Inner diameters of the normal carotid arteries measured using three-dimensional digital subtraction catheter angiography: a retrospective analysis

被引:3
|
作者
Tan, Qingjing [1 ]
Qin, Chao [2 ]
Yang, Junwei [1 ]
Wang, Tianbao [1 ]
Lin, Haohai [1 ]
Lin, Cuiting [2 ]
Chen, Xiangren [2 ]
机构
[1] Guangxi Univ Chinese Med, Dept Neurol, Affiliated Hosp 1, Nanning, Guangxi, Peoples R China
[2] Guangxi Med Univ, Dept Neurol, Affiliated Hosp 1, Nanning, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Carotid arteries; Carotid bifurcation; Internal diameter; Digital subtraction angiography; Essen Stroke Risk Score; STROKE RISK SCORE; MAGNETIC-RESONANCE ANGIOGRAPHY; STENOSIS; ENDARTERECTOMY; VALIDATION; SURGERY; PLAQUE; REPRODUCIBILITY; BIFURCATION; PREVALENCE;
D O I
10.1186/s12883-021-02328-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To obtain normal ranges for the inner diameters of the carotid arteries. Methods This retrospective analysis included consecutive patients with disease-free carotid arteries who had undergone 3D-DSA at two hospitals in Nanning, Guangxi, between March 2013 and March 2018. Demographic and clinical characteristics, including Essen Stroke Risk Score (ESRS), were extracted from the medical records. The 3D-DSA data were used to calculate the inner diameters of the carotid arteries. Results The analysis included 1182 patients (837 males) aged 58.81 +/- 11.02 years. The inner diameters of the proximal carotid sinus (CS), CS bulge, distal CS, and common carotid artery (CCA) were larger on the right than on the left (P < 0.05). The inner diameters of the proximal CS, CS bulge, distal CS, and CCA on both sides were larger for males than females (P < 0.05). The inner diameters of the proximal CS, CS bulge, and distal CS on both sides were smaller for patients aged > 65 years than for patients aged <= 55 years (P < 0.05). Right CCA inner diameter did not vary with age, whereas left CCA inner diameter was larger for patients aged > 55 years than for patients aged <= 45 years (P < 0.05). The inner diameters of the proximal CS, CS bulge, and distal CS on both sides were smaller for patients with ESRS >= 3 than those with ESRS < 3 (P < 0.05). Conclusion This study provides reference values for the internal diameters of normal carotid arteries. Carotid artery diameters varied with side, sex, and age.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation
    Sutton, M.A.
    Ke, X.
    Lessner, S.M.
    Goldbach, M.
    Yost, M.
    Zhao, F.
    Schreier, H.W.
    Journal of Biomedical Materials Research - Part A, 2008, 84 (01) : 178 - 190
  • [42] RAPID aneurysm accurately measures aneurysm size on CT angiography compared to three-dimensional digital subtraction angiography
    Snyder, Sarah J.
    Gauden, Andrew
    Copeland, Karen
    Spiotta, Alejandro M.
    Heit, Jeremy J.
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [43] Three-dimensional fusion digital subtraction angiography: New reconstruction algorithm for simultaneous three-dimensional rendering of osseous and vascular information obtained during rotational angiography
    Gailloud, P
    Oishi, S
    Murphy, K
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (04) : 908 - 911
  • [44] Three-Dimensional Evaluation of Carotid Artery Stenosis Using CT Angiography
    Sheth, Parth
    Henry, Travis
    Veeraswamy, Ravi K.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 138S - 138S
  • [45] Amended Intraoperative Neuronavigation: Three-Dimensional Vascular Roadmapping with Selective Rotational Digital Subtraction Angiography
    Fierstra, Jorn
    Anon, Javier
    Mendelowitsch, Itai
    Fandino, Javier
    Diepers, Michael
    Remonda, Luca
    Marbacher, Serge
    WORLD NEUROSURGERY, 2020, 135 : 183 - 187
  • [46] Usefulness of three-dimensional digital subtraction angiography in endovascular treatment of a spinal dural arteriovenous fistula
    Matsubara, Noriaki
    Miyachi, Shigeru
    Izumi, Takashi
    Ohshima, Tomotaka
    Tsurumi, Auhito
    Hososhimn, Osamu
    Kinkori, Takeshi
    Yoshida, Jun
    JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (05) : 462 - 467
  • [47] Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries
    Levy, RA
    Prince, MR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 211 - 215
  • [48] Three-dimensional contrast-enhanced MR angiography of the extracranial carotid arteries: Two techniques
    Levy, RA
    Maki, JH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (04) : 688 - 690
  • [49] Aortoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography
    Sueyoshi, E
    Sakamoto, I
    Matsuoka, Y
    Ogawa, Y
    Hayashi, H
    Hashmi, R
    Hayashi, K
    RADIOLOGY, 1999, 210 (03) : 683 - 688
  • [50] Preoperative imaging of cervical spine hemangioblastomas using three-dimensional fusion digital subtraction angiography - Report of two cases
    Sciubba, Daniel M.
    Mavinkurve, Gaurav G.
    Gailloud, Philippe
    Garonzik, Ira M.
    Recinos, Pablo F.
    McGirt, Matthew J.
    Woodworth, Graeme F.
    Witham, Timothy
    Khavkin, Yevgeniv
    Gokaslan, Ziya L.
    Wolinsky, Jean-Paul
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (01) : 96 - 100