical coherence tomography for quantitative flow velocity measurement

被引:4
|
作者
Walther, Julia [1 ]
Koch, Edmund [1 ]
机构
[1] Tech Univ Dresden, Dept Clin Sensoring & Monitoring, Fac Med Carl Gustav Carus, Dresden, Germany
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V | 2011年 / 8091卷
关键词
spectral domain optical coherence tomography; phase-resolved Doppler analysis; flow measurement; oblique sample motion; advanced interferometry; non-invasive imaging technique; random scattering sample; BLOOD-FLOW; TRANSVERSE; MOTION; OCT;
D O I
10.1117/12.889685
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, a new method called joint spectral and time domain optical coherence tomography (STdOCT) for flow velocity measurement in spectral domain OCT (SD OCT) was presented. This method analyzes the detected time-resolved interference fringe spectra by using a two-dimensional fast Fourier transformation (2D FFT) to determine directly the Doppler frequency shift instead of calculating the phase difference at each depth position of adjacent A-scans. There, it was found that STdOCT is more robust for measurements with low signal to noise ratio than the classic phase-resolved Doppler OCT (DOCT) making it attractive first for imaging fast flow velocities at which a strong Doppler angle dependent signal damping occurs due to interference fringe washout and second for investigating large blood vessels with a big diameter and a highly damped signal of blood with increasing depth due to strong scattering and absorption in the near-infrared wavelength range. In the present study, we would like to introduce an enhanced algorithm for STdOCT permitting a more precise flow velocity measurement in comparison to the conventional STdOCT. The new method determines the amplitude of the broadened Doppler frequency shift by calculating the center of gravity via the complex analytical signal as a result of the second FFT instead of detecting the maximum intensity signal. Furthermore, the comparison with phase-resolved DOCT was done experimentally by using a flow phantom consisting of a 1% Intralipid emulsion and a 320 mu m glass capillary. As a result, the enhanced STdOCT and DOCT processed data are completely equivalent.
引用
收藏
页数:7
相关论文
共 50 条
  • [42] Measurement of total velocity components of particle flow with optical coherence tomography
    Zhou, Hongxian
    Ma, Zhenhe
    Wang, Yi
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XII, 2015, 9322
  • [43] Retinal flow velocity measurement using optical coherence tomography angiography
    Fard, Ali
    Rikhter, Dmitry
    Sha, Patricia
    Wei, Wei
    Zhang, Qinqin
    Wang, Ruikang K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [44] Visualization and measurement of capillary-driven blood flow using spectral domain optical coherence tomography
    Cito, Salvatore
    Ahn, Yeh-Chan
    Pallares, Jordi
    Duarte, Rodrigo Martinez
    Chen, Zhongping
    Madou, Marc
    Katakis, Ioanis
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (02) : 227 - 237
  • [45] Visualization and measurement of capillary-driven blood flow using spectral domain optical coherence tomography
    Salvatore Cito
    Yeh-Chan Ahn
    Jordi Pallares
    Rodrigo Martinez Duarte
    Zhongping Chen
    Marc Madou
    Ioanis Katakis
    Microfluidics and Nanofluidics, 2012, 13 : 227 - 237
  • [46] Multirate Spectral Domain Optical Coherence Tomography
    Gaur, Prabhav
    Grieco, Andrew
    Fainman, Yeshaiahu
    IEEE PHOTONICS JOURNAL, 2023, 15 (05):
  • [47] Spectral domain optical coherence tomography interpretation
    Blacklaws, Jake
    Seamone, Mark E.
    Gupta, R. Rishi
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 181 (05) : 710 - 710
  • [48] Simultaneous complex ambiguity removal and quantitative flow velocity estimation with joint Spectral and Time domain OCT
    Szkulmowski, Maciej
    Grulkowski, Ireneusz
    Szlag, Daniel
    Szkulmowska, Anna
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168
  • [49] The linear artifact in enhanced depth imaging spectral domain optical coherence tomography
    Chengguo Zuo
    Lan Mi
    Shasha Yang
    Xinxing Guo
    Hui Xiao
    Xing Liu
    Scientific Reports, 7
  • [50] The linear artifact in enhanced depth imaging spectral domain optical coherence tomography
    Zuo, Chengguo
    Mi, Lan
    Yang, Shasha
    Guo, Xinxing
    Xiao, Hui
    Liu, Xing
    SCIENTIFIC REPORTS, 2017, 7