Enhanced joint spectral and time domain optical coherence tomography for quantitative flow velocity measurement

被引:4
|
作者
Walther, Julia [1 ]
Koch, Edmund [1 ]
机构
[1] Tech Univ Dresden, Dept Clin Sensoring & Monitoring, Fac Med Carl Gustav Carus, Dresden, Germany
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V | 2011年 / 8091卷
关键词
spectral domain optical coherence tomography; phase-resolved Doppler analysis; flow measurement; oblique sample motion; advanced interferometry; non-invasive imaging technique; random scattering sample; BLOOD-FLOW; TRANSVERSE; MOTION; OCT;
D O I
10.1117/12.889685
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, a new method called joint spectral and time domain optical coherence tomography (STdOCT) for flow velocity measurement in spectral domain OCT (SD OCT) was presented. This method analyzes the detected time-resolved interference fringe spectra by using a two-dimensional fast Fourier transformation (2D FFT) to determine directly the Doppler frequency shift instead of calculating the phase difference at each depth position of adjacent A-scans. There, it was found that STdOCT is more robust for measurements with low signal to noise ratio than the classic phase-resolved Doppler OCT (DOCT) making it attractive first for imaging fast flow velocities at which a strong Doppler angle dependent signal damping occurs due to interference fringe washout and second for investigating large blood vessels with a big diameter and a highly damped signal of blood with increasing depth due to strong scattering and absorption in the near-infrared wavelength range. In the present study, we would like to introduce an enhanced algorithm for STdOCT permitting a more precise flow velocity measurement in comparison to the conventional STdOCT. The new method determines the amplitude of the broadened Doppler frequency shift by calculating the center of gravity via the complex analytical signal as a result of the second FFT instead of detecting the maximum intensity signal. Furthermore, the comparison with phase-resolved DOCT was done experimentally by using a flow phantom consisting of a 1% Intralipid emulsion and a 320 mu m glass capillary. As a result, the enhanced STdOCT and DOCT processed data are completely equivalent.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Selected Clinical Comparisons of Spectral Domain and Time Domain Optical Coherence Tomography
    Luviano, Damien M.
    Benz, Matthew S.
    Kim, Rosa Y.
    Fish, Richard H.
    Wong, Tien P.
    Kegley, Eric N.
    Brown, David M.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (03) : 325 - 328
  • [32] Optical coherence tomography in paediatric glaucoma: time domain versus spectral domain
    Ghasia, Fatema F.
    Freedman, Sharon F.
    Rajani, Anand
    Holgado, Sandra
    Asrani, Sanjay
    El-dairi, Mays
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (07) : 837 - 842
  • [33] In vivo burn scar assessment with speckle decorrelation and joint spectral and time domain optical coherence tomography
    Wang, Qiang
    Gong, Peijun
    Afsharan, Hadi
    Joo, Chulmin
    Morellini, Natalie
    Fear, Mark
    Wood, Fiona
    Ho, Hao
    Silva, Dilusha
    Cense, Barry
    JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (12)
  • [34] Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography
    Kumar, S.
    Verma, Y.
    Sharma, P.
    Shrimali, R.
    Gupta, P. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (01): : 395 - 399
  • [35] Absolute velocity measurement using three-beam spectral-domain Doppler optical coherence tomography
    P. Sharma
    Y. Verma
    S. Kumar
    P. K. Gupta
    Applied Physics B, 2015, 120 : 539 - 543
  • [36] Spectral calibration in spectral domain optical coherence tomography
    Wang, Kai
    Ding, Zhihua
    CHINESE OPTICS LETTERS, 2008, 6 (12) : 902 - 904
  • [37] Spectral calibration in spectral domain optical coherence tomography
    王凯
    丁志华
    ChineseOpticsLetters, 2008, 6 (12) : 902 - 904
  • [38] Absolute velocity measurement using three-beam spectral-domain Doppler optical coherence tomography
    Sharma, P.
    Verma, Y.
    Kumar, S.
    Gupta, P. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 120 (03): : 539 - 543
  • [39] Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography
    S. Kumar
    Y. Verma
    P. Sharma
    R. Shrimali
    P. K. Gupta
    Applied Physics B, 2014, 117 : 395 - 399
  • [40] Blood flow velocity measurement by endovascular Doppler optical coherence tomography
    Sun, Cuiru
    Nolte, Felix
    Barry Vuong
    Cheng, Kyle H. Y.
    Lee, Kenneth K. C.
    Standish, Beau A.
    Courtney, Brian
    Marotta, Thomas R.
    Yang, Victor X. D.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565