Enhanced joint spectral and time domain optical coherence tomography for quantitative flow velocity measurement

被引:4
|
作者
Walther, Julia [1 ]
Koch, Edmund [1 ]
机构
[1] Tech Univ Dresden, Dept Clin Sensoring & Monitoring, Fac Med Carl Gustav Carus, Dresden, Germany
关键词
spectral domain optical coherence tomography; phase-resolved Doppler analysis; flow measurement; oblique sample motion; advanced interferometry; non-invasive imaging technique; random scattering sample; BLOOD-FLOW; TRANSVERSE; MOTION; OCT;
D O I
10.1117/12.889685
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, a new method called joint spectral and time domain optical coherence tomography (STdOCT) for flow velocity measurement in spectral domain OCT (SD OCT) was presented. This method analyzes the detected time-resolved interference fringe spectra by using a two-dimensional fast Fourier transformation (2D FFT) to determine directly the Doppler frequency shift instead of calculating the phase difference at each depth position of adjacent A-scans. There, it was found that STdOCT is more robust for measurements with low signal to noise ratio than the classic phase-resolved Doppler OCT (DOCT) making it attractive first for imaging fast flow velocities at which a strong Doppler angle dependent signal damping occurs due to interference fringe washout and second for investigating large blood vessels with a big diameter and a highly damped signal of blood with increasing depth due to strong scattering and absorption in the near-infrared wavelength range. In the present study, we would like to introduce an enhanced algorithm for STdOCT permitting a more precise flow velocity measurement in comparison to the conventional STdOCT. The new method determines the amplitude of the broadened Doppler frequency shift by calculating the center of gravity via the complex analytical signal as a result of the second FFT instead of detecting the maximum intensity signal. Furthermore, the comparison with phase-resolved DOCT was done experimentally by using a flow phantom consisting of a 1% Intralipid emulsion and a 320 mu m glass capillary. As a result, the enhanced STdOCT and DOCT processed data are completely equivalent.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Flow velocity estimation using joint Spectral and Time Domain Optical Coherence Tomography
    Szkulmowski, Maciej
    Szkulmowska, Anna
    Bajraszewski, Tomasz
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2008, 16 (09): : 6008 - 6025
  • [2] Velocity noise reduction by using enhanced joint spectral and time domain optical coherence tomography
    Walther, Julia
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES VI, 2013, 8802
  • [3] Flow velocity estimation by complex ambiguity free joint Spectral and Time domain Optical Coherence Tomography
    Szkulmowski, Maciej
    Grulkowski, Ireneusz
    Szlag, Daniel
    Szkulmowska, Anna
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2009, 17 (16): : 14281 - 14297
  • [4] True velocity mapping using joint Spectral and Time domain Optical Coherence Tomography
    Grulkowski, Ireneusz
    Szkulmowski, Maciej
    Bukowska, Danuta
    Tamborski, Szymon
    Gorczynska, Iwona
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [5] Three-dimensional quantitative imaging of retinal and choroidal blood flow velocity using joint Spectral and Time domain Optical Coherence Tomography
    Szkulmowska, Anna
    Szkulmowski, Maciej
    Szlag, Daniel
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2009, 17 (13): : 10584 - 10598
  • [6] Spectroscopy by joint Spectral and Time domain Optical Coherence Tomography
    Szkulmowski, Maciej
    Tamborski, Szymon
    Wojtkowski, Maciej
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIX, 2015, 9312
  • [7] Assessment of the flow velocity of blood cells in a microfluidic device using joint spectral and time domain optical coherence tomography
    Bukowska, Danuta M.
    Derzsi, Ladislav
    Tamborski, Szymon
    Szkulmowski, Maciej
    Garstecki, Piotr
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2013, 21 (20): : 24025 - 24038
  • [8] Retinal blood flow analysis using joint spectral and time domain optical coherence tomography
    Szkulmowska, Anna
    Szkuhnowski, Maciej
    Bajraszewski, Tomasz
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPHTHALMIC TECHNOLOGIES XVIII, 2008, 6844
  • [9] Spectral domain optical coherence tomography for embryo heart flow measurement
    Ma Zhenhe
    He Zhonghai
    Zhao Yuqian
    Li Zhigang
    Wu Zhaoxia
    CEIS 2011, 2011, 15
  • [10] Phase unwrapping for Doppler spectral domain optical coherence tomography flow measurement
    Zhao, Yuqian
    Ma, Yushu
    Liu, Jian
    Yu, Yao
    Wang, Yi
    Ma, Zhenhe